3313920 FENDER AS Caterpillar parts
735B, 740B
Rating:
Alternative (cross code) number:
CA3313920
331-3920
3313920
CA3313920
331-3920
3313920
Weight: 304 pounds 137 kg.
ARTICULATED TRUCK, EJECTOR TRUCK,
Information:
Setting The Light Bars
The AccuGrade system has three light bars:
Two vertical light bars for cut and fill mode
One horizontal light bar for left and rightEach light bar can be used in any position, but the light bar must be individually set for that position. You set only one light bar at a time.In order to set the connections for the light bar, perform the following procedure:
Place the display in "Service" mode.
Press the "OK" key (89) and hold the "OK" key (89). Press the "Power" button (85) that is on the display. After the display begins to initialize, release the "OK" key.
Illustration 1 g01317380
At the main screen, press the key that is for "Setup Menu" (70) .The display is set to default to the "Setup Menu - Configuration" screen after the "Setup Menu" key is pressed.
Illustration 2 g01317391
Press the key that is for "Installation" (71) in order to access the selections that are under the "Setup Menu - Installation" screen.
Illustration 3 g01317370
Press the up arrow key or the down arrow key until "Lightbar Connections" is highlighted.
Illustration 4 g01287782
Press the "OK" key (89) . The "Lightbar Connections" screen will be shown on the display.
Connect the light bar for the required position. Disconnect all the other light bars.
Press "SET" for the connected light bar. A pattern of "Light Emitting Diodes" (LEDs) is illuminated on the connected light bar. This should match the pattern that is shown in Illustration 4. If the light bar LEDs are illuminated at the wrong end, press "INVERT".
Disconnect the light bar.
Repeat Steps 6 through 8 in order to set the next two light bars.
Press the "OK" key (89) in order to save the settings and return to the "Setup Menu - Installation" screen.
Press the Escape Key (83) in order to exit the "Setup Menu - Installation". All changes take effect immediately.
When all the light bars are set, reconnect all of the light bars.Note: If the light bars are removed from the machine, each light bar must be reinstalled in the same position. Otherwise, the Light bar Connections will need to be rerun.
The AccuGrade system has three light bars:
Two vertical light bars for cut and fill mode
One horizontal light bar for left and rightEach light bar can be used in any position, but the light bar must be individually set for that position. You set only one light bar at a time.In order to set the connections for the light bar, perform the following procedure:
Place the display in "Service" mode.
Press the "OK" key (89) and hold the "OK" key (89). Press the "Power" button (85) that is on the display. After the display begins to initialize, release the "OK" key.
Illustration 1 g01317380
At the main screen, press the key that is for "Setup Menu" (70) .The display is set to default to the "Setup Menu - Configuration" screen after the "Setup Menu" key is pressed.
Illustration 2 g01317391
Press the key that is for "Installation" (71) in order to access the selections that are under the "Setup Menu - Installation" screen.
Illustration 3 g01317370
Press the up arrow key or the down arrow key until "Lightbar Connections" is highlighted.
Illustration 4 g01287782
Press the "OK" key (89) . The "Lightbar Connections" screen will be shown on the display.
Connect the light bar for the required position. Disconnect all the other light bars.
Press "SET" for the connected light bar. A pattern of "Light Emitting Diodes" (LEDs) is illuminated on the connected light bar. This should match the pattern that is shown in Illustration 4. If the light bar LEDs are illuminated at the wrong end, press "INVERT".
Disconnect the light bar.
Repeat Steps 6 through 8 in order to set the next two light bars.
Press the "OK" key (89) in order to save the settings and return to the "Setup Menu - Installation" screen.
Press the Escape Key (83) in order to exit the "Setup Menu - Installation". All changes take effect immediately.
When all the light bars are set, reconnect all of the light bars.Note: If the light bars are removed from the machine, each light bar must be reinstalled in the same position. Otherwise, the Light bar Connections will need to be rerun.
Caterpillar parts catalog:
Parts fender Caterpillar catalog:
3638613
FENDER GP
735B, 740B
735B, 740B
3110036
FENDER GP
735, 735B, 740, 740B
735, 735B, 740, 740B
2918954
FENDER & SUPPORT GP
735B, 740B
735B, 740B
3313919
FENDER AS
735B, 740B
735B, 740B
3313919
FENDER AS
735B, 740B
735B, 740B
1869353
FENDER AS-REAR
R1600, R1600G, R1600H
R1600, R1600G, R1600H
1869355
FENDER AS-REAR
R1600, R1600G, R1600H
R1600, R1600G, R1600H
1869309
FENDER AS-FRONT
R1600, R1600G, R1600H
R1600, R1600G, R1600H
1869308
FENDER AS-FRONT
R1600, R1600G, R1600H
R1600, R1600G, R1600H
3589520
FENDER AS
777G
777G
4312138
FENDER AS
795F XQ
795F XQ
3799976
FENDER AS
R3000H
R3000H
3799975
FENDER AS
R3000H
R3000H
4418643
FENDER AS
725C, 730C
725C, 730C
4153891
FENDER AS
725C, 730C
725C, 730C