1083515 GASKET-PLUG Caterpillar parts
CG137-08, CG137-12, D379B, G3304, G3304B, G3306, G3306B, G3406, G3408, G3408B, G3408C, G3412, G3412C, G3606, G3606B, G3608, G3612, G3616
Rating:
Alternative (cross code) number:
CA1083515
108-3515
1083515
CA1083515
108-3515
1083515
Weight: 0.01 pounds 0 kg.
GAS ENGINE, GENERATOR SET,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$43.99
10 May 2023
US: OLIMIE
Replacement For Compatible With 1083515 Gasket-Plug Fits Caterpillar Models
ZAKAY
ZAKAY
This part in 5 request:
Show.
This information for suppliers only!
2025-01-21
2025-01-20
2024-11-22
2019-02-19
2018-05-31
Compatible equipment models: 1083515:
Information:
There have been some problems on a few of the earlier infrared thermometers. It has been reported that the barrel can become loose on some infrared thermometers. To tighten the barrel, first remove the decal on the lower side of the barrel, just in front of the trigger. Loosen the screw that is under this decal and move the barrel back into position. Tighten the screw and put the decal back in position on the barrel.
There have also been reports that some tests have not been accurate because of infrared energy reflected from other objects. This reflected infrared energy, which can be reflected in the same way that light is, can cause a temperature indication that is too high on the object being tested. These reflections can come from or be the result of a shiny surface, electric lights, the sun or a heat source too close to the object to be tested. Other objects that can give a wrong indication are polished (smooth) painted surfaces or shiney metal surfaces such as hydraulic cylinder rods or stainless steel exhaust stacks.
For example, on some marine engines the aftercooler water line can be near the exhaust manifold. If the water line is tested, the infrared energy from the exhaust manifold will increase the temperature indication of the water line.
Several methods can be used to limit this reflected infrared energy. One way is to put masking tape on the area of the object to be tested. Make sure that the masking tape does not have a shiny surface. Also, mailing labels or colored round labels can be used. These labels will also make identification of the test area easier if it is necessary to do the test again.
Another way to limit the amount of reflected infrared energy is to hold a piece of paper or cardboard between the source of infrared energy and the reflective surface of the object to be tested. Leave this paper or cardboard in position for approximately 30-60 seconds before the object is tested.
The best method to prevent reflected infrared energy is to take a temperature measurement on the opposite side of the object, if possible. This is the side that is away from other sources of infrared energy.
Special Instruction, Form SEHS8149 has complete instructions for use of the 6V6125 Infrared Thermometer (part of the 6V5000 Infrared Thermometer Group).
There have also been reports that some tests have not been accurate because of infrared energy reflected from other objects. This reflected infrared energy, which can be reflected in the same way that light is, can cause a temperature indication that is too high on the object being tested. These reflections can come from or be the result of a shiny surface, electric lights, the sun or a heat source too close to the object to be tested. Other objects that can give a wrong indication are polished (smooth) painted surfaces or shiney metal surfaces such as hydraulic cylinder rods or stainless steel exhaust stacks.
For example, on some marine engines the aftercooler water line can be near the exhaust manifold. If the water line is tested, the infrared energy from the exhaust manifold will increase the temperature indication of the water line.
Several methods can be used to limit this reflected infrared energy. One way is to put masking tape on the area of the object to be tested. Make sure that the masking tape does not have a shiny surface. Also, mailing labels or colored round labels can be used. These labels will also make identification of the test area easier if it is necessary to do the test again.
Another way to limit the amount of reflected infrared energy is to hold a piece of paper or cardboard between the source of infrared energy and the reflective surface of the object to be tested. Leave this paper or cardboard in position for approximately 30-60 seconds before the object is tested.
The best method to prevent reflected infrared energy is to take a temperature measurement on the opposite side of the object, if possible. This is the side that is away from other sources of infrared energy.
Special Instruction, Form SEHS8149 has complete instructions for use of the 6V6125 Infrared Thermometer (part of the 6V5000 Infrared Thermometer Group).
