Perform the procedure in Specifications, Systems Operation/Testing and Adjusting, KENR5045, "Relief Valve (Charge) - Test and Adjust" in this module.
Illustration 7 g02078873
Disconnect hose assemblies (1) and (2) from the auger motor. Install Tooling (D), Tool (E), and Tool (F) to the hose assemblies and the auger motor.
Open the access doors on the left side of the machine.
Illustration 8 g02037636
Port "MD" (3) on the left auger pump.
Illustration 9 g02037654
Port "MD" (3) on the right auger pump.
Connect Tool (C) to the forward pressure tap in port "MD" (3) on the left auger pump.
Use Tool (B) in order to connect Tool (C) to Tool (A) .
Illustration 10 g02038842
The Reverse pressure tap in port "MC" (4) on the left auger pump
Illustration 11 g02038844
The Reverse pressure tap in port "MC" (4) on the right auger pump
Connect Tool (C) to the reverse pressure tap in port "MC" (4) .
Use Tool (B) in order to connect Tool (C) to Tool (A) .
Illustration 12 g02038853
Move key start switch (5) to the ON position.
Illustration 13 g02038854
Move engine start switch (6) to the START position. Release the engine start switch after the engine starts.
Move throttle control switch (7) to the HIGH IDLE position. Hold the switch in this position for less than 1 second. The engine speed should increase to 2310 rpm.
Monitor the hydraulic oil temperature with Tool (G). Operate the machine until the oil temperature reaches 43 5.6°C (110 10°F).
Move throttle control switch (7) to the LOW IDLE position. Lower engine rpm to 1200 rpm. Hold the switch in this position until the engine reaches the desired rpm.
Illustration 14 g02038857
Move left auger mode switch (8) to the MANUAL position. Hold the switch in this position for a short time.
Record the pressure at port "MC" (4) as "forward pressure". The pressure should be 35165 to 39302 kPa (5100 to 5700 psi).
Hold left auger mode switch (8) in the MANUAL position. Then, move auger reverse switch (9) to the LEFT AUGER REVERSE position.
Record the pressure at port "MD" (3) as reverse pressure. The pressure should be 35165 to 39302 kPa (5100 to 5700 psi).
Release auger reverse switch (9). Release left auger mode switch (8) .
Move throttle control switch (7) to the LOW IDLE position. Hold the switch in this position for less than 1 second.
After the engine reaches low idle, move engine start switch (6) to the OFF position.
Move key start switch (5) to the OFF position.
Analyze the test results by using the following procedure:
If the forward pressure and the reverse pressure are both within the specified range, the system is operating within design parameters. Go to Step 22.
If either the forward pressure or the reverse pressure is outside the specified range, replace the faulty valve. Retest the pressure.
If the forward pressure and the reverse pressure are both outside the specified range, the case drain flow through the pump may be excessive. Troubleshoot the pump. Retest the pressure.
Remove the Tooling. Connect the hose assemblies to the auger motor. Close the access doors.
Parts filter Caterpillar catalog:
5300635
FILTER
Caterpillar
Caterpillar
5300548
FILTER
Caterpillar
Caterpillar
5300542
FILTER
Caterpillar
Caterpillar
5300541
FILTER
Caterpillar
Caterpillar
5300295
FILTER
Caterpillar
Caterpillar
5300292
FILTER
Caterpillar
Caterpillar
5303501
FILTER-COOLANT
Caterpillar
Caterpillar
5303472
FILTER-FUEL
Caterpillar
Caterpillar
5303441
FILTER
Caterpillar
Caterpillar
5303357
FILTER-FUEL
Caterpillar
Caterpillar
5301016
FILTER
Caterpillar
Caterpillar
5300736
FILTER
Caterpillar
Caterpillar