2539814 EXCITER GP Caterpillar parts
3512, 3512B, 3512C, C27, C32
Rating:
Alternative (cross code) number:
CA2539814
253-9814
2539814
CA2539814
253-9814
2539814
GENERATOR SET,
Information:
Automatic Operation
The power module can be used in parallel with other units to provide power for an isolated load. Automatic operation refers to the use of the on-board control system to close the generator breaker automatically. The following information describes the steps for automatic operation.
Ensure that all load cable connections have been correctly made.
Verify that the unit can be safely started.
Verify that power can be applied to the load. Pre-startup Procedures
Install wiring from the remote run request contact. Note: The remote run request contact is controlled by the automatic transfer switch or by other customer supplied controls.
Press the EMCP 4.4 "AUTO" key in each unit so that all units are in "AUTO" mode. Note: The sync mode setting in the EMCP 4.4 will automatically change to "AUTO" whenever the EMCP 4.4 is put in "AUTO" modeNote: For automatic breaker close control, the generator breaker control switch must be in the normal position (not in trip).Startup Procedure
All units can be started simultaneously using a remote run request contact.
After the lead unit is running at rated speed, then the generator breaker will close automatically to a dead bus.
All of the other units will automatically synchronize and then close to the live bus. Note: Alternatively, each unit can be started individually, beginning with the lead unit, first placing the EMCP 4.4 sync mode switch in "auto" mode. After placing the EMCP 4.4 sync mode switch in "auto" mode, press the "RUN" button on the EMCP 4.4. The generator breaker will close automatically once the unit is up to rated voltage and frequency and synchronized with the bus.The paralleled units now power the load and share the load proportionally.Shutdown Procedure
Any of the methods below will initiate a normal shutdown:
If a remote run request contact is used to start the units, then open the contact in order to put all units in stop/cooldown.
Press the "STOP" button that is on the EMCP 4.4 in each unit to put all units in stop/cooldown. Note: First, verify load level permits unit shutdown without over-burdening the remaining paralleled units.Note: Pressing "STOP" begins ramping down generator output. At the programmed kW trip level, the breaker will automatically trip open and engine will go into cooldown.Generator Circuit Breaker
The generator circuit breaker is a 100% rated universal power circuit breaker. The generator circuit breaker is designed to protect electrical systems from damage caused by overloads, short circuits, and equipment ground faults. The circuit breaker is designed to open and close a circuit electrically. The circuit breaker is designed to open the circuit automatically at a predetermined over current setting.The generator circuit breaker is operated via a stored energy mechanism. The stored energy mechanism can be charged manually or charged by using a motor. The closing time is less than five cycles. Closing and opening operations can be initiated by electrical signals.Closing the Breaker
The generator circuit breaker can be closed automatically when running in the "AUTO" mode or manually with the circuit breaker switch in the "RUN" mode. All of the
The power module can be used in parallel with other units to provide power for an isolated load. Automatic operation refers to the use of the on-board control system to close the generator breaker automatically. The following information describes the steps for automatic operation.
Ensure that all load cable connections have been correctly made.
Verify that the unit can be safely started.
Verify that power can be applied to the load. Pre-startup Procedures
Install wiring from the remote run request contact. Note: The remote run request contact is controlled by the automatic transfer switch or by other customer supplied controls.
Press the EMCP 4.4 "AUTO" key in each unit so that all units are in "AUTO" mode. Note: The sync mode setting in the EMCP 4.4 will automatically change to "AUTO" whenever the EMCP 4.4 is put in "AUTO" modeNote: For automatic breaker close control, the generator breaker control switch must be in the normal position (not in trip).Startup Procedure
All units can be started simultaneously using a remote run request contact.
After the lead unit is running at rated speed, then the generator breaker will close automatically to a dead bus.
All of the other units will automatically synchronize and then close to the live bus. Note: Alternatively, each unit can be started individually, beginning with the lead unit, first placing the EMCP 4.4 sync mode switch in "auto" mode. After placing the EMCP 4.4 sync mode switch in "auto" mode, press the "RUN" button on the EMCP 4.4. The generator breaker will close automatically once the unit is up to rated voltage and frequency and synchronized with the bus.The paralleled units now power the load and share the load proportionally.Shutdown Procedure
Any of the methods below will initiate a normal shutdown:
If a remote run request contact is used to start the units, then open the contact in order to put all units in stop/cooldown.
