4913164 FLYWHEEL AS Caterpillar parts
Rating:
Alternative (cross code) number:
CA4913164
491-3164
4913164
CA4913164
491-3164
4913164
Information:
Engines:
3606 (S/N: 8RB)
3608 (S/N: 6MC)
3612 (S/N: 9RC; 9FR; 2NZ)
3616 (S/N: 1PD; 1FN)
Reference: Systems Operation, Testing and Adjusting, and Troubleshooting, RENR2490, "Marine Monitoring System II for 3600 Engines"Reference: Systems Operation, Testing and Adjusting, and Troubleshooting, RENR2491, "Generator Monitoring System For 3600 Engines"Reference: Electrical System Schematic, RENR2459, "3600 Marine Monitoring System II (MMS-II) and GMS Electical Schematic"The previous Marine Monitoring System II (MMS II) and Generator Monitoring System (GMS) used Ethernet as a communication link. The current systems use DH + mode as the communication link.Most of these systems were ordered with options that required the conversion to DH + mode. When these systems were converted to DH + mode, that communication link made the most common configuration standard. Using DH + mode allows the computer serial port to be used as a connection point for input into the service diagnostic mode for troubleshooting. Using the serial port on the CPU allows a service technician to troubleshoot systems without temporarily disconnecting the local display.The part numbers for the system components have been updated in order to work with the DH + mode of communications. In the 179-8801 Control Panel Gp, the 190-0330 Module is replaced by the 159-3031 Module. In the 179-8802 Instrument Panel Gp, the 162-0616 Monitor is replaced by the 168-4672 Module .The Ethernet is still available for use as a communication link. A Custom Quote Request can be obtained by sending an e-mail to Caterpillar at lecservicesupport.
3606 (S/N: 8RB)
3608 (S/N: 6MC)
3612 (S/N: 9RC; 9FR; 2NZ)
3616 (S/N: 1PD; 1FN)
Reference: Systems Operation, Testing and Adjusting, and Troubleshooting, RENR2490, "Marine Monitoring System II for 3600 Engines"Reference: Systems Operation, Testing and Adjusting, and Troubleshooting, RENR2491, "Generator Monitoring System For 3600 Engines"Reference: Electrical System Schematic, RENR2459, "3600 Marine Monitoring System II (MMS-II) and GMS Electical Schematic"The previous Marine Monitoring System II (MMS II) and Generator Monitoring System (GMS) used Ethernet as a communication link. The current systems use DH + mode as the communication link.Most of these systems were ordered with options that required the conversion to DH + mode. When these systems were converted to DH + mode, that communication link made the most common configuration standard. Using DH + mode allows the computer serial port to be used as a connection point for input into the service diagnostic mode for troubleshooting. Using the serial port on the CPU allows a service technician to troubleshoot systems without temporarily disconnecting the local display.The part numbers for the system components have been updated in order to work with the DH + mode of communications. In the 179-8801 Control Panel Gp, the 190-0330 Module is replaced by the 159-3031 Module. In the 179-8802 Instrument Panel Gp, the 162-0616 Monitor is replaced by the 168-4672 Module .The Ethernet is still available for use as a communication link. A Custom Quote Request can be obtained by sending an e-mail to Caterpillar at lecservicesupport.
Caterpillar parts catalog:
Parts flywheel Caterpillar catalog:
4518299
FLYWHEEL GP
Caterpillar
Caterpillar
4512961
FLYWHEEL AS
Caterpillar
Caterpillar
3980923
FLYWHEEL AS
Caterpillar
Caterpillar
4612951
FLYWHEEL
Caterpillar
Caterpillar
4589705
FLYWHEEL AS
Caterpillar
Caterpillar
3999467
FLYWHEEL GP
Caterpillar
Caterpillar
3739415
FLYWHEEL AS
Caterpillar
Caterpillar
3739414
FLYWHEEL AS
Caterpillar
Caterpillar
5620287
FLYWHEEL AS
Caterpillar
Caterpillar
5620286
FLYWHEEL GP
Caterpillar
Caterpillar
5442384
FLYWHEEL
Caterpillar
Caterpillar
4940343
FLYWHEEL AS
Caterpillar
Caterpillar