Cat SIS web machinery list:
Parts gasket Caterpillar catalog:
8N3658
GASKET-PLATE
12G, 140B, 140G, 14G, 1673C, 235, 3306, 528, 561D, 571G, 572G, 627B, 637D, 639D, 815, 816, 966C, 977L, D5B, D6D, D7G, G3306
12G, 140B, 140G, 14G, 1673C, 235, 3306, 528, 561D, 571G, 572G, 627B, 637D, 639D, 815, 816, 966C, 977L, D5B, D6D, D7G, G3306
7E0701
GASKET
3606, 3612, G3606, G3606B, G3608, G3612, G3616
3606, 3612, G3606, G3606B, G3608, G3612, G3616
4S7914
GASKET
631C, 641B, 650B, 657, 657B, 666, 769, 772, 834, D343, G3408, G3412, G342C, G343, G353D, G379, G398, G399
631C, 641B, 650B, 657, 657B, 666, 769, 772, 834, D343, G3408, G3412, G342C, G343, G353D, G379, G398, G399
7W5215
GASKET
G3508, G3512, G3516, G3606, G3608, G3612, G3616
G3508, G3512, G3516, G3606, G3608, G3612, G3616
1432878
GASKET
G3606, G3606B, G3608, G3612, G3616
G3606, G3606B, G3608, G3612, G3616
7E1630
GASKET
G3606, G3606B, G3608, G3612, G3616
G3606, G3606B, G3608, G3612, G3616
2196908
GASKET
G3606, G3606B, G3608, G3612, G3616
G3606, G3606B, G3608, G3612, G3616
2197009
GASKET
G3606, G3606B, G3608, G3612, G3616
G3606, G3606B, G3608, G3612, G3616
1440620
GASKET
G3606, G3606B, G3608, G3612, G3616
G3606, G3606B, G3608, G3612, G3616
3700555
GASKET
G3606, G3606B, G3608, G3612, G3616
G3606, G3606B, G3608, G3612, G3616
6L1576
GASKET-CHAMBER
D353C, D379, D379B, D398, G342C, G353D, G379, G398, G399
D353C, D379, D379B, D398, G342C, G353D, G379, G398, G399
3N0962
GASKET
D379B, G399
D379B, G399
1106197
GASKET
3126B, 3412E, 3508B, 3508C, 3512B, 3512C, 3516B, 3516C, 950H, 966H, 972G II, 972H, 980H, C-10, C-12, C-15, C-16, C-9, G3408, G3408C, G3412, G3412C, G3508, G3512, G3516
3126B, 3412E, 3508B, 3508C, 3512B, 3512C, 3516B, 3516C, 950H, 966H, 972G II, 972H, 980H, C-10, C-12, C-15, C-16, C-9, G3408, G3408C, G3412, G3412C, G3508, G3512, G3516
1335251
GASKET
CG137-08, CG137-12, G3408, G3408C, G3412, G3412C, G3508, G3512, G3512E, G3516, G3516C, G3520C
CG137-08, CG137-12, G3408, G3408C, G3412, G3412C, G3508, G3512, G3512E, G3516, G3516C, G3520C
1W9638
GASKET
G3408, G3408B, G3408C, G3412, G3412C
G3408, G3408B, G3408C, G3412, G3412C
4W7992
GASKET
G3412, G3412C, G3508, G3512, G3516, G399
G3412, G3412C, G3508, G3512, G3516, G399
4W9606
GASKET
CG137-08, CG137-12, G3406, G3408, G3408B, G3408C, G3412, G3412C
CG137-08, CG137-12, G3406, G3408, G3408B, G3408C, G3412, G3412C
7W4149
GASKET
CG137-08, CG137-12, G3408C, G3412, G3412C, G3508, G3512, G3516
CG137-08, CG137-12, G3408C, G3412, G3412C, G3508, G3512, G3516
1517725
GASKET
3306B
3306B
2008985
GASKET
3508B, 3512, 3512B, 3516, 3516B, 3516C, G3512E, G3516, G3516B, G3516C, G3516E, G3520C, G3520E, SR4, SR4BHV
3508B, 3512, 3512B, 3516, 3516B, 3516C, G3512E, G3516, G3516B, G3516C, G3516E, G3520C, G3520E, SR4, SR4BHV
1447600
GASKET
3406C, 3516B, HT400, SPF343, SPT343
3406C, 3516B, HT400, SPF343, SPT343
1139543
GASKET
3306B, 3406B, 3406C, 3406E, 3412, 3456, C15, C15 I6, C18, C9, G3406
3306B, 3406B, 3406C, 3406E, 3412, 3456, C15, C15 I6, C18, C9, G3406
1328080
GASKET
3306B
3306B
1328079
GASKET
3306B
3306B