1R0729 ELEMENT A-HYD Caterpillar parts
Rating:
Alternative (cross code) number:
CA1R0729
1R-0729
1R0729
CA1R0729
1R-0729
1R0729
Weight: 0.61 pounds 0 kg.
Information:
APPLICATION
HYD OIL
DIA
78.7
mm
FLOW RATE
121
L/min
LENGTH
228.6
mm
TYPE
000000000001
Cross Reference:
ACDelco
PF333,
ALCO FILTER
MD047,
MD701,
BALDWIN
PT66HD,
CASE IH
894797R91,
CATERPILLAR
1R-0729,
1S-9150,
2J-0006,
2J-6,
3F-0801,
3F-801,
4A-0332,
4A-332,
6B-0907,
6B-7897,
6B-8219,
6B-8818,
6B-907,
7B-3000,
7B-7775,
8B-2374,
8B-5755,
8H-0847,
8H-847,
9B-1318,
9B-1319,
9B-2950,
9F-6742,
9H-1318,
CHAMP
LP165,
CLEAN FILTERS
ML407,
COOPERS
AZL078,
COOPERSFIAAM FILTERS
FA4007,
CROSLAND FILTERS
441,
DONIT FILTER
41.11.10,
FIAT
759950,
835320,
FLEETGUARD
LF546,
FRAM
C196PL,
GMC
5574592,
MANN-FILTER
P803,
MOTORCRAFT
EFL203,
P.B.R.
AC3057,
TECNOCAR
OP196,
TEHO
D120,
UNICO FILTER
LE7229,
WIX FILTERS
51165,
51171,
WOODGATE
WGL546,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Killer Filter Replacement for Caterpillar 1R0729 (Pack of 4)
Killer Filter Replaces p/n 1R0729 || Proudly Made in the USA || Manufactured with the highest quality materials available on the market, guaranteed! || Strict Quality Control for a superior product || product may vary from image
Killer Filter Replaces p/n 1R0729 || Proudly Made in the USA || Manufactured with the highest quality materials available on the market, guaranteed! || Strict Quality Control for a superior product || product may vary from image
Fuel Filter 1R-0729 Generator Sets Diesel Filter Element Fuel Water Separator Filter For CAT Loader Excavator (Color : 1R-0729 Filter 1PCS)
XARONF Brand new and high quality. || Made of high quality material, durable and practical to use. || Delicate and exquisite, highly match the equipment. || Solid and durable, long service life. || Easy to install and reliable to use.
XARONF Brand new and high quality. || Made of high quality material, durable and practical to use. || Delicate and exquisite, highly match the equipment. || Solid and durable, long service life. || Easy to install and reliable to use.
Fuel Filter 1R-0729 Generator Sets Diesel Filter Element Fuel Water Separator Filter For CAT Loader Excavator (Color : 1R-0729 Filter 2PCS)
XARONF Brand new and high quality. || Made of high quality material, durable and practical to use. || Delicate and exquisite, highly match the equipment. || Solid and durable, long service life. || Easy to install and reliable to use.
XARONF Brand new and high quality. || Made of high quality material, durable and practical to use. || Delicate and exquisite, highly match the equipment. || Solid and durable, long service life. || Easy to install and reliable to use.
Information:
The EMCP 4 has the following communication connections:
Primary CAN Data Link (CAN 1)
Accessory CAN Data Link (EMCP 4.2 only) (CAN 2)
Modbus RTU (RS-485 Half duplex)-SCADA Data Link (EMCP 4.2 only)
RS-485 SCADA Data Link (Modbus RTU, Half Duplex) (EMCP 4.2 only)Primary CAN Data Link (CAN 1)
A communications connection, utilizing CAN 1, is available on the module. The communications connection allows configuration of set points, flashing of the core software, and language text files. The configuration software has password protection for different authorization levels. Configuration of set points will also be possible using the controls on the module. Configuration of set points is made possible by utilizing the same password strategy used across the control system range.The connection will also be utilized for communicating with the engine control module (ECM) using the CAN protocol.This connection will also be utilized for communicating with automatic voltage regulators (AVR) using the CAN protocol when the AVR support this protocol. An example of an AVR is the Caterpillar Digital Voltage Regulator (CDVR).This connection also provides communications for on-package expansion thermocouple modules for use with monitoring of engine temperatures.This connection will also provide communications for the Caterpillar Clean Emissions Module System.The primary CAN communication wires are brought out of the EMCP 4 as part of the 70-pin connector. The pins, as designated on the EMCP 4 connector, are shown in Table 1.
Table 1
Primary CAN Communication Wires
Pin # Name Description
34 CAN 1 - Differential (-) for CAN
42 CAN 1 SH Shield for CAN
50 CAN 1 + Differential (+) for CAN The primary CAN data link consists of a main trunk and small drops.
The maximum allowable trunk length is 40 m (130 ft), and the maximum drop length is 1 m (3 ft).
