9F2637 FITTING Caterpillar parts
120G, 120H, 120M, 12G, 12H, 12M, 135H, 140G, 140H, 140K, 140M, 143H, 14H, 160H, 160K, 160M, 163H, 16H, 16M, 301.6C, 302.5, 302.5C, 303.5, 304.5, 312, 3126, 312E, 313B, 314E CR, 316E L, 320E RR, 324E, ...
Rating:
Alternative (cross code) number:
CA9F2637
9F-2637
9F2637
CA9F2637
9F-2637
9F2637
Weight: 0.010 pounds 0 kg.
BACKHOE LOADER, WHEEL TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 9F2637:
Information:
Remote Voltage Control
Partial View Of Regulator
(1) Potentiometer. (2) Jumper. (3) Regulator.Generator output voltage level can be controlled from a remote location. This is done by connecting potentiometer (1) between terminals 6 and 7 on voltage regulator (3). Remove jumper (2) between terminals 4 and 7 for remote voltage level control.For acceptable voltage control, the remote mounted potentiometer must be 10k ohms 5% with three turns and a dielectric strength of 1000 VAC minimum.The terminals of the remote mounted potentiometer are fragile. The wiring connected to remote mounted potentiometer (1) should not have a diameter larger than 18 gauge. Larger diameter wire is not recommended. The wire should be 600 volt class with a 90°C (194°F) insulation. Either jumper (2) or remote potentiometer (1) is required for regulator operation.Manual Voltage Control
Manual Voltage Control Schematic With Power Transformer Manual Voltage Control Schematic With Power Transformer and Sensing
Manual Voltage Control Panel
(1) Switch (OFF, AUTO and MAN positions). (2) Voltage control rheostat. (3) Fuse.The manual voltage control can be used to control generator voltage when there is a failure in the generator regulator assembly. It will manually control the current flow to exciter stator L1.The manual voltage control panel has switch (1) and voltage control rheostat (2) for the manual operating mode.Switch (1) is used to make the selection between AUTO, MAN and OFF. In the "AUTO" position, the VR3 regulator controls the generator voltage. In the "OFF" position, the voltage will go to zero. In the "MAN" position, generator voltage is controlled by voltage control rheostat (2). The Manual Voltage Control Panel must not be installed in a location that is subject to engine vibrations or directly to outside weather. When the manual voltage control is operating in the "Manual" mode, it is not necessary for the VR3 regulator to be connected to the generator. However, the manual control must remain connected to generator sensing lines No. 20 and No. 24.Voltage Droop Transformer And Adjustment Rheostat For Parallel Operation
Generator And Regulator Schematic
(1) Voltage droop transformer. (2) Voltage droop rheostat. (3) Lead. (4) Main stator.Operation of generators in parallel requires voltage droop as reactive load is increased. Droop transformer (1) and adjustment rheostat (2) are required to provide the voltage droop function. The transformer senses load current in lead (3) of main stator (4). Droop rheostat (2) provides adjustment of droop voltage. Rheostat (2) is located directly next to the regulator on the regulator mounting bracket.Transformer (1) is standard on some generators and is an attachment on others. Rheostat (2) is an attachment on all units. Droop transformer (1) is a special ratio transformer. Droop transformer (1) must be installed on generator phase lead T2 with transformer polarity connections as shown.
