1002941 FUEL SYSTEM Caterpillar parts
320 L, 325 L, 325 LN, 928F, 950F, 950F II, 953B, D250D, IT28F
Rating:
Alternative (cross code) number:
CA1002941
100-2941
1002941
CA1002941
100-2941
1002941
Weight: 0.010 pounds 0 kg.
ARTICULATED TRUCK, WHEEL LOADER,
Related part:
1002941
GASKET KT-YM
3931020
CL
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
1002941 Gasket KIT (New AFTERMARKET) - G&T Engine Parts
G&T Engine Parts Fits equipment: ARTICULATED DUMP TRUCK: D20D, D250D; ENGINE - MACHINE: 3116, 3126; EXCAVATOR: 320, 320 L, 320N, 320S, 325, 325L, 325 LN; INTEGRATED TOOLCARRIER: IT28F; WHEEL-TYPE LOADER: 950F II, 950F, 928F. || Condition: NEW AFTERMARKET || Weight: 0.44 lbs || Use of any OEM manufacturer name is not intended to represent any relationship between the two companies, instead it indicates that we sell replacement parts that are compatible with OEM components.
G&T Engine Parts Fits equipment: ARTICULATED DUMP TRUCK: D20D, D250D; ENGINE - MACHINE: 3116, 3126; EXCAVATOR: 320, 320 L, 320N, 320S, 325, 325L, 325 LN; INTEGRATED TOOLCARRIER: IT28F; WHEEL-TYPE LOADER: 950F II, 950F, 928F. || Condition: NEW AFTERMARKET || Weight: 0.44 lbs || Use of any OEM manufacturer name is not intended to represent any relationship between the two companies, instead it indicates that we sell replacement parts that are compatible with OEM components.
$89.89
13 Feb 2024
US: Fast 404
1002941 Gaskett Kit Fits CATERPILLARR Models
BSlocator High-quality OEM and aftermarket parts for tractors and other agricultural machinery || Comprehensive repair kits with all necessary components for quick and easy maintenance || High-quality materials used for long-lasting performance and durability || Reliable repair parts and maintenance kits for efficient upkeep and long-lasting operation of equipment || Part Number: 1002941
BSlocator High-quality OEM and aftermarket parts for tractors and other agricultural machinery || Comprehensive repair kits with all necessary components for quick and easy maintenance || High-quality materials used for long-lasting performance and durability || Reliable repair parts and maintenance kits for efficient upkeep and long-lasting operation of equipment || Part Number: 1002941
Compatible equipment models: 1002941:
Information:
System Operation Description:The following information must be known and recorded for paralleling operations. The information must be obtained at various load points. The information must match the generator readings.
Verify breaker outputs voltage
Current
Power
Power factor readingsThe following are what is expected:
Voltages are close to rated values
Readings from the EMCP and the CDVR match
No voltage exists on the output of the open breaker
Metering at various load points match the power analyzer readings
Metering at the output of breaker matches metering at input of breaker for paralleling
All power readings are positiveIf the expected data is not correct, then the following must be confirmed:
Confirm that the configuration is correct for the EMCP generator current transformers and the potential transformers.
Ensure that settings in the EMCP and the CDVR match
Check for correct wiring.
If negative kW is seen, check for correct CT polarityA non-adjustable and non-programmable shutdown immediately occurs when the generator breaker is closed and there is a generator sensing fault. This shutdown occurs when a phase difference (non-zero) between phase A on the generator and phase A on the bus is detected. An immediate shutdown test also occurs for the other phases.Test Step 1. Test Dead Bus Arbitration Wiring
Use a digital multimeter to verify continuity or voltages between the following points. Note: The generator set must be off.
Pin 24 on 70-pin/DBA-1 terminal
Pin 25 on 70-pin/DBA-2 terminal
Pin 6 on 70-pin/DBA-3 terminal
Pin 7 on 70-pin/DBA-4 terminal
Pin 26 on 70-pin/PIO-REF terminal
Verify battery voltage on the "Best Battery Positive Line" diode cathode.
Verify that 0 VDC exist across the DBA relay coil that is located in the terminal box.
If multiple generator sets are wired together, then verify the continuity between the following points.
DBA-1 terminals on all generator sets
DBA-2 terminals on all generator sets
DBA-3 terminals on all generator sets
DBA-4 terminals on all generator sets
PIO-REF terminals on all generator sets
Cathodes of the "Best Battery Positive Line" diodes on all generator setsExpected Result:The continuity or voltage exists between the test points.Results:
OK - The appropriate continuity or voltage exists between all of the test points.STOP
Not OK - The appropriate continuity or voltage does not exist between all of the test points.Repair: Repair the Wiring. Verify that the problem has been corrected. The generator set operates normally.STOP
Verify breaker outputs voltage
Current
Power
Power factor readingsThe following are what is expected:
Voltages are close to rated values
Readings from the EMCP and the CDVR match
No voltage exists on the output of the open breaker
Metering at various load points match the power analyzer readings
Metering at the output of breaker matches metering at input of breaker for paralleling
All power readings are positiveIf the expected data is not correct, then the following must be confirmed:
Confirm that the configuration is correct for the EMCP generator current transformers and the potential transformers.
