Illustration 1 g03715932
Rear cover removed for clarity
(1) Evaporator sensor Diagnostics
Illustration 2 g03717766
Partial electrical schematic
(A) Connector
(B) Connector
(C) Connector
(D) Connector
(1) Evaporator sensor
Disconnect evaporator sensor (1) connector from connector (D). Measure the value of the resistance in the evaporator sensor. See "Specifications" for the correct resistance value. Proceed to Step 2.
If the resistance value is incorrect see, Step 3. If the resistance value is correct, see Step 4.
Replace the evaporator sensor.
Measure the voltage between the "GY/YL" wire and the "BK/YL" wire at connector (N). See "Specifications" for the correct voltage. Proceed to Step 5.
If the voltage value is incorrect, see Step 6. If the voltage value is correct, see Step 7.
Disconnect connector (C) from connector (B). Check the wiring harness between connector (D) and connector (C). Repair the wiring harness if faulty. Also, check the system power source. Refer to Systems Operation, "Air Conditioning System Electrical Schematic".
Reconnect the evaporator sensor connector to connector (D). Measure the voltage between "GY/YL" wire and the "BK/YL" wire at connector (B). See "Specifications" for the correct voltage. Proceed to Step 8.
If the voltage value is incorrect, see Step 9. If the voltage value is correct, see Step 10.
Disconnect connector (A) from the control panel. Check the wiring harness between connector (B) and connector (A). Repair the wiring harness if faulty.
Reconnect connector (C) to connector (B). Measure the voltage between the "GY/YL" wire and the "BK/YL" wire at the control panel. If the voltage value is incorrect, replace the control panel. Specifications
Illustration 3 g02316016
Evaporator sensor thermal characteristics
(R) Resistance (k Ohms)
(T) Temperature Resistance in the evaporator sensor 0 °C (32 °F) ... 1.645 kΩ 25 °C (77 °F) ... 5 kΩVoltage between connectors ... 5.0 VVoltage between terminals 10 °C (50 °F) ... 1.83 V 20 °C (68 °F) ... 1.34 V 25 °C (77 °F) ... 1.13 V 30 °C (86. °F) ... 0.96 V
Parts gage Caterpillar catalog:
1U5793
GAGE-PRESS DIF
Caterpillar
Caterpillar
1U5751
GAGE-TIRE
Caterpillar
Caterpillar
1U5481
GAGE GP
Caterpillar
Caterpillar
1U5469
GAGE-PRESSURE
Caterpillar
Caterpillar
1U5425
GAGE A-TIMING
Caterpillar
Caterpillar
1U5148
GAGE-PRESSURE
Caterpillar
Caterpillar
1U7324
GAGE AS-
Caterpillar
Caterpillar
1U7046
GAGE-TORQUE
Caterpillar
Caterpillar
1U6432
GAGE AS-PLUG
Caterpillar
Caterpillar
1U6431
GAGE GP -
Caterpillar
Caterpillar
1U6314
GAGE G-SEAL
Caterpillar
Caterpillar
1U6148
GAGE
Caterpillar
Caterpillar