3838415 ENGINE AR Caterpillar parts
140M
Rating:
Alternative (cross code) number:
CA3838415
383-8415
3838415
CA3838415
383-8415
3838415
MOTOR GRADER,
Compatible equipment models: 3838415:
Information:
Table 1
OPERATION    
Warning Category    Warning Indications (1)    "Operator Action Required"    "Possible Result " (2)    
"Alert Indicator Flashes " (3) "Action Lamp Flashes" (4)    "Action Alarm Sounds "    
1     X             No immediate action is required. The system needs attention soon.     No harmful effects or no damaging effects.    
2     X     X (4)         Change machine operation or perform maintenance to the system.     Severe damage to components can occur.    
2-S     X     X (4)     X (5)     Immediately change the machine operation.     Severe damage to machine components    
3     X     X (4)     X (6)     Immediately perform a safe engine shutdown.     Injury to the operator or severe damage to components can occur.    
( 1 ) The active warning indications are marked with an X.
( 2 ) This is the possible result if no action is taken by the operator.
( 3 ) The alert indicator flashes at a 8 Hz rate.
( 4 ) The action lamp flashes at a 1 Hz rate. This means that the action lamp is ON for one second and the action lamp is OFF for one second.
( 5 ) Steady
( 6 ) The action alarm sounds at a 1 Hz rate. This means that the action alarm is ON for one second and the action alarm is OFF for one second.
Illustration 1 g00302063
Gauge Cluster Module (1) Gauge warning area. (2) Pictograph symbol.
Illustration 2 g00515428
Message Center Module (7) Alert indicator. (8) Data logging indicator. (9) Message area. (10) Universal gauge (11) Gauge warning area The operator will be warned of immediate problems with a machine system or impending problems with a machine system by VIMS. Warning operations are activated when the VIMS electronic control module detects a problem with a signal. The "problem signal" reflects an abnormal condition of the machine (data events). Warning operations are also activated when the VIMS electronic control module detects a problem with the control system ("maintenance/diagnostic events"). Switches, sensors and other electronic control modules send electronic signals to the VIMS electronic control module. The "problem signals" are listed here:
When a condition exceeds the trip point of the switch, the switch opens.
When a condition exceeds the trip point of the switch, the switch closes.
Any abnormal sensor signal that is detected by the VIMS electronic control moduleThe VIMS electronic control module analyzes the "problem signals". The VIMS ECM then notifies the operator by activating the appropriate warning indications on the display components. The warning indications are listed here:
FLASHING of the alert indicator on the message center. ("The alert indicator flashes approximately ten times per second.")
The action lamp FLASHES. ("The action lamp ON one second and OFF one second.")
The action alarm is SOUNDED. ("The action alarm is turned ON for one second and turned OFF for one second for category 3 and the action alarm is turned on countinuously for category 2-S.")Note: More than one input is required
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts engine Caterpillar catalog:
3998215
ENGINE AR
140M, 140M 2, 160M, 160M 2
140M, 140M 2, 160M, 160M 2
3878498
ENGINE AR
140M
140M
3843465
ENGINE AR-CORE
140M, 160M
140M, 160M
3998217
ENGINE AR-CORE
140M, 140M 2, 160M, 160M 2
140M, 140M 2, 160M, 160M 2
3878499
ENGINE AR-CORE
12M, 140M
12M, 140M
3833540
ENGINE AR-CORE
12M 2
12M 2