Ensure that settings in the EMCP and the CDVR match
Check for correct wiring.
If negative kW is seen, check for correct CT polarityA non-adjustable and non-programmable shutdown immediately occurs when the generator breaker is closed and there is a generator sensing fault. This shutdown occurs when a phase difference (non-zero) between phase A on the generator and phase A on the bus is detected. An immediate shutdown test also occurs for the other phases.Test Step 1. Test Dead Bus Arbitration Wiring
Use a digital multimeter to verify continuity or voltages between the following points. Note: The generator set must be off.
Pin 24 on 70-pin/DBA-1 terminal
Pin 25 on 70-pin/DBA-2 terminal
Pin 6 on 70-pin/DBA-3 terminal
Pin 7 on 70-pin/DBA-4 terminal
Pin 26 on 70-pin/PIO-REF terminal
Verify battery voltage on the "Best Battery Positive Line" diode cathode.
Verify that 0 VDC exist across the DBA relay coil that is located in the terminal box.
If multiple generator sets are wired together, then verify the continuity between the following points.
DBA-1 terminals on all generator sets
DBA-2 terminals on all generator sets
DBA-3 terminals on all generator sets
DBA-4 terminals on all generator sets
PIO-REF terminals on all generator sets
Cathodes of the "Best Battery Positive Line" diodes on all generator setsExpected Result:The continuity or voltage exists between the test points.Results:
OK - The appropriate continuity or voltage exists between all of the test points.STOP
Not OK - The appropriate continuity or voltage does not exist between all of the test points.Repair: Repair the Wiring. Verify that the problem has been corrected. The generator set operates normally.STOP
Caterpillar parts catalog:
Parts fuel Caterpillar catalog:
1278216
FUEL INJECTOR GROUP
120H, 120H ES, 120H NA, 135H, 135H NA, 3116, 320B, 322B, 322B L, 322B LN, 322C, 322C FM, 325B, 325B L, 446B, 446D, 539, 561M, 613C II, 924F, 928G, 938F, 938G, 950F, 950F II, 953C, 963B, 963C, AP-1000,...
120H, 120H ES, 120H NA, 135H, 135H NA, 3116, 320B, 322B, 322B L, 322B LN, 322C, 322C FM, 325B, 325B L, 446B, 446D, 539, 561M, 613C II, 924F, 928G, 938F, 938G, 950F, 950F II, 953C, 963B, 963C, AP-1000,...
1077733
FUEL INJECTOR
120H, 120H ES, 120H NA, 135H, 135H NA, 3116, 320B, 322B L, 322B LN, 325B L, 446B, 613C II, 924F, 928G, 938F, 950F II, 953C, 963B, AP-1000, AP-1050, CB-634C, CP-563, CS-531, CS-531C, CS-533C, CS-563C, ...
120H, 120H ES, 120H NA, 135H, 135H NA, 3116, 320B, 322B L, 322B LN, 325B L, 446B, 613C II, 924F, 928G, 938F, 950F II, 953C, 963B, AP-1000, AP-1050, CB-634C, CP-563, CS-531, CS-531C, CS-533C, CS-563C, ...
4P5746
FUEL RATIO CONTROL
211B, 3114, 3116, 3126, 320 L, 322, 322 FM L, 322 LN, 322B, 322B L, 325, 325 L, 325 LN, 325B, 325B L, 613C II, 918F, 950F, 950F II, BG-2455C, BG-245C, E120B, E240C, IT18F, M318, M320
211B, 3114, 3116, 3126, 320 L, 322, 322 FM L, 322 LN, 322B, 322B L, 325, 325 L, 325 LN, 325B, 325B L, 613C II, 918F, 950F, 950F II, BG-2455C, BG-245C, E120B, E240C, IT18F, M318, M320
2U6521
FUEL TANK GP.
D250D
D250D
7U9543
FUEL LINES GP.
D250D
D250D
7X7658
FUEL SYSTEM
931C, 931C II, 935C, D3C II, D4C, D4C II, D4H, D4HTSK II, E180
931C, 931C II, 935C, D3C II, D4C, D4C II, D4H, D4HTSK II, E180
6V4780
FUEL SYSTEM
950B, 950B/950E, 963
950B, 950B/950E, 963
6V4720
FUEL SYSTEM
910, 931B, 953, D3B
910, 931B, 953, D3B
5P9948
FUEL SYSTEM
910, 931, 931B, 943, D3, D3B
910, 931, 931B, 943, D3, D3B
9X2061
FUEL SYSTEM
966R, D6D
966R, D6D
3Y8809
FUEL SYSTEM
977L, D6D
977L, D6D
3Y8800
FUEL SYSTEM
920, 955L, D4E
920, 955L, D4E