1712613 ELECTRONICS GP-MACHINE Caterpillar parts
320C, 320C FM, 320C L
Rating:
Alternative (cross code) number:
CA1712613
171-2613
1712613
CA1712613
171-2613
1712613
EXCAVATOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
1573165 1712613 ECU ECM Compatible with Caterpillar E320C 322C 330C 20R-2315 Programmable Shelf Life
YONGHPQ Advanced diagnosis function: integrated with advanced fault diagnosis circuit and software, it can quickly and accurately detect the faults of the motherboard and connected equipment, facilitate maintenance personnel to locate problems and improve maintenance efficiency. || High compatibility: it is suitable for a variety of car models and brands, whether it is a popular model or a niche model, it can be easily installed without worrying about compatibility issues. || High-quality electronic components: high-quality electronic components such as capacitors and resistors are selected, which have the characteristics of low leakage, long life and high stability, greatly improving the overall reliability and durability of the motherboard. || Excellent performance: advanced chipset is adopted, with powerful computing power, which ensures that the automobile computer can run all kinds of complex programs and tasks efficiently. || Accurate clock synchronization: Built-in high-precision clock chip ensures the accuracy of the system clock, makes the components of the automobile computer work more harmoniously, and avoids abnormal program operation caused by clock deviation.
YONGHPQ Advanced diagnosis function: integrated with advanced fault diagnosis circuit and software, it can quickly and accurately detect the faults of the motherboard and connected equipment, facilitate maintenance personnel to locate problems and improve maintenance efficiency. || High compatibility: it is suitable for a variety of car models and brands, whether it is a popular model or a niche model, it can be easily installed without worrying about compatibility issues. || High-quality electronic components: high-quality electronic components such as capacitors and resistors are selected, which have the characteristics of low leakage, long life and high stability, greatly improving the overall reliability and durability of the motherboard. || Excellent performance: advanced chipset is adopted, with powerful computing power, which ensures that the automobile computer can run all kinds of complex programs and tasks efficiently. || Accurate clock synchronization: Built-in high-precision clock chip ensures the accuracy of the system clock, makes the components of the automobile computer work more harmoniously, and avoids abnormal program operation caused by clock deviation.
KoehLy E320C 322C 330C 171-2613 157-3165 20R-2315 1573165 1712613 Compatible with ECU Control Module Unit with Program
KoehLy ECU refers to the electronic control unit in a car that is responsible for managing and controlling different automotive systems. || Real-time performance: ECU requires real-time processing || Power management: Power consumption needs to be considered during design to reduce consumption and extend service life. || It has certain data storage capabilities for storing fault information and running parameters. || Vehicle dynamic control: used for dynamic stability control, traction control and other systems.
KoehLy ECU refers to the electronic control unit in a car that is responsible for managing and controlling different automotive systems. || Real-time performance: ECU requires real-time processing || Power management: Power consumption needs to be considered during design to reduce consumption and extend service life. || It has certain data storage capabilities for storing fault information and running parameters. || Vehicle dynamic control: used for dynamic stability control, traction control and other systems.
ECU Control Module Unit with Program 171-2613 157-3165 20R-2315 Fits for for Caterpillar CAT 312C 315C 318C 319C 320C 321C 322C 325C 330C M325C Excavator
SXCCGMGQ Part Name:ECU Control Module Unit with Program || Part Number:171-2613 157-3165 20R-2315 || Application:Fits for for Caterpillar CAT 312C 315C 318C 319C 320C 321C 322C 325C 330C M325C Excavator || Tips: This Product Requires Programming Code To Be Written. Please Send Us the following information: Engine Nameplate, Machine Serial Number nameplate, ECM Part Number || Attention: Before payment, please confirm that the product part number has been compared to your original equipment and ensure that it is suitable for your machine. If you are unsure if the product is suitable, please contact us and we will match it for you
SXCCGMGQ Part Name:ECU Control Module Unit with Program || Part Number:171-2613 157-3165 20R-2315 || Application:Fits for for Caterpillar CAT 312C 315C 318C 319C 320C 321C 322C 325C 330C M325C Excavator || Tips: This Product Requires Programming Code To Be Written. Please Send Us the following information: Engine Nameplate, Machine Serial Number nameplate, ECM Part Number || Attention: Before payment, please confirm that the product part number has been compared to your original equipment and ensure that it is suitable for your machine. If you are unsure if the product is suitable, please contact us and we will match it for you
Information:
when the generator set is in operation.
