9L9164 GASKET Caterpillar parts
1140, 1160, 225, 3160, 3204, 3208, 613B, 910, 931B, 943, D3
Rating:
Alternative (cross code) number:
CA9L9164
9L-9164
9L9164
CA9L9164
9L-9164
9L9164
Weight: 0.50 pounds 0 kg.
COMPACT WHEEL LOADER, WHEEL TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$54.15
04 Jan 2024
US: FinditParts Inc
9L9164 - HEAD GASKET 3208 fits Caterpillar (CAT)
BLUMAQ 9L9164 - HEAD GASKET 3208 fits Caterpillar (CAT)
BLUMAQ 9L9164 - HEAD GASKET 3208 fits Caterpillar (CAT)
Compatible equipment models: 9L9164:
Information:
Attach a "Do Not Operate" warning tag to the key switch before the system is serviced or repaired. If a "Do Not Operate" warning tag is not available, use a similar warning tag. If the tag cannot be attached to the key switch, attach the warning tag to the controls. The warning tags are available from the Caterpillar dealer. Attach the warning tags to the system and to each operator control station.
Illustration 1 g00104545
Do not allow unauthorized personnel on the system, or around the system when the system is being serviced.Speeds, temperatures, and load are the best indicators of performance. Rely on instrumentation. Record all readings. Compare these readings with previous readings in order to detect developing abnormalities.
Wear a hard hat, protective glasses, and other protective equipment, as required.
Do not wear loose clothing or jewelry that can snag on controls or on other parts of the system.
Ensure that all protective guards and all covers are secured in place on the system.
Never put maintenance fluids into glass containers. Glass containers can break.
Use all cleaning solutions with care.
Report all necessary repairs.Unless other instructions are provided, perform the maintenance under the following conditions:
The system is stopped and the system is disconnected from power. Ensure that the system cannot be powered or ensure that power cannot be applied to the system.
Do not attempt any repairs that are not understood. Use the proper tools. Replace any equipment that is damaged or repair the equipment.
Remove all tools, electrical cords, and any other loose items from the system before starting the system.Safety Precautions
Read this manual thoroughly. Pay special attention to the sections that apply to you before working with this system. Retain this section for use by installing personnel.While the doors are closed, only normal safety precautions are necessary under typical operation. The area around the system should be kept free from puddles of water, excess moisture, or debris.Special safety precautions are required for procedures that involve the handling, the installation, and the maintenance of the system. Observe all safety precautions in this manual before the performance of all maintenance procedures and during the performance of all maintenance procedures.This equipment contains several circuits that are energized with high voltage. Only test equipment that has been designated for troubleshooting, such as oscilloscopes, should be used. Always check with an AC voltmeter and a DC voltmeter in order to ensure safety before making contact or using tools. Even when the power is turned Off, high voltages may exist at the capacitor banks.ONLY qualified service personnel should perform maintenance on the UPS. When you are performing maintenance with any part of the equipment under power, service personnel and test equipment should be standing on rubber mats. The service personnel should wear insulating shoes for isolation from direct contact with the floor (earth ground).Personnel should never work alone unless all power is removed from the equipment. A second person should be standing close in case an accident should occur.
Illustration 1 g00104545
Do not allow unauthorized personnel on the system, or around the system when the system is being serviced.Speeds, temperatures, and load are the best indicators of performance. Rely on instrumentation. Record all readings. Compare these readings with previous readings in order to detect developing abnormalities.
Wear a hard hat, protective glasses, and other protective equipment, as required.
Do not wear loose clothing or jewelry that can snag on controls or on other parts of the system.
Ensure that all protective guards and all covers are secured in place on the system.
Never put maintenance fluids into glass containers. Glass containers can break.
Use all cleaning solutions with care.
Report all necessary repairs.Unless other instructions are provided, perform the maintenance under the following conditions:
The system is stopped and the system is disconnected from power. Ensure that the system cannot be powered or ensure that power cannot be applied to the system.
Do not attempt any repairs that are not understood. Use the proper tools. Replace any equipment that is damaged or repair the equipment.
