Removal Procedure
Reference: Special Instruction, "Visual Service Procedures - Colors and Symbols" , M0066576.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Illustration 1 g06278589
Recover the refrigerant. Refer to Service Manual, SENR5664, "All Products Air Conditioning and Heating Systems with R134a for All Caterpillar Machines" for the recovery and charging procedures. Refer to Special Publication, NENG2500, "Air Conditioning Tools" for the correct tools.
Illustration 2 g06278615
Illustration 3 g06278616Installation Procedure
Install refrigerant condenser in the reverse order of removal.
Illustration 4 g06278617
Illustration 5 g06278619
Reference: Special Instruction, "Visual Service Procedures - Colors and Symbols" , M0066576.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Illustration 1 g06278589
Recover the refrigerant. Refer to Service Manual, SENR5664, "All Products Air Conditioning and Heating Systems with R134a for All Caterpillar Machines" for the recovery and charging procedures. Refer to Special Publication, NENG2500, "Air Conditioning Tools" for the correct tools.
Illustration 2 g06278615
Illustration 3 g06278616Installation Procedure
Install refrigerant condenser in the reverse order of removal.
Illustration 4 g06278617
Illustration 5 g06278619
Caterpillar parts catalog:
Parts gauge Caterpillar catalog:
2496706
GAUGE-OIL LEVEL (DIPSTICK)
725C, C-9, C9
725C, C-9, C9
9Y9592
GAUGE-MODULE
3606, 3608, 3612, 3616
3606, 3608, 3612, 3616
9Y9591
GAUGE-ELECTRONIC
3606, 3608, 3612, 3616
3606, 3608, 3612, 3616
7E0448
GAUGE-ELECTRONIC
3606, 3608, 3612, 3616
3606, 3608, 3612, 3616
8T0862
GAUGE-PRESSURE
3606, 3612, 3616
3606, 3612, 3616
1923223
GAUGE GP-CRANKCASE PRESSURE
3608, 3612, 3616
3608, 3612, 3616