Illustration 11 g03339033
"Download successful" window
Wait approximately 30 seconds for the firmware file to be flashed on to the Automation ICM. When successful, a "Download successful" window will appear. Select the "OK" button.
Illustration 12 g03369728
(20) "Verify" button
Select "Verify" button (20) on the RS232 window.
"Verify successful" should appear if the verify process was successful. Select "OK".
Select software file for PLC1 and select "Open" (19). Selecting "Open" (19) will verify the software on PLC1 with the file that was installed.
Illustration 13 g03339037
"Status: Running" window
(21) "OK" button
Select "Run" button (12). A "Status: Running" window will appear confirming the PLC status.
Select "OK" button (21). Note: The procedure to flash PLC2 must follow immediately after the programming of PLC1.Program PLC2
Illustration 14 g03339016
(3) Laptop computer
(4) 327-0375 Adapter Kit
(5) 351-1148 Automation ICM PLC2 Programming Adapter
(6) 351-1148 Automation ICM Service Port Adaptor
(7) Automation ICM
Connect the laptop computer and the Automation ICM as shown in Illustration 14. Note: Laptops with an RS232 serial port can omit adapter kit (4) and connect laptop computer (3) directly to Automation ICM PLC programming adapter (5).
Select "Download" (11).
Browse to and select PLC2 firmware (18) and then select "Open" (19).
Communications to PLC2 are confirmed when the confirmation window appears. Select "OK" . Update PLC2 Operating System
Select "Download" button (11).
Illustration 15 g03339031
File selection window
(17) PLC 1 firmware
(18) PLC 2 firmware
(19) "Open" button
Select new PLC2 firmware (18) and then select "Open" button (19).
Illustration 16 g03339033
"Download successful" window
Wait approximately 30 seconds for the firmware file to be flashed on to the Automation ICM. When successful, a "Download successful" window will appear. Select the "OK" button. Update PLC2 Firmware File
Select "Download" button (11).
Illustration 17 g03339031
File selection window
(17) PLC 1 firmware
(18) PLC 2 firmware
(19) "Open" button
Select PLC2 firmware (18) and then select "Open" button (19).
Illustration 18 g03339033
"Download successful" window
Wait approximately 30 seconds for the firmware file to be flashed on to the Automation ICM. When successful, a "Download successful" window will appear. Select the "OK" button.
Illustration 19 g03369728
(20) "Verify" button
Select "Verify" button (20).
"Verify successful" should appear if the verify process was successful. Select "OK".
Select software file for PLC2 and select "Open" (19). Selecting "Open" (19) will verify the software on PLC2 with the file that was installed.
Illustration 20 g03339037
"Status: Running" window
(21) "OK" button
Select "Run" button (12). A "Status: Running" window will appear confirming the PLC status. Select "OK" button (21).
Select "Exit" button (14) to close the program.
Remove the programming cables.
Replace cover (2). Replace security screws (1) using 9U-7291 Ratcheting Screwdriver and 351-1151 Posthex bit Tool.
Move the battery disconnect switch to the OFF position.
Wait 10 seconds then move the battery disconnect switch to the ON position.