GASKET 1R5337 - Caterpillar



1R5337 GASKET Caterpillar parts
Rating:
81
Alternative (cross code) number:
CA1R5337
1R-5337
1R5337
Caterpillar 1R5337 GASKET
Weight: 0.30 pounds 0 kg.

Buy GASKET 1R5337 Caterpillar genuine, new aftermarket tractor parts with delivery

Compare Prices:

As an associate, we earn commssions on qualifying purchases through the links below
$18.42
 

21 Dec 2023

US: Florida-Parts-Z
1R5337 - Oil PAN Gasket C6.4-320D 2128566 5I7613 fits Caterpillar (CAT)
FIRST PRICE PARTS
$17.67
 

05 Dec 2023

US: Florida-Parts-Z
5I7666 - Gasket 5I7612 1R5337 5I4988 1352342 1352343 1786536 1838230 for Caterp
FIRST PRICE PARTS
$17.67
 

26 May 2022

US: Florida-Parts-Z
5I7666 - Gasket 5I7612 1R5337 5I4988 1352342 1352343 1786536 1838230 for Caterp
FIRST PRICE PARTS
  For full view, you need register


Information:

The Programmable Cycle Timer (PCT) feature allows the operator to program seven independent times, when tasks (called PCT Outputs), will be activated or deactivated automatically during the week. This is useful for exercising gensets, or cases where two or more generators are required to automatically share the duty of supplying a load throughout the week.Using the PCT, each genset can be programmed to start and stop at pre-set times. The PCT is capable of handling a seven day sequence with seven independent starts happening one or more times each week. The timing of these start/stop cycles may be programmed in advance, either locally or via the service tool.For example, if a standby set does not have access to a utility supply to power a trickle charger, the PCT can be set for an hour a week to keep the battery charged.The PCT feature consists of seven independent timers. The set points that are shown below are for "PCT 1". Each timer has the following set points:Programmable Cycle Timer #1, Activation Day of the Week - This set point permits independent selection of each day, Sunday through Saturday, that the timer will activate. All seven days can be selected, if desired.Programmable Cycle Timer 1, Activation Start Time - This set point determines the time of day, in hours and minutes, that the timer will activate.Programmable Cycle Timer 1, Active Time - This set point determines the duration, in hours and minutes, for which the timer will be active. This set point can be set for up to 24 hours.Programmable Cycle Timer 1, Output 1 Activation Configuration - The Programmable Cycle Timer's first output will be activated when this timer is active and will allow the genset to start if in Auto.Programmable Cycle Timer 1, Output 2 Activation Configuration - The Programmable Cycle Timer's second output will be activated when this timer is active. Output 2 can be assigned to a programmable output for connection to an external device. This external device can be used to control a load bank, transfer switch or other device.The PCT has two internal outputs; these should not be confused with the physical outputs of the control. The outputs are connected internally to the control module. In the standard configuration, PCT output 1 is connected to a remote initiate command. Output 2 is customer configurable via a discrete output. This allows the operator to configure a timed relay, for external connectivity.Note: Note: The outputs of all seven timers are tied together in an "OR" fashion. This means that if any one, or more, timer is activated, then any output will activate (depending on programming).
Illustration 1 g02275056The status of each output is indicated by a "1", "0", or "-" in the "PROG CYCLE" column under 1 through 7. Refer to Illustration 1.The following is an explanation of the outputs as shown in Illustration 1.
A number one (1) means that this PCT is driving that output to be true
A number zero (0) means that this PCT is NOT

Parts gasket Caterpillar catalog:

1R5334 GASKET
Caterpillar