Remove all tools, electrical cords, and any other loose items from the system before starting the system.Safety Precautions
Read this manual thoroughly. Pay special attention to the sections that apply to you before working with this system. Retain this section for use by installing personnel.While the doors are closed, only normal safety precautions are necessary under typical operation. The area around the system should be kept free from puddles of water, excess moisture, or debris.Special safety precautions are required for procedures that involve the handling, the installation, and the maintenance of the system. Observe all safety precautions in this manual before the performance of all maintenance procedures and during the performance of all maintenance procedures.This equipment contains several circuits that are energized with high voltage. Only test equipment that has been designated for troubleshooting, such as oscilloscopes, should be used. Always check with an AC voltmeter and a DC voltmeter in order to ensure safety before making contact or using tools. Even when the power is turned Off, high voltages may exist at the capacitor banks.ONLY qualified service personnel should perform maintenance on the UPS. When you are performing maintenance with any part of the equipment under power, service personnel and test equipment should be standing on rubber mats. The service personnel should wear insulating shoes for isolation from direct contact with the floor (earth ground).Personnel should never work alone unless all power is removed from the equipment. A second person should be standing close in case an accident should occur.
Cat SIS web machinery list:
Parts gasket Caterpillar catalog:
9P5572
GASKET
D3, D3C
D3, D3C
9P5571
GASKET
910, 931, 931B, 931C
910, 931, 931B, 931C
1W1109
GASKET
931B
931B
1W1110
GASKET
508, 931B
508, 931B
4B8994
GASKET
140B, 14E, 619, 910, 963, 966D, 966F, 973, 980C, D6H
140B, 14E, 619, 910, 963, 966D, 966F, 973, 980C, D6H
1W4334
GASKET-GEAR COVER
508, 931B
508, 931B
3L0625
GASKET
613, 613B, 613C, 613C II, D250D
613, 613B, 613C, 613C II, D250D
1T0904
GASKET
613, 613B, 613C, 613C II, D250D
613, 613B, 613C, 613C II, D250D
5H3703
GASKET
120, 120B, 12E, 12F, 140, 140B, 14E, 16, 518, 528, 528B, 530B, 613, 630A, 631C, 657, 657B, 910, 920, 930, 950, FB518, IT12
120, 120B, 12E, 12F, 140, 140B, 14E, 16, 518, 528, 528B, 530B, 613, 630A, 631C, 657, 657B, 910, 920, 930, 950, FB518, IT12
7S7019
GASKET
518, 518C, 528, 528B, 530B, 613, 613B, 920, 930, FB518
518, 518C, 528, 528B, 530B, 613, 613B, 920, 930, FB518
1K6519
GASKET
140B, 14E, 518, 528, 528B, 530B, 613B, 910, 920, 930, 950
140B, 14E, 518, 528, 528B, 530B, 613B, 910, 920, 930, 950
1S9865
GASKET
613, 613B
613, 613B
3N2832
GASKET
1673C, 3304, 3306, D6C
1673C, 3304, 3306, D6C
4N4431
GASKET
1673C, 215, 225, 235, 3304, 3306, 518, 528, 627B, 637D, 920, 930, 950, 966C, 977K, D4D, D5, D6C, D6D, D7F, D7G
1673C, 215, 225, 235, 3304, 3306, 518, 528, 627B, 637D, 920, 930, 950, 966C, 977K, D4D, D5, D6C, D6D, D7F, D7G
4N0403
GASKET
120G, 1673C, 225, 3304, 3306, 518, 920, 930, 941, 950, 951B, 955K, 966C, D4D, D5, D6C, D7G
120G, 1673C, 225, 3304, 3306, 518, 920, 930, 941, 950, 951B, 955K, 966C, D4D, D5, D6C, D7G
1P6442
GASKET (.140 IN. TH.)
D342, D8H, D8K
D342, D8H, D8K
1P6441
GASKET (.156 IN. TH.)
D342, D8H, D8K
D342, D8H, D8K
6N1330
GASKET
D342, D8H
D342, D8H
2N7464
GASKET
776, 777, D10, D346, D348, D349
776, 777, D10, D346, D348, D349
5H4457
GASKET
594, D353C, D9E, D9G, D9H, G353D
594, D353C, D9E, D9G, D9H, G353D
5H4470
GASKET
594, D353C, D9E, D9G, D9H
594, D353C, D9E, D9G, D9H
4N5196
GASKET
D353C, D9G, D9H
D353C, D9G, D9H
4N4125
GASKET
16G, 245, 3406, 621B, 824C, 826C
16G, 245, 3406, 621B, 824C, 826C
5B6687
GASKET
D342, D353C, D364, D375D, G342C, G353D
D342, D353C, D364, D375D, G342C, G353D