Information:
Test For A Short Circuit
Table 1
Troubleshooting Test Steps Values Results
1. Identify Short Circuit.
A. Identify the connectors and the wire numbers of the suspect circuits. Use the Electrical System Schematic of the machine to identify the circuits.
B. Turn the key start switch and the disconnect switch to OFF.
C. Disconnect the component and the ECM from the wiring harness.
D. At the machine harness connector for the ECM, place one of the multimeter probes on the contact of the suspect wire.
E. Use the other multimeter probe to check the resistance across all other contacts in the connectors of the ECM and frame ground.
The resistance is greater than 5K Ω for all the readings. OK - The harness circuits are correct.
STOP
NOT OK - The resistance is less than 5 Ω. There is a short in the machine harness. The short is between the suspected wire and the wire with the lowest resistance measurement.
Repair: Repair or replace the machine harness.
Note: A resistance that is greater than 5 Ω but less than 5K Ω would indicate a loose connection or a corroded connection in the circuit. A resistance measurement that is greater than 5K Ω would indicate an open in the circuit.
STOP
Table 1
Troubleshooting Test Steps Values Results
1. Identify Short Circuit.
A. Identify the connectors and the wire numbers of the suspect circuits. Use the Electrical System Schematic of the machine to identify the circuits.
B. Turn the key start switch and the disconnect switch to OFF.
C. Disconnect the component and the ECM from the wiring harness.
D. At the machine harness connector for the ECM, place one of the multimeter probes on the contact of the suspect wire.
E. Use the other multimeter probe to check the resistance across all other contacts in the connectors of the ECM and frame ground.
The resistance is greater than 5K Ω for all the readings. OK - The harness circuits are correct.
STOP
NOT OK - The resistance is less than 5 Ω. There is a short in the machine harness. The short is between the suspected wire and the wire with the lowest resistance measurement.
Repair: Repair or replace the machine harness.
Note: A resistance that is greater than 5 Ω but less than 5K Ω would indicate a loose connection or a corroded connection in the circuit. A resistance measurement that is greater than 5K Ω would indicate an open in the circuit.
STOP
Caterpillar SIS machinery equipment:
Caterpillar SIS
769B TRUCK 99F01031-03453 (MACHINE) »
8J-0276
FLOW CONTROL VALVE GROUP
768B TRACTOR 79S00001-UP (MACHINE) POWERED BY D343 ENGINE »
8J-0276
FLOW CONTROL VALVE GROUP
769B TRUCK 99F03454-UP (MACHINE) POWERED BY D343 ENGINE »
8J-0276
FLOW CONTROL VALVE GROUP
769B TRUCK 35W00001-UP (MACHINE) »
8J-0276
FLOW CONTROL VALVE GROUP
Caterpillar parts catalog:
Parts flow Caterpillar catalog:
4J4646
FLOW CONTROL VALVE GROUP
824, 834
824, 834
8M6347
FLOW CONTROL VALVE GROUP
571G, 572G, 977K, D6C, D7F, D7G
571G, 572G, 977K, D6C, D7F, D7G
7J6219
FLOW CONTROL VALVE GROUP
772, 773
772, 773
5J1641
FLOW CONTROL VALVE GROUP
824, 824B, 834
824, 824B, 834
7J2231
FLOW CONTROL AND RELIEF VALVE GROUP
631C, 637, 641B, 657B
631C, 637, 641B, 657B