LOWER PANEL OPEN
6. Circuit breaker. 7. Potential transformers. 8. Current transformers (three). 9. Fuses (F1, F2 and F3).Circuit breaker (6) is a switch that can be closed or opened to connect or disconnect the generator from the electric system. The switch can be closed or opened when the generator set is either in operation or when it is stopped.Wires from current transformers (8), around the cable or bus risers of each phase from the generator set, connect to selector switch (5) and ammeter (3). These transformers make a reduction in the current from the generator to the ammeter. The indication on the ammeter is the amount of current in either the cable or bus risers from the generator.Wires from the secondary windings of potential transformers (7) connect to frequency meter (2), switch (5) and voltmeter (1). The voltage from these transformers is at the correct level of voltage needed to operate the frequency meter and the voltmeter. The level of the voltage from the potential transformers is in a direct relation with the level of voltage in a phase from the generator set and the indication on the voltmeter is the same as the voltage in the phase.
UPPER PANEL OPEN
5. Ammeter and voltmeter switch (on upper panel). 10. Fuses (F4, F5).The identification on a wire in a circuit, in the switchgear, is either a number and a letter or a letter and a number that is followed by number 1, number 2, number 3, etc. For example 3T1 on the wire (see the wiring diagram) is between the fuse (F3) and the potential transformer (PT2). The wire from (PT2) to Fuse (F5) is 3T2. The wire from (F5), in the same circuit, is 3T3. The identification of the circuit is on the wire, near the wire terminal, anyplace in the switchgear.
BASIC SWITCHGEAR WIRING DIAGRAMSwitchgear With Optional Parts
There are floor-standing switchgears that have many optional parts. The upper panel (door) can have many more gauges and controls added to the standard three gauges and switch.The A.C. voltmeter (1), frequency meter (2), A.C. ammeter (3), voltage adjust rheostat control (14) and the ammeter-voltmeter switch (13) are always parts in the upper panel.The watt-hour meter (4) makes a record of the electric energy that was used. When the generator set is in operation, the record of the electric energy used constantly increases.When the generator set is in operation, the indication on power factor meter (5) is a ratio. The ratio is the difference between the kilowatts from the electric set and the product of 1000 X (times) the indication on the ammeter X (times) the indication on the voltmeter.When the generator set is in operation, the indication on wattmeter (6) is the amount of electric energy from the generator set. When the electric energy from the generator set increases, because of an increase in the electric load, the indication on the wattmeter increases.Synchronizing switch (9) is used to either connect synchroscope (7) and synchronizing lights
LOWER PANEL OPEN
6. Circuit breaker. 7. Potential transformers. 8. Current transformers (three). 9. Fuses (F1, F2 and F3).Circuit breaker (6) is a switch that can be closed or opened to connect or disconnect the generator from the electric system. The switch can be closed or opened when the generator set is either in operation or when it is stopped.Wires from current transformers (8), around the cable or bus risers of each phase from the generator set, connect to selector switch (5) and ammeter (3). These transformers make a reduction in the current from the generator to the ammeter. The indication on the ammeter is the amount of current in either the cable or bus risers from the generator.Wires from the secondary windings of potential transformers (7) connect to frequency meter (2), switch (5) and voltmeter (1). The voltage from these transformers is at the correct level of voltage needed to operate the frequency meter and the voltmeter. The level of the voltage from the potential transformers is in a direct relation with the level of voltage in a phase from the generator set and the indication on the voltmeter is the same as the voltage in the phase.
UPPER PANEL OPEN
5. Ammeter and voltmeter switch (on upper panel). 10. Fuses (F4, F5).The identification on a wire in a circuit, in the switchgear, is either a number and a letter or a letter and a number that is followed by number 1, number 2, number 3, etc. For example 3T1 on the wire (see the wiring diagram) is between the fuse (F3) and the potential transformer (PT2). The wire from (PT2) to Fuse (F5) is 3T2. The wire from (F5), in the same circuit, is 3T3. The identification of the circuit is on the wire, near the wire terminal, anyplace in the switchgear.
