2707235 ENGINE AR-CORE Caterpillar parts
573, C7
Rating:
Alternative (cross code) number:
CA2707235
270-7235
2707235
CA2707235
270-7235
2707235
INDUSTRIAL ENGINE, WHEEL FELLER BUNCHER,
Related part:
2707235
SHORT BLOCK
10R4134
R
2707235
LONG BLOCK
20R3156
R
This part in 7 request:
Show.
This information for suppliers only!
2021-08-19
2020-04-06
2019-05-03
2019-05-03
2019-03-31
2019-03-22
2016-12-20
Information:
Description
Illustration 1 g01283394
(1) APC Hinged Panel (2) Board for the APS ControllerThe board (APC) (2) is located on the front hinged APC panel of the cabinet for the Flywheel. The controller (2) has the following functions:
Provision of resources to allow control of the system processor, FPGA, DSP, related memory devices, and configuration devices
Receiving, scaling, and processing analog telemetry information from the system that is being controlled
Provision of data channels to receive information from satellite boards in the system
Provision of data channels to send information to satellite boards in the system
Provision of communication to users or other systems via RS-232/422, Ethernet, modem, and CAN
Storage of calibration data and configuration data
Tracking of the date and timeEvery 5 years replace the battery. The battery (B1) is a CR2032 Lithium.
Illustration 2 g01411916
APC Board
Illustration 3 g01411927
Left Side Connections for the APC BoardRemoval Procedure
Refer to Systems Operation, Testing and Adjusting, RENR7654, "Internal Component Preremoval Steps (Flywheel Cabinet)" in order to shut down the system and gain access to internal components.
Electrostatic discharge can damage integrated circuits or semiconductors if you touch bus connector pins. When not in use, keep the module in the static-shield bag. Follow these guidelines when you handle any module:Touch a grounded object to discharge static potential.Wear an approved wrist-strap grounding device.Do not touch the bus connector or connector pins.Do not touch circuit components inside the module.If available, use a static-safe work station.
Disconnect all connectors from the board (2). Verify each connector in order to make sure that the label is present and legible. Verify the labeling of each connector with the location of the connector. Refer to Illustration 2.
Remove the seven screws from the edges of the board.
Remove the two nuts from the upper two corners of the board.Installation Procedure
Electrostatic discharge can damage integrated circuits or semiconductors if you touch bus connector pins. When not in use, keep the module in the static-shield bag. Follow these guidelines when you handle any module:Touch a grounded object to discharge static potential.Wear an approved wrist-strap grounding device.Do not touch the bus connector or connector pins.Do not touch circuit components inside the module.If available, use a static-safe work station.
Position the board (2) in the cabinet over the two threaded standoffs at the top two corners of the board.
Install the seven screws onto the remaining standoffs around the edges of the board.
Connect the wire connectors. Verify the labeling of each connector for proper placement. Refer to Illustration 2.
Set the date of installation for each flywheel bearing. The date can be set in the UPSView display. Note: Retrieve the following information from service records.
Devices > CS_HV 1 / 2 / (3 / 4)
Op. Params > Op. Group 5: > A / B Bearing Install Day
Op. Params > Op. Group 5: > A / B Bearing Install Month
Op. Params > Op. Group 5: > A / B Bearing Install Year
Calibrate the board (2). DC Bus Open
Refer to Systems Operation, Testing and Adjusting, RENR7654, "Flywheel Load Cell - Calibrate" and Systems Operation, Testing and Adjusting, RENR7654, "Flywheel DC Bus Current - Calibrate".
Illustration 1 g01283394
(1) APC Hinged Panel (2) Board for the APS ControllerThe board (APC) (2) is located on the front hinged APC panel of the cabinet for the Flywheel. The controller (2) has the following functions:
Provision of resources to allow control of the system processor, FPGA, DSP, related memory devices, and configuration devices
Receiving, scaling, and processing analog telemetry information from the system that is being controlled
Provision of data channels to receive information from satellite boards in the system
Provision of data channels to send information to satellite boards in the system
Provision of communication to users or other systems via RS-232/422, Ethernet, modem, and CAN
Storage of calibration data and configuration data
Tracking of the date and timeEvery 5 years replace the battery. The battery (B1) is a CR2032 Lithium.
Illustration 2 g01411916
APC Board
Illustration 3 g01411927
Left Side Connections for the APC BoardRemoval Procedure
Refer to Systems Operation, Testing and Adjusting, RENR7654, "Internal Component Preremoval Steps (Flywheel Cabinet)" in order to shut down the system and gain access to internal components.
Electrostatic discharge can damage integrated circuits or semiconductors if you touch bus connector pins. When not in use, keep the module in the static-shield bag. Follow these guidelines when you handle any module:Touch a grounded object to discharge static potential.Wear an approved wrist-strap grounding device.Do not touch the bus connector or connector pins.Do not touch circuit components inside the module.If available, use a static-safe work station.
Disconnect all connectors from the board (2). Verify each connector in order to make sure that the label is present and legible. Verify the labeling of each connector with the location of the connector. Refer to Illustration 2.
Remove the seven screws from the edges of the board.
Remove the two nuts from the upper two corners of the board.Installation Procedure
Electrostatic discharge can damage integrated circuits or semiconductors if you touch bus connector pins. When not in use, keep the module in the static-shield bag. Follow these guidelines when you handle any module:Touch a grounded object to discharge static potential.Wear an approved wrist-strap grounding device.Do not touch the bus connector or connector pins.Do not touch circuit components inside the module.If available, use a static-safe work station.
Position the board (2) in the cabinet over the two threaded standoffs at the top two corners of the board.
Install the seven screws onto the remaining standoffs around the edges of the board.
Connect the wire connectors. Verify the labeling of each connector for proper placement. Refer to Illustration 2.
Set the date of installation for each flywheel bearing. The date can be set in the UPSView display. Note: Retrieve the following information from service records.
Devices > CS_HV 1 / 2 / (3 / 4)
Op. Params > Op. Group 5: > A / B Bearing Install Day
Op. Params > Op. Group 5: > A / B Bearing Install Month
Op. Params > Op. Group 5: > A / B Bearing Install Year
Calibrate the board (2). DC Bus Open
Refer to Systems Operation, Testing and Adjusting, RENR7654, "Flywheel Load Cell - Calibrate" and Systems Operation, Testing and Adjusting, RENR7654, "Flywheel DC Bus Current - Calibrate".
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts engine Caterpillar catalog:
1045294
ENGINE AR
3306C
3306C
2870096
ENGINE AR
320C
320C
3053140
ENGINE AR
CS-533E
CS-533E
4P6983
ENGINE AR
3412
3412
2901145
ENGINE AR
D6R II
D6R II
4W7315
ENGINE AR
3208
3208