Press the "STOP" button that is on the EMCP 4.4 in each unit to put all units in stop/cooldown. Note: First, verify load level permits unit shutdown without over-burdening the remaining paralleled units.Note: Pressing "STOP" begins ramping down generator output. At the programmed kW trip level, the breaker will automatically trip open and engine will go into cooldown.Generator Circuit Breaker
The generator circuit breaker is a 100% rated universal power circuit breaker. The generator circuit breaker is designed to protect electrical systems from damage caused by overloads, short circuits, and equipment ground faults. The circuit breaker is designed to open and close a circuit electrically. The circuit breaker is designed to open the circuit automatically at a predetermined over current setting.The generator circuit breaker is operated via a stored energy mechanism. The stored energy mechanism can be charged manually or charged by using a motor. The closing time is less than five cycles. Closing and opening operations can be initiated by electrical signals.Closing the Breaker
The generator circuit breaker can be closed automatically when running in the "AUTO" mode or manually with the circuit breaker switch in the "RUN" mode. All of the
Caterpillar SIS machinery equipment:
Caterpillar SIS
G3512 Generator Set E2P00001-UP »
253-9814
EXCITER GP
G3512 Generator Set E2T00001-UP »
253-9814
EXCITER GP
C32 Generator Set FLX00001-UP »
253-9814
EXCITER GP
C27 Generator Set 2A300001-UP »
253-9814
EXCITER GP
C27 Generator Set 2A300001-UP »
253-9814
EXCITER GP
3516 Generator Set LNN00001-UP »
253-9814
EXCITER GP
3516B Generator Set LNW00001-UP »
253-9814
EXCITER GP
3516B Generator Set LNZ00001-UP »
253-9814
EXCITER GP
3512 Generator Set LNF00001-UP »
253-9814
EXCITER GP
3512B Generator Set LNJ00001-UP »
253-9814
EXCITER GP
3512B Generator Set LNM00001-UP »
253-9814
EXCITER GP
3512B Generator Set LY800001-UP »
253-9814
EXCITER GP
3512 Generator Set LY700001-UP »
253-9814
EXCITER GP
C32 Marine Generator Set GM200001-UP »
253-9814
EXCITER GP
C32 Marine Generator Set GM300001-UP »
253-9814
EXCITER GP
C32 Marine Generator Set MG400001-UP »
253-9814
EXCITER GP
3512C Generator Set LYH00001-UP »
253-9814
EXCITER GP
C32 Generator Set JTW00001-UP »
253-9814
EXCITER GP
C32 Generator Set JTW00001-UP »
253-9814
EXCITER GP
G3516B Generator Set E6T00001-UP »
253-9814
EXCITER GP
C32 Generator Set PAE00001-UP »
253-9814
EXCITER GP
G3512 Natural Gas Generator Set E2600001-UP »
253-9814
EXCITER GP
G3512 Natural Gas Generator Set E2700001-UP »
253-9814
EXCITER GP
C32 Generator Set P7E00001-UP »
253-9814
EXCITER GP
C32 Generator Set for LRC NRC00001-UP »
253-9814
EXCITER GP
C32 Generator Set for LRC NRC00001-UP »
253-9814
EXCITER GP
3512 Generator Set ZAF00001-UP »
253-9814
EXCITER GP
3512B Generator Set ZAH00001-UP »
253-9814
EXCITER GP
3512C Generator Set SBG00001-UP »
253-9814
EXCITER GP
C32 Generator SET JSJ00001-UP »
253-9814
EXCITER GP
3512 Generator Set YAK00001-UP »
253-9814
EXCITER GP
3512B Generator Set YAM00001-UP »
253-9814
EXCITER GP
3512B Generator Set YAN00001-UP »
253-9814
EXCITER GP
3512 Generator Set YAX00001-UP »
253-9814
EXCITER GP
3512B Generator Set YAY00001-UP »
253-9814
EXCITER GP
C27 Generator Set T4Z00001-UP »
253-9814
EXCITER GP
C32 Marine Generator SET RNF00001-UP »
253-9814
EXCITER GP
C32 Marine Generator Set DSJ00001-UP »
253-9814
EXCITER GP
C27 Generator Set GDS00001-UP »
253-9814
EXCITER GP
C32 Generator Set JAZ00001-UP »
253-9814
EXCITER GP
C32 Generator Set JAZ00001-UP »
253-9814
EXCITER GP
C32 Marine Generator Set RTK00001-UP »
253-9814
EXCITER GP
3512 Generator Set YBA00001-UP »
253-9814
EXCITER GP
3512 Generator Set YBA00001-UP »
253-9814
EXCITER GP
3512B Generator Set YBB00001-UP »
253-9814
EXCITER GP
3512B Generator Set YBB00001-UP »
253-9814
EXCITER GP
3512C Generator Set YBD00001-UP »
253-9814
EXCITER GP
3512C Generator Set YBD00001-UP »
253-9814
