2D1201 EYEBOLT Caterpillar parts
3406B, 980B, AD40, AD45, AE40, AE40 II
Rating:
Alternative (cross code) number:
CA2D1201
2D-1201
2D1201
CA2D1201
2D-1201
2D1201
Weight: 0.60 pounds 0 kg.
Information:
LENGTH TO EYE CENTERLINE
78.615
mm
RING ID
34.8
mm
RING OD
64.77
mm
SHOULDER DIAMETER
0
mm
THREAD LENGTH
35.05
WIDTH
0
THREAD SIZE
.62-11
MARINE ENGINE, WHEEL LOADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
25 Jun 2018
75 Hundredths Pounds
Regal: Regal
Replaces Caterpillar 2D1201 Lifting Eye Bolt 5/8" 2940lbs
Warranty
Warranty
Compatible equipment models: 2D1201:
Information:
PC to UPS/SMS or MMU Graphics Master Connection
The PC to UPS/SMS or MMU Graphics Master connection is used to monitor the messages and telemetry for the overall UPS/SMS or MMU, including the Flywheel Cabinets, and retrieve log files from both the UPS/SMS, MMU and the Flywheel Cabinets. The PC to UPS/SMS or MMU Graphics Master connection is also the main port where firmware is installed to the whole UPS/SMS or MMU (paralleled systems).The firmware updates for the UPS/SMS or MMU and Flywheel Cabinets are done from this location.
Illustration 1 g01292662
(1) Serial Port Location (Customer Connections Tray)
Illustration 2 g01292671
RS-232 Laptop interface for GM Access (2) Port A (RS232)The Graphics Master connection is located in the Customer Connections Tray located on the top of the Controls cabinet.The following instructions explain how to connect a PC serially to your UPS/SMS or MMU Graphics Master.
Open the cover to the Customer Connections Tray.
Connect a PC via a serial cable to the RS-232 Port that is indicated in Illustration 2.Note: The serial cable is a straight through DB9 male to DB9 female.
Turn on the PC.
Run the UPSView software.
Select "PC Settings" in the Menu Bar.
Illustration 3 g01292722
"Connection Settings"
Click Settings in the "PC Settings" menu. The UPSView "Connection Settings" window will open.
Ensure the "Direct Connect (serial)" radio button is selected.
Select the "Serial/Modem Port Number" that is appropriate for the PC.
Select the "Serial/Modem Baud Rate" that is desired.The default is 38400.
Ensure that the "Detailed (MMU) Telemetry" radio button is selected.
Select "Connect".The PC is now connected to the UPS/SMS or MMU. Text and telemetry are displayed via UPS View.Note: If text and telemetry are not displayed, check the "Serial/Modem Port Number" and the "Direct Connect (serial)" radio button for the proper settings. Additionally, check the cable length and type of serial cable used.
Select "Log On" in the Menu Bar when connection is established. The "Enter User Name / Password" window opens.
Enter a "User Name".
Enter a "Password".
Select "OK".After the "User Name" and "Password" have been accepted by the UPS/SMS or MMU, the Menu Bar includes "Op. Params", "Commands", "Calibrate", and "Log Off".Note: Before proceeding, wait for the new menu items to appear.PC To Service Port In The Controls Cabinet
The PC to Service Port in the Controls cabinet connection is used to monitor telemetry and messages from just the UPS/SMS or MMU, as well as retrieve log files from both the UPS/SMS or MMU. The PC to Service Port in the Controls cabinet connection does not access the information in the Flywheel Cabinets.
Illustration 4 g01292729
(5) Dual Network Interface Board
Illustration 5 g01292742
(6) UPSNet Dual Network Interface BoardThe Service Port is located on Dual Network Interface board.Note: If there are two Dual Network Interface boards that are installed on the machine, the Service Port is located on
The PC to UPS/SMS or MMU Graphics Master connection is used to monitor the messages and telemetry for the overall UPS/SMS or MMU, including the Flywheel Cabinets, and retrieve log files from both the UPS/SMS, MMU and the Flywheel Cabinets. The PC to UPS/SMS or MMU Graphics Master connection is also the main port where firmware is installed to the whole UPS/SMS or MMU (paralleled systems).The firmware updates for the UPS/SMS or MMU and Flywheel Cabinets are done from this location.
Illustration 1 g01292662
(1) Serial Port Location (Customer Connections Tray)
Illustration 2 g01292671
RS-232 Laptop interface for GM Access (2) Port A (RS232)The Graphics Master connection is located in the Customer Connections Tray located on the top of the Controls cabinet.The following instructions explain how to connect a PC serially to your UPS/SMS or MMU Graphics Master.
Open the cover to the Customer Connections Tray.
Connect a PC via a serial cable to the RS-232 Port that is indicated in Illustration 2.Note: The serial cable is a straight through DB9 male to DB9 female.
Turn on the PC.
Run the UPSView software.
Select "PC Settings" in the Menu Bar.
Illustration 3 g01292722
"Connection Settings"
Click Settings in the "PC Settings" menu. The UPSView "Connection Settings" window will open.
Ensure the "Direct Connect (serial)" radio button is selected.
Select the "Serial/Modem Port Number" that is appropriate for the PC.
Select the "Serial/Modem Baud Rate" that is desired.The default is 38400.
Ensure that the "Detailed (MMU) Telemetry" radio button is selected.
