Machine ECM
The following is a list of Diagnostic Trouble Codes (DTCs) that are associated with the hydraulic lock solenoid of the machine.
Table 1
Machine ECM (MID 299)    
DTC    Code Description    System Response    
1160-3     Hydraulic Lock Solenoid: Voltage Above Normal     Hydraulic lock solenoid will not function.    
1160-6     Hydraulic Lock Solenoid: Current Above Normal     Hydraulic lock solenoid will not function.    
The solenoid is used to shutoff, release, distribute, or mix fluids on the machine. Generally, multiple solenoids are located together on a manifold. The solenoid converts electrical energy into magnetic energy, moving a spool located inside the housing of the valve. A spring is used to hold the spool in position until the solenoid is energized.The magnetic force that acts on the valve spool is created when a coil inside the solenoid is energized.
Possible Causes for an FMI 3 Diagnostic code are:
The solenoid has failed.
The harness is shorted.
The ECM has failed. A failure of the ECM is unlikely.Possible causes for an FMI 6 Diagnostic code are:
The solenoid has failed.
The relay has failed.
The energize circuit of the relay is shorted to ground.
The ECM has failed. A failure of the ECM is unlikely.
Illustration 1 g03329907
Connections of the Hydraulic Lock SolenoidNote: The diagram above is a simplified schematic of the hydraulic lock solenoid connections. The schematic is electrically correct. However, not all of the possible harness connectors are shown. Refer to the latest revision of Electrical Schematic, UENR2694 for the complete schematic.Note: The following test procedure may create other diagnostic trouble codes. Ignore these created diagnostic trouble codes and clear the diagnostic trouble codes when the original diagnostic trouble code has been corrected.Diagnostic Trouble Code Procedure
Note: Prior to beginning this procedure, inspect the harness connectors that are involved in this circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. Check the wiring for pinch points or abrasions. Look for and repair areas that indicate wires are exposed. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing a troubleshooting procedure.
Table 2
Troubleshooting Test Steps    Values    Results    
1. Identify Active FMI Code Associated With Solenoid Circuit    
Code present.     FMI 3 diagnostic code, proceed to Test Step 2.
FMI 6 diagnostic code, proceed to Test Step 5.    
Begin Process For FMI 3 Troubleshooting HERE    
2. Check The Energize Circuit Of The Solenoid For A Short To +Battery Circuit
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connectors from the solenoid and the ECM.
C. At the ECM harness connector, measure the resistance between the solenoid contact (A588-GN) and all contacts used in the ECM connectors.    
Each resistance measurement is greater than 5K Ω.     OK - Each resistance measurement is greater than 5K Ω.
Repair: The solenoid has failed. Replace the solenoid.
Proceed to
The following is a list of Diagnostic Trouble Codes (DTCs) that are associated with the hydraulic lock solenoid of the machine.
Table 1
Machine ECM (MID 299)    
DTC    Code Description    System Response    
1160-3     Hydraulic Lock Solenoid: Voltage Above Normal     Hydraulic lock solenoid will not function.    
1160-6     Hydraulic Lock Solenoid: Current Above Normal     Hydraulic lock solenoid will not function.    
The solenoid is used to shutoff, release, distribute, or mix fluids on the machine. Generally, multiple solenoids are located together on a manifold. The solenoid converts electrical energy into magnetic energy, moving a spool located inside the housing of the valve. A spring is used to hold the spool in position until the solenoid is energized.The magnetic force that acts on the valve spool is created when a coil inside the solenoid is energized.
Possible Causes for an FMI 3 Diagnostic code are:
The solenoid has failed.
The harness is shorted.
The ECM has failed. A failure of the ECM is unlikely.Possible causes for an FMI 6 Diagnostic code are:
The solenoid has failed.
The relay has failed.
The energize circuit of the relay is shorted to ground.
The ECM has failed. A failure of the ECM is unlikely.
Illustration 1 g03329907
Connections of the Hydraulic Lock SolenoidNote: The diagram above is a simplified schematic of the hydraulic lock solenoid connections. The schematic is electrically correct. However, not all of the possible harness connectors are shown. Refer to the latest revision of Electrical Schematic, UENR2694 for the complete schematic.Note: The following test procedure may create other diagnostic trouble codes. Ignore these created diagnostic trouble codes and clear the diagnostic trouble codes when the original diagnostic trouble code has been corrected.Diagnostic Trouble Code Procedure
Note: Prior to beginning this procedure, inspect the harness connectors that are involved in this circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. Check the wiring for pinch points or abrasions. Look for and repair areas that indicate wires are exposed. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing a troubleshooting procedure.
Table 2
Troubleshooting Test Steps    Values    Results    
1. Identify Active FMI Code Associated With Solenoid Circuit    
Code present.     FMI 3 diagnostic code, proceed to Test Step 2.
FMI 6 diagnostic code, proceed to Test Step 5.    
Begin Process For FMI 3 Troubleshooting HERE    
2. Check The Energize Circuit Of The Solenoid For A Short To +Battery Circuit
A. Turn the key start switch and the disconnect switch to the OFF position.
B. Disconnect the machine harness connectors from the solenoid and the ECM.
C. At the ECM harness connector, measure the resistance between the solenoid contact (A588-GN) and all contacts used in the ECM connectors.    
Each resistance measurement is greater than 5K Ω.     OK - Each resistance measurement is greater than 5K Ω.
Repair: The solenoid has failed. Replace the solenoid.
Proceed to
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts fastener Caterpillar catalog:
3562518
FASTENER GP-CEM
C9.3, D6T LGP, D6T XL
C9.3, D6T LGP, D6T XL
3052884
FASTENER GP-FUEL LINES
C15, TH35-C15T
C15, TH35-C15T
3006033
FASTENER GP-OIL COOLER
C15, TH35-C15T
C15, TH35-C15T
3003889
FASTENER GP-OIL COOLER
C15, TH35-C15T
C15, TH35-C15T
2748001
FASTENER GP-OIL COOLER
C15, TH35-C15T
C15, TH35-C15T
2689034
FASTENER GP-OIL PAN
C15, TH35-C15T
C15, TH35-C15T
2960388
FASTENER GP-EXHAUST MANIFOLD
C175-16, C175-20
C175-16, C175-20
2599169
FASTENER GP-WATER LINES
C175-16
C175-16
3643908
FASTENER GP-DAMPER
793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F XQ, C175-16, C175-20
793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F XQ, C175-16, C175-20
2496399
FASTENER GP-DAMPER
C175-16
C175-16
2683625
FASTENER GP-LINES
304C CR, 305C CR
304C CR, 305C CR