1R0746 ELEMENT AS-HYD Caterpillar parts
Rating:
Alternative (cross code) number:
CA1R0746
1R-0746
1R0746
CA1R0746
1R-0746
1R0746
Weight: 0.35 pounds 0 kg.
Information:
APPLICATION
HYD OIL
DIA
73
mm
FLOW RATE
65
L/min
LENGTH
143
mm
TYPE
000000000001
Cross Reference:
CATERPILLAR
1R0746,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
1R0730 1R-0730 1R0746 1R-0746 XH453 Return Hydraulic Oil Filter (H-0746)
Generic 1R0730 1R-0730 1R0746 1R-0746 XH453 Return Hydraulic Oil Filter
Generic 1R0730 1R-0730 1R0746 1R-0746 XH453 Return Hydraulic Oil Filter
Replacement For 1R0730 1R0746 2P5834 Filter Fits Caterpillar (Fits CAT)
Amhillras Replacement For 1R0730 1R0746 2P5834 Filter Fits Caterpillar (Fits CAT)
Amhillras Replacement For 1R0730 1R0746 2P5834 Filter Fits Caterpillar (Fits CAT)
Information:
The EMCP 4 can be used for monitoring and control of Mechanical Unit Injector (MUI) engines. With the absence of an engine ECM, the EMCP 4 uses relay outputs to control the start/stop function and the analog inputs for the monitoring of critical engine parameters.Reference: For EMCP 4 configuration settings that are specific to applications that use a MUI engine, refer to Testing and Adjusting, "Electronic Control Module (Generator Set) - Configure".MUI engine start/stop control by EMCP 4:
Relay output 1 (configurable) typically used to energize the switch for the starter the magnetic switch on the starter motor that is used to crank the engine.
Relay output 2 (configurable) typically used to provide a run signal to the engine governor.
More relay output (configured for rated speed) gives permissive signal to the engine governor to ramp up to rated speed.MUI engine parameters monitored directly by EMCP 4:
Engine Speed (via magnetic pickup input)The EMCP 4.2 has three analog inputs. For a MUI engine analog input 1 and analog input 2 are set at the factory and are not available for customer use, analog input 3 may be available for customer use.
Oil Pressure (via analog input 1)
Coolant Temperature (via analog input 2)
Relay output 1 (configurable) typically used to energize the switch for the starter the magnetic switch on the starter motor that is used to crank the engine.
Relay output 2 (configurable) typically used to provide a run signal to the engine governor.
More relay output (configured for rated speed) gives permissive signal to the engine governor to ramp up to rated speed.MUI engine parameters monitored directly by EMCP 4:
Engine Speed (via magnetic pickup input)The EMCP 4.2 has three analog inputs. For a MUI engine analog input 1 and analog input 2 are set at the factory and are not available for customer use, analog input 3 may be available for customer use.
Oil Pressure (via analog input 1)
Coolant Temperature (via analog input 2)
Parts element Caterpillar catalog:
1R0733
ELEMENT AS-
Caterpillar
Caterpillar
1R0730
ELEMENT OIL
Caterpillar
Caterpillar
1R0729
ELEMENT A-HYD
Caterpillar
Caterpillar
1R0727
ELEMENT A-OIL
Caterpillar
Caterpillar
1R0723
ELEMENT AS-HYD
Caterpillar
Caterpillar
1R0721
ELEMENT AS
Caterpillar
Caterpillar
1R6355
ELEMENT
Caterpillar
Caterpillar
1R6037
ELEMENT
Caterpillar
Caterpillar
1R1802
ELEMENT AS.-
Caterpillar
Caterpillar
1R0794
ELEMENT AS
Caterpillar
Caterpillar
1R0789
ELEMENT AS.
Caterpillar
Caterpillar
1R0783
ELEMENT AS-
Caterpillar
Caterpillar