Information:
Setpoint Viewing/Programming menu is entered by pressing the "MODE" button from the Fault Viewing/Clearing menu or the I/O Monitoring/Programming menu. The Setpoint Viewing/Programming menu allows the operator to view program PRCM setpoints. The Setpoint Viewing/Programming menu also allows the operator to program the PRCM setpoints.
Table 1
PRCM SETPOINTS    
Setpoint Number     Setpoint Value     Description    
P01     01     Genset or center marine engine.    
02 Port marine engine.    
03 Starboard marine engine.    
P02     01     All outputs controlled by the ECM remain in the state required by the last valid input, if communications from the ECM are lost (CAT data link failure).    
02 All outputs controlled from the ECM are reset to OFF.    
P03     01     PRCM displays CID 590 FMI 09 and CID 248 FMI 11 diagnostic codes when the diagnostic codes are active, but does NOT place the diagnostic codes in the PRCM fault log.    
02 PRCM displays CID 590 FMI 09 and CID 248 FMI 11 diagnostic codes when the codes are active and places the diagnostic codes in the fault log.    The upper display will be blank and the lower display will show "P01 0X". The "X" represents 1, 2, or 3. The 1, 2, and 3 represents the different types of engines.
Illustration 1 g00713203
In the following example, the setpoint "P01" is programmed to "02". A "02" is for the marine engine that is located on the port side.
The "UP" and "DOWN" buttons are used in order to scroll through the list of setpoints.
To program a setpoint, press the "ENTER" button. The password must be entered before the operator is allowed to enter the programming function. Refer to Systems Operation, "Input/Output Monitoring and Programming" for detailed instructions on entering the password. After you enter the password, the setpoint number should be flashing.
Use the "UP" and "DOWN" buttons to obtain the desired setpoint.
Illustration 2 g00713210
Press the "LEFT" and "RIGHT" button. The setpoint value is flashing.
Illustration 3 g00713215
Use the "UP" and "DOWN" buttons in order to change the value of the setpoints.
Illustration 4 g00713215
Press the "LEFT" and "RIGHT" button. All the characters flash.
Press the "LEFT" and "RIGHT" button in order to reject the changes. Press the "SELECT" button in order to accept the changes. The display will stop flashing for two seconds. When the display of the setpoint number begins to flash the operator is allowed to start programming the next setpoint.
After programming is complete, press "ENTER"in order to leave the programming mode and return to viewing the setpoints.
Table 1
PRCM SETPOINTS    
Setpoint Number     Setpoint Value     Description    
P01     01     Genset or center marine engine.    
02 Port marine engine.    
03 Starboard marine engine.    
P02     01     All outputs controlled by the ECM remain in the state required by the last valid input, if communications from the ECM are lost (CAT data link failure).    
02 All outputs controlled from the ECM are reset to OFF.    
P03     01     PRCM displays CID 590 FMI 09 and CID 248 FMI 11 diagnostic codes when the diagnostic codes are active, but does NOT place the diagnostic codes in the PRCM fault log.    
02 PRCM displays CID 590 FMI 09 and CID 248 FMI 11 diagnostic codes when the codes are active and places the diagnostic codes in the fault log.    The upper display will be blank and the lower display will show "P01 0X". The "X" represents 1, 2, or 3. The 1, 2, and 3 represents the different types of engines.
Illustration 1 g00713203
In the following example, the setpoint "P01" is programmed to "02". A "02" is for the marine engine that is located on the port side.
The "UP" and "DOWN" buttons are used in order to scroll through the list of setpoints.
To program a setpoint, press the "ENTER" button. The password must be entered before the operator is allowed to enter the programming function. Refer to Systems Operation, "Input/Output Monitoring and Programming" for detailed instructions on entering the password. After you enter the password, the setpoint number should be flashing.
Use the "UP" and "DOWN" buttons to obtain the desired setpoint.
Illustration 2 g00713210
Press the "LEFT" and "RIGHT" button. The setpoint value is flashing.
Illustration 3 g00713215
Use the "UP" and "DOWN" buttons in order to change the value of the setpoints.
Illustration 4 g00713215
Press the "LEFT" and "RIGHT" button. All the characters flash.
Press the "LEFT" and "RIGHT" button in order to reject the changes. Press the "SELECT" button in order to accept the changes. The display will stop flashing for two seconds. When the display of the setpoint number begins to flash the operator is allowed to start programming the next setpoint.
After programming is complete, press "ENTER"in order to leave the programming mode and return to viewing the setpoints.
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts engine Caterpillar catalog:
2524430
ENGINE AR-CORE
C9, CX31-C9I, TH31-E61
C9, CX31-C9I, TH31-E61
2612204
ENGINE AR-CORE
C9, CX31-C9I, TH31-E61
C9, CX31-C9I, TH31-E61
3426056
ENGINE AR-COMPLETE
C9, CX31-C9I, TH31-E61
C9, CX31-C9I, TH31-E61
1W3884
ENGINE AR
3304, 3412
3304, 3412
9Y7549
ENGINE AR
3406B
3406B