Schematic of the Diverter SolenoidThis diagnostic code is recorded when the ECM reads the current of the solenoid as being above normal.The possible causes are listed:
A wire is shorted to ground.
The solenoid has failed.
The ECM has failed. This is unlikely.System Response:The machine response is listed:
When the autocarry function is active, the hydraulic oil may overheat when the machine is in the carry segment.
The expected operation of the autocarry function is not correct. Note: Ensure that CID 1709 FMI 06 for the solenoid is active. Note: The following procedure can create numerous related diagnostic codes. When all harnesses are reconnected, the related diagnostic codes will be shown as being not active. Clear all related diagnostic codes after this procedure is completed.Test Step 1. CHECK THE SOLENOID.
Turn the disconnect switch and the key start switch to the ON position. Do not start the engine.
Disconnect the machine harness from the solenoid.
At the connector for the sensor, install a jumper wire from contact 1 (wire H735-GY) to contact 2 (wire H806-OR).
Observe the status of the diagnostic code.Expected Result:The diagnostic code is active. Then, the diagnostic code is not active as the jumper wire is installed and removed. Results:
YES - The circuit is correct. The solenoid has failed.Repair: Repeat this test "CHECK THE SOLENOID" in order to verify that the solenoid has failed. Replace the solenoid.STOP
NO - The diagnostic code remains active. Proceed to test step 2.Test Step 2. CHECK THE SOLENOID CIRCUIT FOR A SHORT TO GROUND.
The machine harness remains disconnected from the solenoid.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the J1 and J2 machine harness connector from the ECM.
At the J2 machine harness connector, measure the resistance from the solenoid contact J2-64 (wire H735-GY) to all possible sources of ground. The possible sources of ground are listed: J1-9 (wire J764-BR), J2-2 (wire 210-BK), J2-12 (wire H805-BR), J2-13 (wire H804-GN), J2-22 (wire 210-BK), J2-46 (wire 210-BK), J2-49 (wire H802-GY), J2-52 (wireH801-PU), J2-56 (wire 210-BK), J2-59 (wire H803-BU), J2-69 (wire 210-BK) and frame ground.Expected Result:Each resistance measurement should be greater than 5000 ohms.Results:
YES - Each measurement is greater than 5000 ohms. The machine harness is correct. Proceed to test step 3.
NO - One or more measurements is not correct. There is an short in the machine harness.Repair: The short is between the wire for the solenoid signal and the circuit with the low resistance measurement. Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK IF THE DIAGNOSTIC CODE REMAINS.
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Clear all inactive diagnostic codes.
Operate the machine.
Stop the machine and place the parking brake switch in the ON position.
Check if the diagnostic code for the solenoid is active.Expected Result:The diagnostic code is no longer active. Results:
YES - The diagnostic code is no longer active. The diagnostic code does not exist at this time. The initial diagnostic code was probably caused
Parts gasket Caterpillar catalog:
5370200
GASKET
Caterpillar
Caterpillar
5370194
GASKET
Caterpillar
Caterpillar
5370167
GASKET
Caterpillar
Caterpillar
5370164
GASKET
Caterpillar
Caterpillar
5370163
GASKET
Caterpillar
Caterpillar
5370160
GASKET
Caterpillar
Caterpillar
5370241
GASKET
Caterpillar
Caterpillar
5370234
GASKET
Caterpillar
Caterpillar
5370233
GASKET
Caterpillar
Caterpillar
5370232
GASKET
Caterpillar
Caterpillar
5370231
GASKET
Caterpillar
Caterpillar
5370230
GASKET
Caterpillar
Caterpillar