1306343 ENGINE AR-PRIMARY Caterpillar parts
M315
Rating:
Alternative (cross code) number:
CA1306343
130-6343
1306343
CA1306343
130-6343
1306343
Weight: 954 pounds 433 kg.
WHEELED EXCAVATOR,
Related part:
1306343
ENGINE AR-BASIC
10R2480
R
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$72.10
13 Oct 2020
-: -
GASKET SET - BOTTOM FOR HYSTER: 1306343
HYSTER || All Brand new & rebuilt items comes with 1 year warranty. || GASKET SET - BOTTOM. Category: HYSTER FORKLIFT PARTS. This part can also be found under the following part numbers: HY1306343 1306343 Â HYSTER 1306343 Â HYSTER1306343 1306343 Â Â . All Brand new & rebuilt items comes with 1 year warranty.
HYSTER || All Brand new & rebuilt items comes with 1 year warranty. || GASKET SET - BOTTOM. Category: HYSTER FORKLIFT PARTS. This part can also be found under the following part numbers: HY1306343 1306343 Â HYSTER 1306343 Â HYSTER1306343 1306343 Â Â . All Brand new & rebuilt items comes with 1 year warranty.
Compatible equipment models: 1306343:
Information:
If replacement of a component is necessary or repair to a component is necessary, the refrigerant in the system must be recovered. Also, if the system has lost any charge after a long period of time, the refrigerant in the system must be recovered. It is necessary to perform the evacuating procedure to delete the system of all air and moisture. You must run the pump for 90 minutes in order to remove water vapor. Also, you must run the pump for 90 minutes in order to attain the vacuum that is listed in Table 1. A complete charge must never be given to a system without first performing the evacuating procedure. Before you evacuate the system, refer to the following manual.
Testing and Adjusting, "Refrigerant Leakage - Test"
Testing and Adjusting, "Refrigerant Recovery"
Testing and Adjusting, "Refrigerant Compressor Oil - Check"If the system has been left open for more than 1/2 hour, the system has been exposed to air and to moisture. Therefore, a new receiver-dryer, an in-line dryer or a desiccant accumulator needs to be installed. Moisture will combine with metals in the refrigerant system. This will produce highly corrosive by-products. The by-products are oxides, iron hydroxide and aluminum hydroxide. Moisture can freeze the expansion valve and moisture can freeze the orifice tube. If there is water in the system, the water must be removed by pulling a vacuum and boiling the water for 90 minutes. Refer to Table 1 that is shown below.
Table 1
Boiling Point of Water Under Vacuum
Temperature of Work Area (°C (°F)) Vacuum That Is Required In Order To Boil Water In An Air Conditioning System (m bar (Hg))
38 (100) 948 (28.0)
32 (90) 965 (28.5)
27 (80) 975 (28.8)
21 (70) 988 (29.2)
All refrigerant must be recovered before the evacuating procedure is started. Never discharge the refrigerant through the vacuum pump.
Flow Chart for the Evacuation Process
Illustration 1 g00476489Installing the Manifold Gauge Set (Evacuation)
Illustration 2 g00469391
(1) Low pressure valve
(2) High pressure valve
(3) Low pressure hose
(4) High pressure hose
(5) Service valve (low pressure side)
(6) Charging hose
(7) Vacuum pump
(8) Service valve (high pressure
Testing and Adjusting, "Refrigerant Leakage - Test"
Testing and Adjusting, "Refrigerant Recovery"
Testing and Adjusting, "Refrigerant Compressor Oil - Check"If the system has been left open for more than 1/2 hour, the system has been exposed to air and to moisture. Therefore, a new receiver-dryer, an in-line dryer or a desiccant accumulator needs to be installed. Moisture will combine with metals in the refrigerant system. This will produce highly corrosive by-products. The by-products are oxides, iron hydroxide and aluminum hydroxide. Moisture can freeze the expansion valve and moisture can freeze the orifice tube. If there is water in the system, the water must be removed by pulling a vacuum and boiling the water for 90 minutes. Refer to Table 1 that is shown below.
Table 1
Boiling Point of Water Under Vacuum
Temperature of Work Area (°C (°F)) Vacuum That Is Required In Order To Boil Water In An Air Conditioning System (m bar (Hg))
38 (100) 948 (28.0)
32 (90) 965 (28.5)
27 (80) 975 (28.8)
21 (70) 988 (29.2)
All refrigerant must be recovered before the evacuating procedure is started. Never discharge the refrigerant through the vacuum pump.
Flow Chart for the Evacuation Process
Illustration 1 g00476489Installing the Manifold Gauge Set (Evacuation)
Illustration 2 g00469391
(1) Low pressure valve
(2) High pressure valve
(3) Low pressure hose
(4) High pressure hose
(5) Service valve (low pressure side)
(6) Charging hose
(7) Vacuum pump
(8) Service valve (high pressure
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts engine Caterpillar catalog:
1079665
ENGINE AR-PRIMARY
M312, M315
M312, M315
1599213
ENGINE AR-PRIMARY
216, 228
216, 228
1865801
ENGINE AR
320B
320B
1539100
ENGINE AR
3412E
3412E
1699621
ENGINE AR
G3516
G3516
1599313
ENGINE AR
G3516
G3516
1699623
ENGINE AR
G3512
G3512
1599312
ENGINE AR
G3512
G3512