4765589 GASKET Caterpillar parts
Rating:
Alternative (cross code) number:
CA4765589
476-5589
4765589
CA4765589
476-5589
4765589
Information:
Continuity Check of the Glow Plugs
Table 1
Required Tools
Part Number Part Name Qty
6V-7070 Digital Multimeter 1 The following test will check the continuity of the glow plugs.
Disconnect the power supply and the bus bar.
Set the 6V-7070 Digital Multimeter to check continuity (resistance). Turn the audible signal on the digital multimeter ON.
Place one probe on the connection for the glow plug and the other probe to a suitable ground. The Digital Multimeter should make an audible sound. Replace the glow plug if there is no continuity.
Check the continuity on all the glow plugs. Checking The Operation of The Glow Plug
Table 2
Required Tools
Part Number Part Name Qty
225-8266 Ammeter 1
6V-7070 Digital Multimeter 1 The following test will check the operation of the glow plugs.
Disconnect the power supply and the bus bar.
Connect the power supply to only one glow plug.
Place the 225-8266 Ammeter on the power supply wire.
Connect the 6V-7070 Digital Multimeter to the terminal on the glow plug and to a suitable ground.
Turn the switch to the ON position in order to activate the glow plugs.
Table 3
12 Volt System
Amp Time (sec)
30 Initial
21 4
14 8
10 20
9 60
Table 4
24 Volt System
Amp Time (sec)
12 Initial
8.5 8
7 20
6 60
Check the reading on all of the glow plugs.
If there is no reading on the ammeter check the electrical connections. If the readings on the ammeter are low replace the glow plugs. If there is still no reading replace the glow plugs.
Table 1
Required Tools
Part Number Part Name Qty
6V-7070 Digital Multimeter 1 The following test will check the continuity of the glow plugs.
Disconnect the power supply and the bus bar.
Set the 6V-7070 Digital Multimeter to check continuity (resistance). Turn the audible signal on the digital multimeter ON.
Place one probe on the connection for the glow plug and the other probe to a suitable ground. The Digital Multimeter should make an audible sound. Replace the glow plug if there is no continuity.
Check the continuity on all the glow plugs. Checking The Operation of The Glow Plug
Table 2
Required Tools
Part Number Part Name Qty
225-8266 Ammeter 1
6V-7070 Digital Multimeter 1 The following test will check the operation of the glow plugs.
Disconnect the power supply and the bus bar.
Connect the power supply to only one glow plug.
Place the 225-8266 Ammeter on the power supply wire.
Connect the 6V-7070 Digital Multimeter to the terminal on the glow plug and to a suitable ground.
Turn the switch to the ON position in order to activate the glow plugs.
Table 3
12 Volt System
Amp Time (sec)
30 Initial
21 4
14 8
10 20
9 60
Table 4
24 Volt System
Amp Time (sec)
12 Initial
8.5 8
7 20
6 60
Check the reading on all of the glow plugs.
If there is no reading on the ammeter check the electrical connections. If the readings on the ammeter are low replace the glow plugs. If there is still no reading replace the glow plugs.
Caterpillar parts catalog:
Parts gasket Caterpillar catalog:
4755823
GASKET
Caterpillar
Caterpillar
4755796
GASKET
Caterpillar
Caterpillar
4729127
GASKET
Caterpillar
Caterpillar
2Y4976
GASKET
Caterpillar
Caterpillar
9W1604
GASKET
Caterpillar
Caterpillar
4F0501
GASKET
Caterpillar
Caterpillar
5191103
GASKET
Caterpillar
Caterpillar
5191094
GASKET
Caterpillar
Caterpillar
5182006
GASKET
Caterpillar
Caterpillar
5181948
GASKET
Caterpillar
Caterpillar
5181856
GASKET-COVER
Caterpillar
Caterpillar
4780588
GASKET
Caterpillar
Caterpillar