BASIC SWITCHGEAR WIRING DIAGRAMSwitchgear With Optional Parts
There are floor-standing switchgears that have many optional parts. The upper panel (door) can have many more gauges and controls added to the standard three gauges and switch.The A.C. voltmeter (1), frequency meter (2), A.C. ammeter (3), voltage adjust rheostat control (14) and the ammeter-voltmeter switch (13) are always parts in the upper panel.The watt-hour meter (4) makes a record of the electric energy that was used. When the generator set is in operation, the record of the electric energy used constantly increases.When the generator set is in operation, the indication on power factor meter (5) is a ratio. The ratio is the difference between the kilowatts from the electric set and the product of 1000 X (times) the indication on the ammeter X (times) the indication on the voltmeter.When the generator set is in operation, the indication on wattmeter (6) is the amount of electric energy from the generator set. When the electric energy from the generator set increases, because of an increase in the electric load, the indication on the wattmeter increases.Synchronizing switch (9) is used to either connect synchroscope (7) and synchronizing lights
Caterpillar SIS machinery equipment:
Caterpillar SIS
320C & 320C L Excavators AMC00001-UP (MACHINE) POWERED BY 3066 Engine »
171-2613
ELECTRONICS GP-MACHINE
320C & 320C L Excavators BDC00001-UP (MACHINE) POWERED BY 3066 Engine »
171-2613
ELECTRONICS GP-MACHINE
320C & 320C L Excavators BPR00001-UP (MACHINE) POWERED BY 3066 Engine »
171-2613
ELECTRONICS GP-MACHINE
320C Forest Swing Machine BGB00001-UP (MACHINE) POWERED BY 3066 Engine »
171-2613
ELECTRONICS GP-MACHINE
320C U 320C LU Excavators CLM00001-UP (MACHINE) POWERED BY 3066 Engine »
171-2613
ELECTRONICS GP-MACHINE
320C Excavators HBC00001-UP (MACHINE) POWERED BY 3066 Engine »
171-2613
ELECTRONICS GP-MACHINE
320C & 320C L Excavators MAB00001-UP (MACHINE) POWERED BY 3066 Engine »
171-2613
ELECTRONICS GP-MACHINE
320C U & 320C LU Excavators MAC00001-UP (MACHINE) POWERED BY 3066 Engine »
171-2613
ELECTRONICS GP-MACHINE
320C Forest Machines SAH00001-UP (MACHINE) POWERED BY 3066 Engine »
171-2613
ELECTRONICS GP-MACHINE
320C & 320C L Excavators RAW00001-UP (MACHINE) POWERED BY 3066 Engine »
171-2613
ELECTRONICS GP-MACHINE
320C LRR Excavator GAD00001-UP (MACHINE) POWERED BY 3066 Engine »
171-2613
ELECTRONICS GP-MACHINE
320C & 320C L Excavators GNG00001-UP (MACHINE) POWERED BY 3066 Engine »
171-2613
ELECTRONICS GP-MACHINE
320C L Excavator EAG00001-UP (MACHINE) POWERED BY 3066 Engine »
171-2613
ELECTRONICS GP-MACHINE
320C & 320C L EXCAVATORS AKH00001-UP (MACHINE) POWERED BY 3066 ENGINE »
171-2613
ELECTRONICS GP
320C & 320C L EXCAVATORS AKH00001-UP (MACHINE) POWERED BY 3066 ENGINE »
171-2613
ELECTRONICS GP
Caterpillar parts catalog:
Parts electronics Caterpillar catalog:
1777686
ELECTRONICS GP-MONITOR
312C, 312C L, 315C, 318C, 319C, 320C, 320C FM, 322C, 325C, 330C, 330C L
312C, 312C L, 315C, 318C, 319C, 320C, 320C FM, 322C, 325C, 330C, 330C L
1712619
ELECTRONICS GP-IMPLEMENT
320C, 320C FM, 321C, 322C, 325C
320C, 320C FM, 321C, 322C, 325C
2277726
ELECTRONICS GP-MONITOR
312C, 312C L, 315C, 318C, 319C, 320C, 320C FM, 321C, 322C, 325C, 330C, 330C L
312C, 312C L, 315C, 318C, 319C, 320C, 320C FM, 321C, 322C, 325C, 330C, 330C L
2602101
ELECTRONICS GP-MONITOR
312C, 315C, 318C, 319C, 320C, 322C, 325C, 330C, 330C L
312C, 315C, 318C, 319C, 320C, 322C, 325C, 330C, 330C L
2075262
ELECTRONICS GP-MACHINE
120M, 12M, 140M, 143H, 160M, 16H, 216, 216B, 226B, 228, 232B, 236, 236B, 242B, 247, 247B, 248, 252B, 257B, 267, 267B, 268B, 287, 301.5, 302.5, 303.5, 303.5E, 303E CR, 304.5, 304E, 305.5E, 305E, 307D, ...