Partial View Of Regulator
(1) Potentiometer. (2) Jumper. (3) Regulator.Generator output voltage level can be controlled from a remote location. This is done by connecting potentiometer (1) between terminals 6 and 7 on voltage regulator (3). Remove jumper (2) between terminals 4 and 7 for remote voltage level control.For acceptable voltage control, the remote mounted potentiometer must be 10k ohms 5% with three turns and a dielectric strength of 1000 VAC minimum.The terminals of the remote mounted potentiometer are fragile. The wiring connected to remote mounted potentiometer (1) should not have a diameter larger than 18 gauge. Larger diameter wire is not recommended. The wire should be 600 volt class with a 90°C (194°F) insulation. Either jumper (2) or remote potentiometer (1) is required for regulator operation.Manual Voltage Control
Manual Voltage Control Schematic With Power Transformer Manual Voltage Control Schematic With Power Transformer and Sensing
Manual Voltage Control Panel
(1) Switch (OFF, AUTO and MAN positions). (2) Voltage control rheostat. (3) Fuse.The manual voltage control can be used to control generator voltage when there is a failure in the generator regulator assembly. It will manually control the current flow to exciter stator L1.The manual voltage control panel has switch (1) and voltage control rheostat (2) for the manual operating mode.Switch (1) is used to make the selection between AUTO, MAN and OFF. In the "AUTO" position, the VR3 regulator controls the generator voltage. In the "OFF" position, the voltage will go to zero. In the "MAN" position, generator voltage is controlled by voltage control rheostat (2). The Manual Voltage Control Panel must not be installed in a location that is subject to engine vibrations or directly to outside weather. When the manual voltage control is operating in the "Manual" mode, it is not necessary for the VR3 regulator to be connected to the generator. However, the manual control must remain connected to generator sensing lines No. 20 and No. 24.Voltage Droop Transformer And Adjustment Rheostat For Parallel Operation
Generator And Regulator Schematic
(1) Voltage droop transformer. (2) Voltage droop rheostat. (3) Lead. (4) Main stator.Operation of generators in parallel requires voltage droop as reactive load is increased. Droop transformer (1) and adjustment rheostat (2) are required to provide the voltage droop function. The transformer senses load current in lead (3) of main stator (4). Droop rheostat (2) provides adjustment of droop voltage. Rheostat (2) is located directly next to the regulator on the regulator mounting bracket.Transformer (1) is standard on some generators and is an attachment on others. Rheostat (2) is an attachment on all units. Droop transformer (1) is a special ratio transformer. Droop transformer (1) must be installed on generator phase lead T2 with transformer polarity connections as shown.
Cat SIS web machinery list:
Parts fitting Caterpillar catalog:
0046683
FITTING
120M, 140M 2, 14M, 160M 2, 16M, 225, 225D, 227, 229, 229D, 24H, 24M, 30/30, 305.5, 306, 306E, 307, 307B, 307C, 308C, 311, 311B, 311C, 311D LRR, 312, 312B, 312B L, 312D, 312D L, 313B, 313D, 315, 315B, ...
120M, 140M 2, 14M, 160M 2, 16M, 225, 225D, 227, 229, 229D, 24H, 24M, 30/30, 305.5, 306, 306E, 307, 307B, 307C, 308C, 311, 311B, 311C, 311D LRR, 312, 312B, 312B L, 312D, 312D L, 313B, 313D, 315, 315B, ...
1432933
FITTING
3406E, 3456, 385C, 735, 740, C-15, C-16, C-18, C11, C13, C15, C15 I6, C16, C18, C18 I6, CX31-C15I, CX35-P800, D350E II, D400E II, D8R II, PM3456, TH35-C13T, TH35-C15I, TH35-C15T
3406E, 3456, 385C, 735, 740, C-15, C-16, C-18, C11, C13, C15, C15 I6, C16, C18, C18 I6, CX31-C15I, CX35-P800, D350E II, D400E II, D8R II, PM3456, TH35-C13T, TH35-C15I, TH35-C15T
3H0122
FITTING-GREASE
117, 1190T, 1290T, 16, 183, 2391, 24, 2491, 3406E, 3456, 350, 375 L, 44, 46, 518, 522, 522B, 532, 550, 550B, 552, 552 2, 560B, 561B, 561C, 561D, 561H, 570, 570B, 571G, 572G, 574, 580, 580B, 583H, 583K...
117, 1190T, 1290T, 16, 183, 2391, 24, 2491, 3406E, 3456, 350, 375 L, 44, 46, 518, 522, 522B, 532, 550, 550B, 552, 552 2, 560B, 561B, 561C, 561D, 561H, 570, 570B, 571G, 572G, 574, 580, 580B, 583H, 583K...