Select "Connect".The PC is now connected to the UPS/SMS or MMU. Text and telemetry are displayed via UPS View.Note: If text and telemetry are not displayed, check the "Serial/Modem Port Number" and the "Direct Connect (serial)" radio button for the proper settings. Additionally, check the cable length and type of serial cable used.
Select "Log On" in the Menu Bar when connection is established. The "Enter User Name / Password" window opens.
Enter a "User Name".
Enter a "Password".
Select "OK".After the "User Name" and "Password" have been accepted by the UPS/SMS or MMU, the Menu Bar includes "Op. Params", "Commands", "Calibrate", and "Log Off".Note: Before proceeding, wait for the new menu items to appear.PC To Service Port In The Controls Cabinet
The PC to Service Port in the Controls cabinet connection is used to monitor telemetry and messages from just the UPS/SMS or MMU, as well as retrieve log files from both the UPS/SMS or MMU. The PC to Service Port in the Controls cabinet connection does not access the information in the Flywheel Cabinets.
Illustration 4 g01292729
(5) Dual Network Interface Board
Illustration 5 g01292742
(6) UPSNet Dual Network Interface BoardThe Service Port is located on Dual Network Interface board.Note: If there are two Dual Network Interface boards that are installed on the machine, the Service Port is located on
Caterpillar parts catalog:
Parts eyebolt Caterpillar catalog:
5L7820
EYEBOLT
3208, 3306, 3406, 3406B, 3408, D333A, D333B, D334, D342, D342C, D343
3208, 3306, 3406, 3406B, 3408, D333A, D333B, D334, D342, D342C, D343
8S0933
EYEBOLT
120G, 12G, 130G, 140B, 140G, 14G, 160G, 16G, 215, 325 LN, 508, 518, 518C, 528, 528B, 530B, 561D, 571G, 572G, 583K, 594H, 611, 613B, 613C, 613C II, 615C, 621, 621B, 621E, 621R, 623, 623B, 623E, 627, 62...
120G, 12G, 130G, 140B, 140G, 14G, 160G, 16G, 215, 325 LN, 508, 518, 518C, 528, 528B, 530B, 561D, 571G, 572G, 583K, 594H, 611, 613B, 613C, 613C II, 615C, 621, 621B, 621E, 621R, 623, 623B, 623E, 627, 62...
4K9798
EYEBOLT ASSEM.
950, 966C, 980, 980B
950, 966C, 980, 980B
2V5962
EYEBOLT
980B
980B
3T3396
EYEBOLT
3116, 3126, 3126B, 3208, C7
3116, 3126, 3126B, 3208, C7
8N5001
EYEBOLT
3116, 3208, 844, 844H, 854G, 854K, 990 II, 990H, 992G, 992K, 994F
3116, 3208, 844, 844H, 854G, 854K, 990 II, 990H, 992G, 992K, 994F
5L7820
EYEBOLT
3208, 3306, 3406, 3406B, 3408, D333A, D333B, D334, D342, D342C, D343
3208, 3306, 3406, 3406B, 3408, D333A, D333B, D334, D342, D342C, D343
3879865
EYEBOLT
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP, 306E, 307E, 308E, 308E CR, 308E SR, 308E2 CR, 906H2, 907H2, 908H2, 910K, 914K
236D, 242D, 246D, 257D, 259D, 262D, 272D, 272D XHP, 277D, 279D, 287D, 289D, 299D, 299D XHP, 306E, 307E, 308E, 308E CR, 308E SR, 308E2 CR, 906H2, 907H2, 908H2, 910K, 914K
2129421
EYEBOLT AS
TL4 24
TL4 24
2051801
EYEBOLT
TL3 530
TL3 530
4F4403
EYEBOLT
44, D379B, G399
44, D379B, G399
3L9168
EYEBOLT
3181, 3192, 7211, 7231, 7241, 7251, 7261
3181, 3192, 7211, 7231, 7241, 7251, 7261
4C8359
EYEBOLT
3512C, 3516C, 924H, 928H, C175-16, IT28G
3512C, 3516C, 924H, 928H, C175-16, IT28G
3E3879
EYEBOLT
320C FM, 3406C, 3406E, 3412C, 3456, 345C, 3508, 3508B, 3512, 3512B, 3516, 3516B, 5130, 5130B, 5230, 5230B, C18
320C FM, 3406C, 3406E, 3412C, 3456, 345C, 3508, 3508B, 3512, 3512B, 3516, 3516B, 5130, 5130B, 5230, 5230B, C18
1P7407
EYEBOLT
325B L, 330B L, 330C L, 345B II, 345B L, 3606, 3608, 3612, 3616, 910, 916, 926, 930R, 931B, 931C II, 933, 939, D3C II, D3C III, D4C III, D5C III, G3606, G3608, G3612, G3616, IT28, IT28B, R1300, R1300G...
325B L, 330B L, 330C L, 345B II, 345B L, 3606, 3608, 3612, 3616, 910, 916, 926, 930R, 931B, 931C II, 933, 939, D3C II, D3C III, D4C III, D5C III, G3606, G3608, G3612, G3616, IT28, IT28B, R1300, R1300G...
1P7405
EYEBOLT
3606, 3608, 3612, 3616, 583R, 583T, 587R, 587T, 589, 943, 953, D10R, D10T, D10T2, D11N, D11R, D11T, D7H, D8N, D8R, D8R II, D8T, D9R, D9T, G3606, G3608, G3612, G3616, PL83, PL87, R2900G