Illustration 1 g06072266
Primary Steering Disable Solenoid connections
This diagnostic code is associated with the primary steer (disable) pilot supply solenoid. The FMI 03 diagnostic code means that the ECM has determined that the voltage of the solenoid circuit is above normal.The possible causes of the diagnostic code are listed below:
The solenoid has failed.
The energize circuit of the solenoid is shorted to another voltage source.
The ECM has failed. A failure of the ECM is unlikely.Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.Note: The resistance of the solenoid coil should be 8.7 .4 ohms at 25 °C (77.0 °F).Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connector from the solenoid. Disconnect the machine harness connectors J1 and J2 from the ECM.
At the machine harness ECM connector J2, measure the resistance from contact J2-5 (wire P988-OR(Orange)) to all J1 and J2 contacts that are used on the ECM connectors.Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between wire P988-OR(Orange)and the circuit that has a low-resistance measurement.Repair: Refer to Testing and Adjusting, "Wiring Harness (Short Circuit) - Test" for more information on finding and correcting a short circuit. Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK THE OPERATION OF THE ECMThe disconnect switch and the key start switch remain in the OFF position. The machine harness connectors for the solenoid and the ECM remain disconnected.
At the machine harness connector J2 for the ECM, use a 151-6320 Removal Tool to remove the solenoid energize wire P988-OR(Orange)and socket at contact J2-5 from the harness connector.
Reconnect the machine harness J1 and J2 connectors to the ECM.
Turn the disconnect switch and the key start switch to the ON position.
Observe the status of the active CID 2177 FMI 03 diagnostic code.Expected Result:The CID 2177 FMI 03 diagnostic code is no longer active. A CID 2177 FMI 05 diagnostic code is now active.Results:
YES - The CID 2177 FMI 03 diagnostic code is no longer active. A CID 2177 FMI 05 diagnostic code has been activated after the solenoid energize circuit was disconnected. The ECM has responded correctly to the open circuit condition in the solenoid circuit. Reinstall the
Caterpillar parts catalog:
Parts floor Caterpillar catalog:
4287817
FLOOR MAT
Caterpillar
Caterpillar
4842278
FLOOR MAT
Caterpillar
Caterpillar
4842277
FLOOR MAT
Caterpillar
Caterpillar
4944856
FLOOR MAT
Caterpillar
Caterpillar
4733674
FLOOR AS
Caterpillar
Caterpillar
4730149
FLOOR
Caterpillar
Caterpillar
4719224
FLOOR MAT AS
Caterpillar
Caterpillar
4699417
FLOOR MAT
Caterpillar
Caterpillar
5063790
FLOOR MAT
Caterpillar
Caterpillar
5063789
FLOOR MAT
Caterpillar
Caterpillar
5046746
FLOOR MAT GP
Caterpillar
Caterpillar
4475109
FLOOR MAT
Caterpillar
Caterpillar