Information:
The following conditions must exist before any of the above codes will become active:
There are no active 678 or 41 codes.
There are no active 168 codes.
Illustration 1 g06308418
Schematic diagram for the PWM sensors
Table 2
Troubleshooting Test Steps Values Results
1. Inspect Electrical Connectors and Wiring
A. Thoroughly inspect the terminal connections on the P2/J2 and P1/J1 ECM connectors and the PWM sensors.
Refer to Troubleshooting, "Electrical Connectors - Inspect".
B. Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector and the sensor connectors that are associated with the active diagnostic code.
C. Check the screw for the ECM connector for the correct torque of 6 N m (53 lb in).
D. Check the harness for corrosion, abrasion, and pinch points from the sensors to the ECM.
Loose connection or damaged wire
Result: There is a fault in a connector or the wiring.
Repair: Repair any faulty connectors or replace the wiring harness. Ensure that all the seals are properly in place and ensure that the connectors are correctly coupled.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: All connectors, pins, and sockets are correctly coupled and/or inserted. The harness is free of corrosion, abrasion, and pinch points.
Proceed to Test Step 2.
2. Check For Active Diagnostic Codes
A. Turn the keyswitch to the OFF position.
B. Connect the electronic service tool to the diagnostic connector.
C. Turn the keyswitch to the ON position. Wait at least 10 seconds for activation of the diagnostic codes.
D. Verify if any of the diagnostic codes that are listed in Table 1 are active.
E. Turn the keyswitch to the OFF position.
Diagnostic codes
Result: There are no active diagnostic codes for the PWM sensors.
Repair: If there are logged diagnostic codes for the PWM sensors, the fault may be intermittent.
Refer to Troubleshooting, "Electrical Connectors - Inspect" to identify intermittent faults.
Result: A diagnostic code that is listed in Table 1 is active.
Proceed to Test Step 3.
3. Check the Supply Voltage at the Sensor Connector
A. Turn the keyswitch to the OFF position.
B. Disconnect the connector for the suspect sensor.
C. Turn the keyswitch to the ON position. Do not start the engine.
D. Measure the voltage between the supply terminal and the ground terminal on the harness connector for the suspect sensor. The voltage measurement should be 8.0 0.2 VDC.
E. Turn the keyswitch to the OFF position.
F. Reconnect the sensor.
8.0 0.2 V
Result: The voltage measurement is not within the expected range. The fault is in the supply wire or the ground wire in the engine wiring harness.
Repair: Repair the faulty wiring or replace the faulty wiring.
Use the electronic service tool to clear all logged diagnostic codes. Return the engine to service.
Result: The voltage measurement is within the expected range - The correct supply voltage is reaching the sensor.
Proceed to Test Step 4.
4. Check the Type of Diagnostic Code that is Active
A. Turn the keyswitch to the ON position. Wait at least 10 seconds for activation of the diagnostic codes.
B. Use the electronic service tool to
There are no active 678 or 41 codes.
There are no active 168 codes.
Illustration 1 g06308418
Schematic diagram for the PWM sensors
Table 2
Troubleshooting Test Steps Values Results
1. Inspect Electrical Connectors and Wiring
A. Thoroughly inspect the terminal connections on the P2/J2 and P1/J1 ECM connectors and the PWM sensors.
Refer to Troubleshooting, "Electrical Connectors - Inspect".
B. Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector and the sensor connectors that are associated with the active diagnostic code.
C. Check the screw for the ECM connector for the correct torque of 6 N m (53 lb in).
D. Check the harness for corrosion, abrasion, and pinch points from the sensors to the ECM.
Loose connection or damaged wire
Result: There is a fault in a connector or the wiring.
Repair: Repair any faulty connectors or replace the wiring harness. Ensure that all the seals are properly in place and ensure that the connectors are correctly coupled.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: All connectors, pins, and sockets are correctly coupled and/or inserted. The harness is free of corrosion, abrasion, and pinch points.
Proceed to Test Step 2.
2. Check For Active Diagnostic Codes
A. Turn the keyswitch to the OFF position.
B. Connect the electronic service tool to the diagnostic connector.
C. Turn the keyswitch to the ON position. Wait at least 10 seconds for activation of the diagnostic codes.
D. Verify if any of the diagnostic codes that are listed in Table 1 are active.
E. Turn the keyswitch to the OFF position.
Diagnostic codes
Result: There are no active diagnostic codes for the PWM sensors.
Repair: If there are logged diagnostic codes for the PWM sensors, the fault may be intermittent.
Refer to Troubleshooting, "Electrical Connectors - Inspect" to identify intermittent faults.
Result: A diagnostic code that is listed in Table 1 is active.
Proceed to Test Step 3.
3. Check the Supply Voltage at the Sensor Connector
A. Turn the keyswitch to the OFF position.
B. Disconnect the connector for the suspect sensor.
C. Turn the keyswitch to the ON position. Do not start the engine.
D. Measure the voltage between the supply terminal and the ground terminal on the harness connector for the suspect sensor. The voltage measurement should be 8.0 0.2 VDC.
E. Turn the keyswitch to the OFF position.
F. Reconnect the sensor.
8.0 0.2 V
Result: The voltage measurement is not within the expected range. The fault is in the supply wire or the ground wire in the engine wiring harness.
Repair: Repair the faulty wiring or replace the faulty wiring.
Use the electronic service tool to clear all logged diagnostic codes. Return the engine to service.
Result: The voltage measurement is within the expected range - The correct supply voltage is reaching the sensor.
Proceed to Test Step 4.
4. Check the Type of Diagnostic Code that is Active
A. Turn the keyswitch to the ON position. Wait at least 10 seconds for activation of the diagnostic codes.
B. Use the electronic service tool to
Caterpillar parts catalog:
Parts fork Caterpillar catalog:
4M9076
FORK
12E
12E
7M4613
FORK
12E, 955H, 977H
12E, 955H, 977H
4F4763
FORK
120B, 12E, 140, 140B
120B, 12E, 140, 140B
3D2405
FORK
120B, 12E, 140, 140B
120B, 12E, 140, 140B
3D2404
FORK
120B, 12E, 140, 140B
120B, 12E, 140, 140B
2D9639
FORK
12E
12E
4D2698
FORK
120B, 12E, 140B
120B, 12E, 140B
4D2704
FORK
120B, 12E, 140B
120B, 12E, 140B
4D2703
FORK
120B, 12E, 140B
120B, 12E, 140B
8D7811
FORK
120B, 140B
120B, 140B
4D2703
FORK
120B, 12E, 140B
120B, 12E, 140B
4D2704
FORK
120B, 12E, 140B
120B, 12E, 140B
4D2698
FORK
120B, 12E, 140B
120B, 12E, 140B
4D8411
FORK
16
16
8D0756
FORK
16
16
5232119
FORK
Caterpillar
Caterpillar
0861209
FORK, UNDER
E200B
E200B
0861210
FORK, UNDER
E200B
E200B
G22010700
FORK
Caterpillar
Caterpillar