7C3389 GAGE-OIL LEVEL Caterpillar parts
Rating:
Alternative (cross code) number:
CA7C3389
7C-3389
7C3389
CA7C3389
7C-3389
7C3389
Weight: 0.30 pounds 0 kg.
Information:
Illustration 1 g01943597
Schematic of the action alarm
This diagnostic code is associated with the action alarm. The FMI 06 means that the ECM has determined that the current of the alarm circuit is above normal or grounded to the circuit. The possible causes of this diagnostic code are listed below:
The energize circuit of the alarm is shorted to ground.
The alarm has failed.
The ECM has failed. This is unlikely. Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0271 FMI 06 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.Test Step 1. CHECK THE ALARM.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Observe the status of the diagnostic code.
Disconnect the alarm with the active diagnostic code from the machine harness. Expected Result:The CID 0271 FMI 06 diagnostic code changes to a CID 0271 FMI 05 diagnostic code when the alarm is disconnected.Results:
YES - The CID 0271 FMI 06 diagnostic code changes to a CID 0271 FMI 05 diagnostic code when the alarm is disconnected. The circuit is correct.Repair: The alarm has failed. Repeat this test "CHECK THE ALARM" in order to verify the failure of the alarm. Replace the alarm.STOP
NO - The CID 0271 FMI 06 diagnostic code remains active. Proceed to Test Step 2.Test Step 2. CHECK THE ENERGIZE CIRCUIT OF THE ALARM FOR A SHORT TO GROUND.
Turn the key start switch and the disconnect switch to the OFF position.
The alarm remains disconnected from the machine harness.
Disconnect the machine harness connector(s) from the ECM.
At the machine harness connector, measure the resistance from the signal contact IC-23 (wire 410-WH(White)) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms.Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 3.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between IC-23 (wire 410-WH(White)) and the circuit with the low resistance measurement.Repair: Repair the machine harness or replace the machine harness. STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the harness connectors and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Check the status of the CID 0271 FMI 06 diagnostic code. Expected Result:The CID 0271 FMI 06 diagnostic code is active. Results:
YES - The CID 0271 FMI 06 diagnostic code is active. The diagnostic code has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Troubleshooting, "Electronic
Parts gage Caterpillar catalog:
7C2790
GAGE
Caterpillar
Caterpillar
7C0940
GAGE G-O/L
Caterpillar
Caterpillar
7B8695
GAGE
Caterpillar
Caterpillar
7B8120
GAGE A
Caterpillar
Caterpillar
7B3126
GAGE
Caterpillar
Caterpillar
7B1830
GAGE A.
Caterpillar
Caterpillar
7C7767
GAGE GP-
Caterpillar
Caterpillar
7C7187
GAGE-OIL LEVEL
Caterpillar
Caterpillar
7C6369
GAGE AS-
Caterpillar
Caterpillar
7C6099
GAGE A
Caterpillar
Caterpillar
7C5622
GAGE
Caterpillar
Caterpillar
7C4056
GAGE
Caterpillar
Caterpillar