EXCITER GP
G3516 Generator Set E6R00001-UP »
253-9814
EXCITER GP
G3516 Gas Generator Set E6W00001-UP »
253-9814
EXCITER GP
3512 Generator Set JM200001-UP »
253-9814
EXCITER GP
3512 Generator Set JM200001-UP »
253-9814
EXCITER GP
3512B Generator Set JM300001-UP »
253-9814
EXCITER GP
3512B Generator Set JM300001-UP »
253-9814
EXCITER GP
3512B Generator Set JM400001-UP »
253-9814
EXCITER GP
Cat SIS web machinery list:
Parts exciter Caterpillar catalog:
2689737
EXCITER GP
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C32, G3512, PM3516, PMG3516
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C32, G3512, PM3516, PMG3516
2533516
EXCITER GP
3512B, 3512C, 3516, 3516B, 3516C, C175-16, C175-20, G3516H, XQC1600
3512B, 3512C, 3516, 3516B, 3516C, C175-16, C175-20, G3516H, XQC1600
2787665
EXCITER GP
3512, 3512B, 3512C, 3516, 3516B, 3516C, C32
3512, 3512B, 3512C, 3516, 3516B, 3516C, C32
2533521
EXCITER GP
3512B, 3512C, 3516, 3516B, 3516C, C175-16, C175-20, G3516H, XQC1600
3512B, 3512C, 3516, 3516B, 3516C, C175-16, C175-20, G3516H, XQC1600
2747448
EXCITER GP
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C32, G3512E, G3516, G3516B, G3520C, G3520E
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C32, G3512E, G3516, G3516B, G3520C, G3520E
2796765
EXCITER GP
3512, 3512B, 3512C, C27, C32
3512, 3512B, 3512C, C27, C32
3865152
EXCITER GP
3512, 3512B, 3512C, C32
3512, 3512B, 3512C, C32
2747447
EXCITER GP
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C32, G3512E, G3516, G3516B, G3520C, G3520E
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C32, G3512E, G3516, G3516B, G3520C, G3520E
3396494
EXCITER GP
3512, 3512B, C32
3512, 3512B, C32
2689735
EXCITER GP
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C32, G3512, PM3516, PMG3516
3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C32, G3512, PM3516, PMG3516
2539799
EXCITER GP
3512, 3512B, 3512C, C27, C32
3512, 3512B, 3512C, C27, C32
2787682
EXCITER GP
3512, 3512B, 3512C, 3516, 3516B, 3516C, C32, G3512E
3512, 3512B, 3512C, 3516, 3516B, 3516C, C32, G3512E
3N4789
EXCITER AND REGULATOR ASSEMBLY
D346, D348
D346, D348
5L7041
EXCITER & REG AS
D320A
D320A
7L4208
EXCITER AND REGULATOR ASSEMBLY
3304, 3306
3304, 3306
2796765
EXCITER GP
3512, 3512B, 3512C, C27, C32
3512, 3512B, 3512C, C27, C32
1653815
EXCITER GP
3508, 3508C, 3512, 3512B, 3512C, 3516, 3516B, G3516, G3520C, G3520E, SR4B
3508, 3508C, 3512, 3512B, 3512C, 3516, 3516B, G3516, G3520C, G3520E, SR4B
5N9421
EXCITER & HEAT SINK AS
3406B, 3408, 3412, 3508, 3512, 3516, D379B, D398B, D399, G3508, G3512, G3516, G379, G398, G399, SR4
3406B, 3408, 3412, 3508, 3512, 3516, D379B, D398B, D399, G3508, G3512, G3516, G379, G398, G399, SR4
2152402
EXCITER GP
3306B, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, C18, C27, C32, G3508, G3512, G3512E, G3516, G3516B, G3516C, G3516E, G3520B, G3520C, G3520E, PM3508, PM3512, PM3516, PMG3516, PP3516, SR...
3306B, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C15, C18, C27, C32, G3508, G3512, G3512E, G3516, G3516B, G3516C, G3516E, G3520B, G3520C, G3520E, PM3508, PM3512, PM3516, PMG3516, PP3516, SR...
3865152
EXCITER GP
3512, 3512B, 3512C, C32
3512, 3512B, 3512C, C32
1N9062
EXCITER AND REGULATOR ASSEMBLY
D342, D342C, D353C, G342C, G353D
D342, D342C, D353C, G342C, G353D
1424453
EXCITER GP
3306B, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C27, C32, G3508, G3512E, G3516, G3516B, G3516C, G3516E, G3520B, G3520C, G3520E, PM3508, PM3512, PM3516, PMG3516, PP3516, SR4B
3306B, 3508, 3508B, 3512, 3512B, 3512C, 3516, 3516B, 3516C, C27, C32, G3508, G3512E, G3516, G3516B, G3516C, G3516E, G3520B, G3520C, G3520E, PM3508, PM3512, PM3516, PMG3516, PP3516, SR4B
1N5500
EXCITER AND REGULATOR ASSEMBLY
D346, D348, D379, D398, G379, G398, G399
D346, D348, D379, D398, G379, G398, G399
2503831
EXCITER GP
3512B, 3512C, 3516, 3516B, G3512E, G3516B, G3516C, G3516E, SR4B
3512B, 3512C, 3516, 3516B, G3512E, G3516B, G3516C, G3516E, SR4B