1P7405 EYEBOLT Caterpillar parts
3606, 3608, 3612, 3616, 583R, 583T, 587R, 587T, 589, 943, 953, D10R, D10T, D10T2, D11N, D11R, D11T, D7H, D8N, D8R, D8R II, D8T, D9R, D9T, G3606, G3608, G3612, G3616, PL83, PL87, R2900G
Rating:
Alternative (cross code) number:
CA1P7405
1P-7405
1P7405
CA1P7405
1P-7405
1P7405
Weight: 0.14 pounds 0 kg.
Information:
LENGTH TO EYE CENTERLINE
54.735
mm
RING ID
25.4
mm
RING OD
42.93
mm
SHOULDER DIAMETER
0
mm
THREAD LENGTH
22.35
WIDTH
0
THREAD SIZE
.38-16
GAS ENGINE, TRACK-TYPE TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
CTP 1P7405 Grade 8 Lifting Head Plain Eyebolt, 3/8"-16 UNC Thread Size
CTP Lifting Type of Head || Plain Coated || 3/8"-16 UNC Thread Size
CTP Lifting Type of Head || Plain Coated || 3/8"-16 UNC Thread Size
CTP 1P7405 Grade 8 Lifting Head Plain Eyebolt, 3/8"-16 UNC Thread Size
CTP Lifting Type of Head || Plain Coated || 3/8"-16 UNC Thread Size
CTP Lifting Type of Head || Plain Coated || 3/8"-16 UNC Thread Size
Compatible equipment models: 1P7405:
Information:
Recommended Periodic Insulation Tests
The high voltage that is produced by an operating generator set can cause severe injury or death. Before performing any maintenance or repairs, ensure that the generator will not start.Place the engine control switch in the "OFF" position. Attach "DO NOT OPERATE" tags to all starting controls. Disconnect the batteries or disable the starting system. Lock out all switchgear and automatic transfer switches that are associated with the generator.
Table 1
Tools Needed
Part Number Part Name Quantity
300-8648 Insulation Testing Gp 1 Periodically, use an insulation tester to check the insulation resistance of the generator's main stator winding. The frequency of this test is determined by the generator's environment. Previous insulation tester readings will also determine the frequency of this test.Test the main stator windings with an insulation tester in the following situations:
The generator set is started for the first time.
The generator set is removed from storage.
The generator set is operating in a humid environment. Test every three months.
The generator set is not protected from the elements in an enclosed area. Test every three months.
The generator set is installed in an enclosed area. This area needs to be low in humidity and this area needs to have steady temperatures. Test every twelve months (minimum).
The generator set has not been run under load for three months. Test the generator set weekly. Use space heaters around the generator set if the generator is exposed to a sea water environment or if the humidity is above 75 percent. Also use space heaters if a test result was below 3 megohms.Space heaters must be used whenever the generator set is not under load. Space heaters must also be used whenever salt is present or whenever high humidity is present. Using a space heater in this fashion is the only way to maintain insulation tester readings above one megohm. Use space heaters only when the generator is not running.For additional information, refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".Recommended Procedure for the Insulation Test
Personal injury or death can result from electrocution.The megohmmeter is applying a high voltage to the circuit.To avoid electrocution, do not touch the instrument leads without first discharging them. When finished testing also discharge the generator windings.
Take the generator out of service.
Visually inspect the generator for moisture. If moisture exists, do not perform this insulation test. Dry the unit first. Refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".
Inspect the installation. Determine the equipment that will be tested by the insulation tester.
Discharge the capacitance of the windings.
Disconnect "T0" from ground.
Disconnect the sensing lead wires for the regulator. This may be accomplished by unplugging the harness connectors.
Disconnect the PT leads of the load share module.
Connect the insulation tester's Black lead to ground.
Connect the insulation tester's RED lead to "T0".
Set the voltage to the rated voltage of the generator.
Use the 30/60 Time Resistance Method:
Apply voltage.
Observe the readings at 30 seconds. Observe the readings at 60 seconds.
Record the 60 second reading. This reading must be
The high voltage that is produced by an operating generator set can cause severe injury or death. Before performing any maintenance or repairs, ensure that the generator will not start.Place the engine control switch in the "OFF" position. Attach "DO NOT OPERATE" tags to all starting controls. Disconnect the batteries or disable the starting system. Lock out all switchgear and automatic transfer switches that are associated with the generator.
Table 1
Tools Needed
Part Number Part Name Quantity
300-8648 Insulation Testing Gp 1 Periodically, use an insulation tester to check the insulation resistance of the generator's main stator winding. The frequency of this test is determined by the generator's environment. Previous insulation tester readings will also determine the frequency of this test.Test the main stator windings with an insulation tester in the following situations:
The generator set is started for the first time.
The generator set is removed from storage.
The generator set is operating in a humid environment. Test every three months.
The generator set is not protected from the elements in an enclosed area. Test every three months.
The generator set is installed in an enclosed area. This area needs to be low in humidity and this area needs to have steady temperatures. Test every twelve months (minimum).
The generator set has not been run under load for three months. Test the generator set weekly. Use space heaters around the generator set if the generator is exposed to a sea water environment or if the humidity is above 75 percent. Also use space heaters if a test result was below 3 megohms.Space heaters must be used whenever the generator set is not under load. Space heaters must also be used whenever salt is present or whenever high humidity is present. Using a space heater in this fashion is the only way to maintain insulation tester readings above one megohm. Use space heaters only when the generator is not running.For additional information, refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".Recommended Procedure for the Insulation Test
Personal injury or death can result from electrocution.The megohmmeter is applying a high voltage to the circuit.To avoid electrocution, do not touch the instrument leads without first discharging them. When finished testing also discharge the generator windings.