The CAN network requires a 120 ohm termination resistor on the extreme ends of the main trunk.Accessory CAN Data Link (CAN 2)
Note: The accessory CAN data link (CAN2) is supported only by EMCP 4.2.An accessory data link connection is provided for use with the local and remote, fixed output annunciator options. This connection can be at a distance of up to 250 m (800 ft) from the control module. The connection will support a maximum of four CAN annunciators modules. This data link is for Caterpillar approved modules only.A connection is provided for use with the digital expansion input/output modules.A connection is provided for use with the generator Thermocouple and RTD modules.The total number of optional modules should not exceed four annunciators, four I/O modules, and two temperature modules. Table 2 lists the supported modules for the CAN 1 and CAN 2 datalinks.
Table 2
Module EMCP 4.2
Primary CAN 1 Accessory CAN 2
Electronic Engine Controller 1 0
CDVR 1 0
Annunciator 0 4
Thermocouple 1 1
RTD 0 1
DIO 0 4 The accessory CAN communication wires are brought out of the EMCP 4.2 as part of the 70-pin connector. The pins, as designated on the EMCP 4 connector, are shown in Table 3
Table 3
Accessory CAN Communications Wires
Pin # Name Description
64 CAN 2 - Differential (-) for CAN
63 CAN 2 SH Shield
Primary CAN Data Link (CAN 1)
Accessory CAN Data Link (EMCP 4.2 only) (CAN 2)
Modbus RTU (RS-485 Half duplex)-SCADA Data Link (EMCP 4.2 only)
RS-485 SCADA Data Link (Modbus RTU, Half Duplex) (EMCP 4.2 only)Primary CAN Data Link (CAN 1)
A communications connection, utilizing CAN 1, is available on the module. The communications connection allows configuration of set points, flashing of the core software, and language text files. The configuration software has password protection for different authorization levels. Configuration of set points will also be possible using the controls on the module. Configuration of set points is made possible by utilizing the same password strategy used across the control system range.The connection will also be utilized for communicating with the engine control module (ECM) using the CAN protocol.This connection will also be utilized for communicating with automatic voltage regulators (AVR) using the CAN protocol when the AVR support this protocol. An example of an AVR is the Caterpillar Digital Voltage Regulator (CDVR).This connection also provides communications for on-package expansion thermocouple modules for use with monitoring of engine temperatures.This connection will also provide communications for the Caterpillar Clean Emissions Module System.The primary CAN communication wires are brought out of the EMCP 4 as part of the 70-pin connector. The pins, as designated on the EMCP 4 connector, are shown in Table 1.
Table 1
Primary CAN Communication Wires
Pin # Name Description
34 CAN 1 - Differential (-) for CAN
42 CAN 1 SH Shield for CAN
50 CAN 1 + Differential (+) for CAN The primary CAN data link consists of a main trunk and small drops.
The maximum allowable trunk length is 40 m (130 ft), and the maximum drop length is 1 m (3 ft).
The CAN network requires a 120 ohm termination resistor on the extreme ends of the main trunk.Accessory CAN Data Link (CAN 2)
Note: The accessory CAN data link (CAN2) is supported only by EMCP 4.2.An accessory data link connection is provided for use with the local and remote, fixed output annunciator options. This connection can be at a distance of up to 250 m (800 ft) from the control module. The connection will support a maximum of four CAN annunciators modules. This data link is for Caterpillar approved modules only.A connection is provided for use with the digital expansion input/output modules.A connection is provided for use with the generator Thermocouple and RTD modules.The total number of optional modules should not exceed four annunciators, four I/O modules, and two temperature modules. Table 2 lists the supported modules for the CAN 1 and CAN 2 datalinks.
Table 2
Module EMCP 4.2
Primary CAN 1 Accessory CAN 2
Electronic Engine Controller 1 0
CDVR 1 0
Annunciator 0 4
Thermocouple 1 1
RTD 0 1
DIO 0 4 The accessory CAN communication wires are brought out of the EMCP 4.2 as part of the 70-pin connector. The pins, as designated on the EMCP 4 connector, are shown in Table 3
Table 3
Accessory CAN Communications Wires
Pin # Name Description
64 CAN 2 - Differential (-) for CAN
63 CAN 2 SH Shield
Parts element Caterpillar catalog:
1R0727
ELEMENT A-OIL
Caterpillar
Caterpillar
1R0723
ELEMENT AS-HYD
Caterpillar
Caterpillar
1R0721
ELEMENT AS
Caterpillar
Caterpillar
1Q1688
ELEMENT AS-
Caterpillar
Caterpillar
1N4409
ELEMENT A
Caterpillar
Caterpillar
1M9156
ELEMENT A.
Caterpillar
Caterpillar
1R0794
ELEMENT AS
Caterpillar
Caterpillar
1R0789
ELEMENT AS.
Caterpillar
Caterpillar
1R0783
ELEMENT AS-
Caterpillar
Caterpillar
1R0746
ELEMENT AS-HYD
Caterpillar
Caterpillar
1R0733
ELEMENT AS-
Caterpillar
Caterpillar
1R0730
ELEMENT OIL
Caterpillar
Caterpillar