Check the exciter armature. Ensure that the rotating rectifier is tight. If a failure of a rectifier is suspected, proceed to the "Testing a Three-Diode Rectifier Block" section.Testing a Three-Diode Rectifier Block
Illustration 1 g00610240
Illustration 2 g00613971
Three-Diode Rectifier Block (two pieces)
The following procedure tests all three diodes within a block. Check the positive rectifier block and the negative rectifier block. If any meter reading does not fall within the given ranges, replace the rectifier block.
Set the digital multimeter on the diode range. Remove all leads from the rectifier block.
To test the negative rectifier block, follow these steps:
Place the red test lead on the negative "-" terminal. Place the black test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). All readings on the meter should be between 0.4 and 1.0.
Place the black test lead on the negative "-" terminal. Place the red test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). In all cases, the meter should read "OL" (overload).
To test the positive rectifier block, follow these steps:
Place the red test lead on the positive "+" rectifier terminal. Place the black test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). In all cases, the meter should read "OL" (overload).
Place the black test lead on the positive "+" rectifier terminal. Place the red test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). All readings on the meter should be between 0.4 and 1.0. Note: A shorted diode can damage the exciter rotor. If a diode is shorted, check the exciter rotor. Refer to the Testing and Adjusting, "Winding - Test" and Testing and Adjusting, "Insulation - Test". Perform these tests.Note: This rectifier block also contains varistor "CR7". "CR7" can be checked by measuring the resistance between the positive "+" rectifier terminal and the negative "-" rectifier terminal. The resistance should be a minimum of 15000 ohms.
Illustration 1 g00610240
Illustration 2 g00613971
Three-Diode Rectifier Block (two pieces)
The following procedure tests all three diodes within a block. Check the positive rectifier block and the negative rectifier block. If any meter reading does not fall within the given ranges, replace the rectifier block.
Set the digital multimeter on the diode range. Remove all leads from the rectifier block.
To test the negative rectifier block, follow these steps:
Place the red test lead on the negative "-" terminal. Place the black test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). All readings on the meter should be between 0.4 and 1.0.
Place the black test lead on the negative "-" terminal. Place the red test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). In all cases, the meter should read "OL" (overload).
To test the positive rectifier block, follow these steps:
Place the red test lead on the positive "+" rectifier terminal. Place the black test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). In all cases, the meter should read "OL" (overload).
Place the black test lead on the positive "+" rectifier terminal. Place the red test lead on the following rectifier terminals: "AC1" (3), "AC2" (4) and "AC3" (5). All readings on the meter should be between 0.4 and 1.0. Note: A shorted diode can damage the exciter rotor. If a diode is shorted, check the exciter rotor. Refer to the Testing and Adjusting, "Winding - Test" and Testing and Adjusting, "Insulation - Test". Perform these tests.Note: This rectifier block also contains varistor "CR7". "CR7" can be checked by measuring the resistance between the positive "+" rectifier terminal and the negative "-" rectifier terminal. The resistance should be a minimum of 15000 ohms.
Cat SIS web machinery list:
Parts ether Caterpillar catalog:
5G0595
ETHER STARTING AID GROUP
931, D3
931, D3
6N7672
ETHER ATOMIZER SPRAY
215, 245, 245B, 24H, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3456, 5110B, 527, 583R, 587R, 589, 615, 615C, 621, 621B, 621E, 621F, 623E, 623F, 627E, 627F, 637D, 651E, 657E, 725, 730, 735, ...
215, 245, 245B, 24H, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3456, 5110B, 527, 583R, 587R, 589, 615, 615C, 621, 621B, 621E, 621F, 623E, 623F, 627E, 627F, 637D, 651E, 657E, 725, 730, 735, ...
1308414
ETHER CYLINDER
416F, 420F, 428F, 430F, 432F, 434F, 444F, 450F, 933, 933C, 939, 939C, D3C III, D3G, D4C III, D4G, D5C III, D5G
416F, 420F, 428F, 430F, 432F, 434F, 444F, 450F, 933, 933C, 939, 939C, D3C III, D3G, D4C III, D4G, D5C III, D5G
4Y2906
ETHER STARTING AID
E300, E300B
E300, E300B
2366667
ETHER AID WIRING GROUP
950H, 962H
950H, 962H
9G8211
ETHER CYLINDER
336E, 336E H, 336E HVG, 336E L, 336E LH, 336E LN, 336F L, 572G, 916, 918F, 926, 936, 936F, 938F, 938G, 950B, 950F, 950H, 953, 963, 966D, 966F, 966G, 966G II, 966H, 970F, 973, 980C, 980F, 980G, 980G II...
336E, 336E H, 336E HVG, 336E L, 336E LH, 336E LN, 336F L, 572G, 916, 918F, 926, 936, 936F, 938F, 938G, 950B, 950F, 950H, 953, 963, 966D, 966F, 966G, 966G II, 966H, 970F, 973, 980C, 980F, 980G, 980G II...
6N7672
ETHER ATOMIZER SPRAY
215, 245, 245B, 24H, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3456, 5110B, 527, 583R, 587R, 589, 615, 615C, 621, 621B, 621E, 621F, 623E, 623F, 627E, 627F, 637D, 651E, 657E, 725, 730, 735, ...
215, 245, 245B, 24H, 3406, 3406B, 3406C, 3406E, 3408, 3408C, 3412, 3412C, 3456, 5110B, 527, 583R, 587R, 589, 615, 615C, 621, 621B, 621E, 621F, 623E, 623F, 627E, 627F, 637D, 651E, 657E, 725, 730, 735, ...