4H3947
FITTING
16, 561B, 561C, 621, 815, 910, 950, 951B, 955K, 966C, 966R, 977H, 977K, 988B, AD30, AP-1055D, AP-800D, AS2251, AS2252C, AS2301, AS2302, BG-2455D, D5, D6C, D6D, D6E, D7F, D7G, D8N, G353D, R2900, R2900G
16, 561B, 561C, 621, 815, 910, 950, 951B, 955K, 966C, 966R, 977H, 977K, 988B, AD30, AP-1055D, AP-800D, AS2251, AS2252C, AS2301, AS2302, BG-2455D, D5, D6C, D6D, D6E, D7F, D7G, D8N, G353D, R2900, R2900G
1036100
FITTING AS-AIR CONDITIONER
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 163H, 163H NA, 16G, 16H, 16H NA, 24H, 307, 307B, 3...
120G, 120H, 120H ES, 120H NA, 12G, 12H, 12H ES, 12H NA, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 143H, 14H, 14H NA, 160H, 160H ES, 160H NA, 163H, 163H NA, 16G, 16H, 16H NA, 24H, 307, 307B, 3...
8D0538
FITTING
120G, 12G, 130G, 140G, 14G, 160G, 16G, 572G, 613C, 613C II, 615, 615C, 769C, 772, 773B, 777, 910, 931B, 935C II, 939, 988B, D3B, D3C II, D44B, D4B, D4C II, D550B, D5C III
120G, 12G, 130G, 140G, 14G, 160G, 16G, 572G, 613C, 613C II, 615, 615C, 769C, 772, 773B, 777, 910, 931B, 935C II, 939, 988B, D3B, D3C II, D44B, D4B, D4C II, D550B, D5C III
6H9049
FITTING
561B, 583H, 955C, 955H, 977D, 977H, AP-1000B, AP-1055B, AP-600D, AP-650B, AP-655C, AP-655D, AP-800C, AP-800D, AP-900B, AP1000E, AP1055E, AP555E, BG-225B, BG-225C, BG-245C, BG1000E, BG1055E, BG500E, BG...
561B, 583H, 955C, 955H, 977D, 977H, AP-1000B, AP-1055B, AP-600D, AP-650B, AP-655C, AP-655D, AP-800C, AP-800D, AP-900B, AP1000E, AP1055E, AP555E, BG-225B, BG-225C, BG-245C, BG1000E, BG1055E, BG500E, BG...
5B9916
FITTING
120B, 120G, 12G, 130G, 140B, 140G, 14G, 160G, 641, 641B, 657, 657B, 772, 910, 918F, 924F, 930, 930R, 936, 936F, 950B, 950B/950E, 966C, 980, 980B, 988, D8L, D9G, G936, IT12B, IT14B, IT18F, IT24F, PM-20...
120B, 120G, 12G, 130G, 140B, 140G, 14G, 160G, 641, 641B, 657, 657B, 772, 910, 918F, 924F, 930, 930R, 936, 936F, 950B, 950B/950E, 966C, 980, 980B, 988, D8L, D9G, G936, IT12B, IT14B, IT18F, IT24F, PM-20...
3B8484
FITTING
955C, 977D
955C, 977D
2F1336
FITTING
16M, 651E, 785C, 785D, 789C, 789D, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F XQ, 797B, 797F, 955C, 977D
16M, 651E, 785C, 785D, 789C, 789D, 793C, 793D, 793F, 793F AC, 793F CMD, 793F OEM, 793F-XQ, 795F AC, 795F XQ, 797B, 797F, 955C, 977D
8T0336
FITTING-PRESSURE RELIEF
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 14...
120G, 120H, 120H ES, 120H NA, 120K, 120K 2, 120M, 120M 2, 12G, 12H, 12H ES, 12H NA, 12K, 12M, 12M 2, 12M 3, 12M 3 AWD, 130G, 135H, 135H NA, 140G, 140H, 140H ES, 140H NA, 140K, 140K 2, 140M, 140M 2, 14...