120M, 12M, 140M, 143H, 160M, 16H, 216, 216B, 226B, 228, 232B, 236, 236B, 242B, 247, 247B, 248, 252B, 257B, 267, 267B, 268B, 287, 301.5, 302.5, 303.5, 303.5E, 303E CR, 304.5, 304E, 305.5E, 305E, 307D, ...
2602159
ELECTRONICS GP-MONITOR
312C L, 315C, 318C, 320C, 322C, 325C, 330C, 330C L
312C L, 315C, 318C, 320C, 322C, 325C, 330C, 330C L
1777683
ELECTRONICS GP-MONITOR
312C, 312C L, 315C, 318C, 319C, 320C, 320C FM, 322C, 325C, 330C, 330C L
312C, 312C L, 315C, 318C, 319C, 320C, 320C FM, 322C, 325C, 330C, 330C L
2622043
ELECTRONICS GP-COMMUNICATION
120M, 12M, 140M, 14M, 160M, 16M, 312D, 319D, 320C, 320C FM, 320D, 320D L, 320D LRR, 320D RR, 321C, 321D LCR, 323D L, 323D LN, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325D, 325D FM, 325D FM LL, 325...
120M, 12M, 140M, 14M, 160M, 16M, 312D, 319D, 320C, 320C FM, 320D, 320D L, 320D LRR, 320D RR, 321C, 321D LCR, 323D L, 323D LN, 324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325D, 325D FM, 325D FM LL, 325...
1852524
ELECTRONICS GP-MONITOR
312C L, 315C, 318C, 320C, 320C FM, 320C L, 322C, 325C, 330C, 330C L
312C L, 315C, 318C, 320C, 320C FM, 320C L, 322C, 325C, 330C, 330C L
1777689
ELECTRONICS GP-MONITOR
312C, 312C L, 315C, 318C, 319C, 320C, 320C FM, 322C, 325C, 330C, 330C L
312C, 312C L, 315C, 318C, 319C, 320C, 320C FM, 322C, 325C, 330C, 330C L
1712616
ELECTRONICS GP-MONITOR
320C, 320C FM
320C, 320C FM
2131198
ELECTRONICS GP-MACHINE
330C, 330C L, 938G II, 950G II, 962G II, 966G II, 972G II, 980G II, 980H, IT38G II, IT62G II
330C, 330C L, 938G II, 950G II, 962G II, 966G II, 972G II, 980G II, 980H, IT38G II, IT62G II
2323768
ELECTRONICS GP-POWER TRAIN
621G, 623G, 627G, 631G, 637G, 657G
621G, 623G, 627G, 631G, 637G, 657G
2457320
ELECTRONICS GP-MACHINE
924G, 924GZ, 930G, IT28G
924G, 924GZ, 930G, IT28G
3616395
ELECTRONICS GP-MACHINE
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP
2375514
ELECTRONICS GP-POWER TRAIN
725, 730, 735, 740
725, 730, 735, 740
3874534
ELECTRONICS GP-ENGINE
12M 3, 12M 3 AWD, 140M 3, 140M 3 AWD, 160M 3, 160M 3 AWD, 627K, 725C, 966M, 966M XE, 972M, 972M XE
12M 3, 12M 3 AWD, 140M 3, 140M 3 AWD, 160M 3, 160M 3 AWD, 627K, 725C, 966M, 966M XE, 972M, 972M XE
1777686
ELECTRONICS GP-MONITOR
312C, 312C L, 315C, 318C, 319C, 320C, 320C FM, 322C, 325C, 330C, 330C L
312C, 312C L, 315C, 318C, 319C, 320C, 320C FM, 322C, 325C, 330C, 330C L
1648212
ELECTRONICS GP-MONITOR
365B, 365B L
365B, 365B L
2565350
ELECTRONICS GP-MONITOR
773F, 775F, 777F
773F, 775F, 777F
2218827
ELECTRONICS GP-IMPLEMENT
345C, 345C L
345C, 345C L
3118593
ELECTRONICS GP-MONITOR
120M 2, 12M 2, 140M 2, 160M 2
120M 2, 12M 2, 140M 2, 160M 2