6V1343 GASKET KT-WP Caterpillar parts
Rating:
Alternative (cross code) number:
CA6V1343
6V-1343
6V1343
CA6V1343
6V-1343
6V1343
Weight: 0.23 pounds 0 kg.
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$13.98
12 Jul 2022
0.39[0.18] Pounds
US: ProperBuy
6V1343 Group-Water Pump O/H Fits Caterpillar 8S7057 816 815 120 12F 140 14E 561C
CTP Warranty
CTP Warranty
Information:
Lead Numbering
Each coil lead is marked according to the following diagram.Numbering is clockwise from the top and from the outside in. Terminal TO is the neutral lead on all high voltage connections. On low voltage connections TO is connected with T4, T5, and T6 to form the neutral terminal. The standard generator diagram and the terminal connections are on the nameplate of each generator. Neutral Connections
Single Units
Three Wire: In a three phase, three wire system, the generator should normally be grounded according to local wiring codes. In some cases, however, it is undesirable to ground the neutral wire. For example, on boats a grounded neutral may increase the problem of electrolysis. In applications where definite measures are taken to prevent grounds to the load leads, an ungrounded neutral can be used. Be sure to check your local wiring codes.Four Wire: In a three phase, four wire system, the neutral wire should be grounded according to local wiring codes. For only single unit operation, there should never be a need for a disconnect switch, or device, in the neutral line.Multiple Units
Operation of multiple generators in parallel, having all neutrals grounded, may result in current circulating through the neutral connections. To eliminate the possibility of circulating currents, ground the neutral of only one generator. If multiple generators are alternated on line, a single pole single throw knife switch should be installed in the neutral ground circuit of each generator, so all but one neutral ground circuit can be opened. Be sure one neutral ground circuit is closed.Voltage Connections
Three Phase
The connections for both high and low voltage are given in the following diagrams.
TYPICAL LOW VOLTAGE CONNECTIONThe terminals must be connected securely and insulated with a good quality electrical tape.
TYPICAL HIGH VOLTAGE CONNECTIONSingle Phase Current From A Three-Phase Generator
Three phase and single phase current can be taken simultaneously from a generator connected for three phase service. Connecting the load to any two of the three phase leads will provide single phase voltage at the same voltage as three phase power. Connecting the load to any phase lead and to neutral will produce voltage at 58% of the three phase voltage. DO NOT exceed the nameplate current rating for any one phase.Single phase power taken from a three phase source can be a problem unless the single phase loading is equally distributed.
Each coil lead is marked according to the following diagram.Numbering is clockwise from the top and from the outside in. Terminal TO is the neutral lead on all high voltage connections. On low voltage connections TO is connected with T4, T5, and T6 to form the neutral terminal. The standard generator diagram and the terminal connections are on the nameplate of each generator. Neutral Connections
Single Units
Three Wire: In a three phase, three wire system, the generator should normally be grounded according to local wiring codes. In some cases, however, it is undesirable to ground the neutral wire. For example, on boats a grounded neutral may increase the problem of electrolysis. In applications where definite measures are taken to prevent grounds to the load leads, an ungrounded neutral can be used. Be sure to check your local wiring codes.Four Wire: In a three phase, four wire system, the neutral wire should be grounded according to local wiring codes. For only single unit operation, there should never be a need for a disconnect switch, or device, in the neutral line.Multiple Units
Operation of multiple generators in parallel, having all neutrals grounded, may result in current circulating through the neutral connections. To eliminate the possibility of circulating currents, ground the neutral of only one generator. If multiple generators are alternated on line, a single pole single throw knife switch should be installed in the neutral ground circuit of each generator, so all but one neutral ground circuit can be opened. Be sure one neutral ground circuit is closed.Voltage Connections
Three Phase
The connections for both high and low voltage are given in the following diagrams.
TYPICAL LOW VOLTAGE CONNECTIONThe terminals must be connected securely and insulated with a good quality electrical tape.
TYPICAL HIGH VOLTAGE CONNECTIONSingle Phase Current From A Three-Phase Generator
Three phase and single phase current can be taken simultaneously from a generator connected for three phase service. Connecting the load to any two of the three phase leads will provide single phase voltage at the same voltage as three phase power. Connecting the load to any phase lead and to neutral will produce voltage at 58% of the three phase voltage. DO NOT exceed the nameplate current rating for any one phase.Single phase power taken from a three phase source can be a problem unless the single phase loading is equally distributed.
Parts gasket Caterpillar catalog:
6V1342
GASKET KIT
Caterpillar
Caterpillar
6V1341
GASKET KIT
Caterpillar
Caterpillar
6V1340
GASKET KIT
Caterpillar
Caterpillar
6V1339
GASKET KIT
Caterpillar
Caterpillar
6V1334
GASKET KIT FRT
Caterpillar
Caterpillar
6V1312
GASKET KIT
Caterpillar
Caterpillar
6V1398
GASKET KT-
Caterpillar
Caterpillar
6V1397
GASKET KIT OIL
Caterpillar
Caterpillar
6V1396
GASKET KIT V
Caterpillar
Caterpillar
6V1395
GASKET KIT V
Caterpillar
Caterpillar
6V1346
GASKET KIT
Caterpillar
Caterpillar
6V1344
GASKET KT-
Caterpillar
Caterpillar