2416190
FITTING AS
924G, 924GZ, 924H, 924HZ, 924K, 928HZ, 930G, 930K, 938K, FUSION, H75E S
924G, 924GZ, 924H, 924HZ, 924K, 928HZ, 930G, 930K, 938K, FUSION, H75E S
1P4022
FITTING
1390, 315C, 3208, 583K, 613C, 615, 615C, 943, 953, 963, 963B, 973, D6K XL, D7R II, D8H, D8K, TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
1390, 315C, 3208, 583K, 613C, 615, 615C, 943, 953, 963, 963B, 973, D6K XL, D7R II, D8H, D8K, TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
5W9985
FITTING GP-HYDRAULIC
214B, 224B, 302.5, TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B
214B, 224B, 302.5, TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B
2162283
FITTING-INLET
TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
2159509
FITTING
120M, 12M, 2470C, 3054C, 3054E, 320D GC, 320D L, 323D L, 420E, 430E, 450E, 553C, 559, 613G, 914G, 924H, 924HZ, 928H, 928HZ, 938H, AP-300, AP-300D, AP-600D, AP-650B, AP-655D, AP-800D, AP1000E, AP1055E,...
120M, 12M, 2470C, 3054C, 3054E, 320D GC, 320D L, 323D L, 420E, 430E, 450E, 553C, 559, 613G, 914G, 924H, 924HZ, 928H, 928HZ, 938H, AP-300, AP-300D, AP-600D, AP-650B, AP-655D, AP-800D, AP1000E, AP1055E,...
2159508
FITTING
3054C, 3054E, AP-300, AP-300D, AP-650B, AP-800D, C3.3, C4.4, C7.1, CB-434D, CB-534D, CB-564D, CD-54, CP-433E, CP-533E, CS-323C, CS-423E, CS-433E, CS-533E, PF-300C, PS-150C, PS-360C, TH210, TH215, TH22...
3054C, 3054E, AP-300, AP-300D, AP-650B, AP-800D, C3.3, C4.4, C7.1, CB-434D, CB-534D, CB-564D, CD-54, CP-433E, CP-533E, CS-323C, CS-423E, CS-433E, CS-533E, PF-300C, PS-150C, PS-360C, TH210, TH215, TH22...
2160069
FITTING
621B, 621G, 623G, 627F, 627G, 637D, 637E, 637G, 906, 908, 914G, IT14G, IT14G2, TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
621B, 621G, 623G, 627F, 627G, 637D, 637E, 637G, 906, 908, 914G, IT14G, IT14G2, TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
2295465
FITTING
236B, 242B, 246C, 247B, 252B, 256C, 262C, 262C2, 267B, 268B, 272C, 277C, 279C, 287C, 289C, 297C, 299C, 621G, 623G, 627G
236B, 242B, 246C, 247B, 252B, 256C, 262C, 262C2, 267B, 268B, 272C, 277C, 279C, 287C, 289C, 297C, 299C, 621G, 623G, 627G
2295466
FITTING AS
236B, 242B, 246C, 247B, 252B, 256C, 262C, 262C2, 267B, 268B, 272C, 277C, 279C, 287C, 289C, 297C, 299C, 621G, 623G, 627G
236B, 242B, 246C, 247B, 252B, 256C, 262C, 262C2, 267B, 268B, 272C, 277C, 279C, 287C, 289C, 297C, 299C, 621G, 623G, 627G
2690986
FITTING-COUPLING
422E, 428E, 432E, 434E, 442E, 444E
422E, 428E, 432E, 434E, 442E, 444E
1563631
FITTING AS
416F, 420E, 420F, 422F, 428F, 430E, 430F, 432E, 432F, 434E, 434F, 442E, 444E, 444F, 450E, 450F
416F, 420E, 420F, 422F, 428F, 430E, 430F, 432E, 432F, 434E, 434F, 442E, 444E, 444F, 450E, 450F
1563600
FITTING AS
420E, 430E, 432E, 434E, 442E, 444E, 450E, 450F
420E, 430E, 432E, 434E, 442E, 444E, 450E, 450F
2194562
FITTING
TH220B, TH330B
TH220B, TH330B