Take the generator out of service.
Visually inspect the generator for moisture. If moisture exists, do not perform this insulation test. Dry the unit first. Refer to Special Instruction, SEHS9124, "Cleaning and Drying of Electric Set Generators".
Inspect the installation. Determine the equipment that will be tested by the insulation tester.
Discharge the capacitance of the windings.
Disconnect "T0" from ground.
Disconnect the sensing lead wires for the regulator. This may be accomplished by unplugging the harness connectors.
Disconnect the PT leads of the load share module.
Connect the insulation tester's Black lead to ground.
Connect the insulation tester's RED lead to "T0".
Set the voltage to the rated voltage of the generator.
Use the 30/60 Time Resistance Method:
Apply voltage.
Observe the readings at 30 seconds. Observe the readings at 60 seconds.
Record the 60 second reading. This reading must be
Cat SIS web machinery list:
Parts eyebolt Caterpillar catalog:
1P7409
EYEBOLT
130G, 3606, 3608, 3612, 3616, G3606, G3608, G3612, G3616, PM-201, PM-565, PM-565B
130G, 3606, 3608, 3612, 3616, G3606, G3608, G3612, G3616, PM-201, PM-565, PM-565B
1P7407
EYEBOLT
325B L, 330B L, 330C L, 345B II, 345B L, 3606, 3608, 3612, 3616, 910, 916, 926, 930R, 931B, 931C II, 933, 939, D3C II, D3C III, D4C III, D5C III, G3606, G3608, G3612, G3616, IT28, IT28B, R1300, R1300G...
325B L, 330B L, 330C L, 345B II, 345B L, 3606, 3608, 3612, 3616, 910, 916, 926, 930R, 931B, 931C II, 933, 939, D3C II, D3C III, D4C III, D5C III, G3606, G3608, G3612, G3616, IT28, IT28B, R1300, R1300G...
1P7404
EYEBOLT
3406C, 3412, 3508, 3512, 3516, 3516B, 814F, 815F, 816F, 824G, 824G II, 825G, 825G II, 826G, 826G II, 834G, 836G, 844, 844H, 844K, 854G, 854K, 936F, 950F, 950F II, 960F, 966F, 966F II, 970F, 980F, 980F...
3406C, 3412, 3508, 3512, 3516, 3516B, 814F, 815F, 816F, 824G, 824G II, 825G, 825G II, 826G, 826G II, 834G, 836G, 844, 844H, 844K, 854G, 854K, 936F, 950F, 950F II, 960F, 966F, 966F II, 970F, 980F, 980F...
4C8358
EYEBOLT
5130, 5130B, 5230, 844K, 854K, 990K, 992K, 993K, D10T2, D11T
5130, 5130B, 5230, 844K, 854K, 990K, 992K, 993K, D10T2, D11T
2D1201
EYEBOLT
3406B, 980B, AD40, AD45, AE40, AE40 II
3406B, 980B, AD40, AD45, AE40, AE40 II
3T3396
EYEBOLT
3116, 3126, 3126B, 3208, C7
3116, 3126, 3126B, 3208, C7
8N5001
EYEBOLT
3116, 3208, 844, 844H, 854G, 854K, 990 II, 990H, 992G, 992K, 994F
3116, 3208, 844, 844H, 854G, 854K, 990 II, 990H, 992G, 992K, 994F
5L7820
EYEBOLT
3208, 3306, 3406, 3406B, 3408, D333A, D333B, D334, D342, D342C, D343
3208, 3306, 3406, 3406B, 3408, D333A, D333B, D334, D342, D342C, D343
3879865
EYEBOLT
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP, 306E, 307E, 308E, 308E CR, 308E SR, 308E2 CR, 906H2, 907H2, 908H2, 910K, 914K
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP, 306E, 307E, 308E, 308E CR, 308E SR, 308E2 CR, 906H2, 907H2, 908H2, 910K, 914K
2129421
EYEBOLT AS
TL4 24
TL4 24
2Y5321
EYEBOLT
3304, 3304B, 3306, 3306B
3304, 3304B, 3306, 3306B
4F4403
EYEBOLT
44, D379B, G399
44, D379B, G399
3L9168
EYEBOLT
3181, 3192, 7211, 7231, 7241, 7251, 7261
3181, 3192, 7211, 7231, 7241, 7251, 7261
4C8359
EYEBOLT
3512C, 3516C, 924H, 928H, C175-16, IT28G
3512C, 3516C, 924H, 928H, C175-16, IT28G
3E3879
EYEBOLT
320C FM, 3406C, 3406E, 3412C, 3456, 345C, 3508, 3508B, 3512, 3512B, 3516, 3516B, 5130, 5130B, 5230, 5230B, C18
320C FM, 3406C, 3406E, 3412C, 3456, 345C, 3508, 3508B, 3512, 3512B, 3516, 3516B, 5130, 5130B, 5230, 5230B, C18
1P7407
EYEBOLT
325B L, 330B L, 330C L, 345B II, 345B L, 3606, 3608, 3612, 3616, 910, 916, 926, 930R, 931B, 931C II, 933, 939, D3C II, D3C III, D4C III, D5C III, G3606, G3608, G3612, G3616, IT28, IT28B, R1300, R1300G...
325B L, 330B L, 330C L, 345B II, 345B L, 3606, 3608, 3612, 3616, 910, 916, 926, 930R, 931B, 931C II, 933, 939, D3C II, D3C III, D4C III, D5C III, G3606, G3608, G3612, G3616, IT28, IT28B, R1300, R1300G...