1104777 FAN AS-REVERSE Caterpillar parts
D10N
Rating:
Alternative (cross code) number:
CA1104777
110-4777
1104777
CA1104777
110-4777
1104777
Weight: 106 pounds 48 kg.
TRACK-TYPE TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 1104777:
Information:
Removal Procedure
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct recovery and charging procedures. Refer to Special Publication, NEDG2500, "Air Conditioning Tools" for the correct tools.
Illustration 1 g02144723
Loosen clamp (2) and remove precleaner assembly (1).
Remove bolts (3) and cover assembly (4).
Illustration 2 g02144727
Disconnect harness assembly (5).
Illustration 3 g02144733
Disconnect hose assemblies (8) and (9).
Disconnect all clamps (10) from refrigerant condenser assembly (7).
Remove bolts (6) and refrigerant condenser assembly (7).
Illustration 4 g02144742
Remove support assembly (11).
Remove refrigerant condenser assembly (7) from support assembly (12).
Illustration 5 g02144761
Remove bolts (15). Separate fan assembly (13) from refrigerant condenser (14). Installation Procedure
Install refrigerant condenser (14) in the reverse order of removal.
Tighten the bolts for hose assemblies (8) and (9) to a torque of 10 2 N m (89 18 lb in). Note: Position the blow out slit of precleaner assembly (1) towards the outside of the machine.
Tighten clamp (2) to a torque of 17 3 N m (150 27 lb in).
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct recovery and charging procedures. Refer to Special Publication, NEDG2500, "Air Conditioning Tools" for the correct tools.
Illustration 1 g02144723
Loosen clamp (2) and remove precleaner assembly (1).
Remove bolts (3) and cover assembly (4).
Illustration 2 g02144727
Disconnect harness assembly (5).
Illustration 3 g02144733
Disconnect hose assemblies (8) and (9).
Disconnect all clamps (10) from refrigerant condenser assembly (7).
Remove bolts (6) and refrigerant condenser assembly (7).
Illustration 4 g02144742
Remove support assembly (11).
Remove refrigerant condenser assembly (7) from support assembly (12).
Illustration 5 g02144761
Remove bolts (15). Separate fan assembly (13) from refrigerant condenser (14). Installation Procedure
Install refrigerant condenser (14) in the reverse order of removal.
Tighten the bolts for hose assemblies (8) and (9) to a torque of 10 2 N m (89 18 lb in). Note: Position the blow out slit of precleaner assembly (1) towards the outside of the machine.
Tighten clamp (2) to a torque of 17 3 N m (150 27 lb in).
Caterpillar parts catalog:
Parts fan Caterpillar catalog:
2138358
FAN GP-SUCTION
D10N, D10R, D10T
D10N, D10R, D10T
2079816
FAN GP-BLOWER
D10N, D10R
D10N, D10R
7W8809
FAN GP-BLOWER
D10N
D10N
9Y5337
FAN GP-BLOWER
D10N
D10N
1852639
FAN AS
1090, 1190, 1190T, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 1290T, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 135H, 135H NA, 1390, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 143H, 14H, 14H NA, 14M,...
1090, 1190, 1190T, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 1290T, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 135H, 135H NA, 1390, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 143H, 14H, 14H NA, 14M,...
1428620
FAN AS-CONDENSER
135H, 135H NA, 143H, 14H, 14H NA, 160H ES, 160H NA, 163H NA, 517, 527, 539, 816F, 816F II, 824G II, 824H, 826C, 826G, 826G II, 826H, 834G, 834H, 836, 836G, 836H, 910G, 914G, 928G, 950H, 953C, 963C, 96...
135H, 135H NA, 143H, 14H, 14H NA, 160H ES, 160H NA, 163H NA, 517, 527, 539, 816F, 816F II, 824G II, 824H, 826C, 826G, 826G II, 826H, 834G, 834H, 836, 836G, 836H, 910G, 914G, 928G, 950H, 953C, 963C, 96...
3994829
FAN AS-CONDENSER
14H, 160H ES, 517, 527, 539, 826G, 826G II, 834H, 836G, 836K, D10N, D10R, D10T, D10T2, D11T, D4H, D4HTSK III, D5HTSK II, D6M, D6R, D6R II, D6R III, D6T, D7R, D7R II, D8R, D8R II, D8T, D9N, D9R, D9T
14H, 160H ES, 517, 527, 539, 826G, 826G II, 834H, 836G, 836K, D10N, D10R, D10T, D10T2, D11T, D4H, D4HTSK III, D5HTSK II, D6M, D6R, D6R II, D6R III, D6T, D7R, D7R II, D8R, D8R II, D8T, D9N, D9R, D9T
1857979
FAN
D10N, D10R, D10T
D10N, D10R, D10T
3812491
FAN AS-CONDENSER
816F, 816F II, 826H, 826K, 834H, 836H, 836K
816F, 816F II, 826H, 826K, 834H, 836H, 836K
2199791
FAN
D9R
D9R
1662941
FAN
321B
321B
5I7594
FAN
320 L
320 L
5150102
FAN
FB221
FB221
7I7696
FAN
322 FM L, 325B
322 FM L, 325B
3589212
FAN AS
D7R XR
D7R XR
4211795
FAN AS-BLOWER
826K, 836K
826K, 836K
2699341
FAN AS
D7E
D7E
1857979
FAN
D10N, D10R, D10T
D10N, D10R, D10T
1359960
FAN AS
D9R
D9R