7K0673 GAUGE ASSEM. Caterpillar parts
955K, 955L
Rating:
Alternative (cross code) number:
CA7K0673
7K-0673
7K0673
CA7K0673
7K-0673
7K0673
Weight: 0.50 pounds 0 kg.
TRACK LOADER,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
CTP 7K0673 Gage Oil Lever Assembly
CTP Sold in each || Highly Efficient || Easy in-and-out fit
CTP Sold in each || Highly Efficient || Easy in-and-out fit
CTP 7K0673 Gage Oil Lever Assembly
CTP Sold in each || Highly Efficient || Easy in-and-out fit
CTP Sold in each || Highly Efficient || Easy in-and-out fit
Information:
Instrument Panel Switches
Illustration 1 g00310265
Instrument Panel Switches (1) Starting Aid Switch (SAS) (optional). (2) Governor Switch (GS) (optional) or Speed Potentiometer (SP) (optional). (3) Panel Light Switch (PLS) (optional). (4) Engine Control Switch (ECS). (5) Voltage Adjust Rheostat (VAR). (6) Emergency Stop Push Button (ESPB). The engine control switch (ECS) (4) determines the status of the control panel. In the AUTO position (3 o'clock), the GSC allows the operator to remotely control and monitor the generator set with a Customer Communication Module. See Systems Operation, "Customer Communication Module". Also, the GSC allows the engine to start whenever the remote initiating contact (IC) is closed. The engine also shuts down after the initiate contacts open. A cooldown period is programmable (setpoint P19) in order to give a 0 to 30 minute cooldown period before the engine shuts down. The cooldown period is factory set at five minutes. In the MANUAL START position (6 o'clock), the engine starts and runs as long as the ECS is in this position. In the COOLDOWN/STOP position (9 o'clock), the fuel solenoid shuts down the engine after the cooldown period. In the OFF/RESET position (12 o'clock), the engine shuts down immediately and any fault indicators are reset except the emergency stop. If the red emergency stop push button (ESPB) (6) is pressed, the fuel is shut off. In order to restart the engine, follow these steps: Turn the ESPB (6) clockwise until the push button releases. Turn the ECS to OFF/RESET and then turn the ECS to MANUAL START.The voltage adjust rheostat (VAR) (5) is used to adjust the generator voltage to the desired level.The optional governor switch (GS) (2) is used to change the engine speed when the governor has a speed adjust motor. If an electronic governor is used, a speed adjust potentiometer (SP) is mounted in this location. The optional panel light switch (PLS) (3) turns the panel lamps ON and OFF. The optional starting aid switch (SAS) (1) is present only on required gensets. Two types of starting aid systems exist. Manual - This type is used for metered shot starting aid systems. Automatic - This type is used for continuous flow starting aid systems (3500 engines only).On manual starting aid types, when SAS (1) is placed and held in the ON position, the metered shot starting aid system is activated. A specific amount of ether is metered into a holding chamber. When SAS (1) is released, a solenoid allows ether to flow to the engine. The metered shot starting aid system deactivates when any of the following events occur:
The contacts of the crank termination relay (CTR) open at an engine speed of approximately 400 rpm.
The engine coolant temperature is sufficient to open the start aid temperature switch (SATS).
The SAS (1) is released to the OFF position.
Crank the engine before activating (keep SAS in OFF position) the metered shot start aid system. Damage to the engine is possible by activating the system when the engine is not turning.
On automatic starting aid
Illustration 1 g00310265
Instrument Panel Switches (1) Starting Aid Switch (SAS) (optional). (2) Governor Switch (GS) (optional) or Speed Potentiometer (SP) (optional). (3) Panel Light Switch (PLS) (optional). (4) Engine Control Switch (ECS). (5) Voltage Adjust Rheostat (VAR). (6) Emergency Stop Push Button (ESPB). The engine control switch (ECS) (4) determines the status of the control panel. In the AUTO position (3 o'clock), the GSC allows the operator to remotely control and monitor the generator set with a Customer Communication Module. See Systems Operation, "Customer Communication Module". Also, the GSC allows the engine to start whenever the remote initiating contact (IC) is closed. The engine also shuts down after the initiate contacts open. A cooldown period is programmable (setpoint P19) in order to give a 0 to 30 minute cooldown period before the engine shuts down. The cooldown period is factory set at five minutes. In the MANUAL START position (6 o'clock), the engine starts and runs as long as the ECS is in this position. In the COOLDOWN/STOP position (9 o'clock), the fuel solenoid shuts down the engine after the cooldown period. In the OFF/RESET position (12 o'clock), the engine shuts down immediately and any fault indicators are reset except the emergency stop. If the red emergency stop push button (ESPB) (6) is pressed, the fuel is shut off. In order to restart the engine, follow these steps: Turn the ESPB (6) clockwise until the push button releases. Turn the ECS to OFF/RESET and then turn the ECS to MANUAL START.The voltage adjust rheostat (VAR) (5) is used to adjust the generator voltage to the desired level.The optional governor switch (GS) (2) is used to change the engine speed when the governor has a speed adjust motor. If an electronic governor is used, a speed adjust potentiometer (SP) is mounted in this location. The optional panel light switch (PLS) (3) turns the panel lamps ON and OFF. The optional starting aid switch (SAS) (1) is present only on required gensets. Two types of starting aid systems exist. Manual - This type is used for metered shot starting aid systems. Automatic - This type is used for continuous flow starting aid systems (3500 engines only).On manual starting aid types, when SAS (1) is placed and held in the ON position, the metered shot starting aid system is activated. A specific amount of ether is metered into a holding chamber. When SAS (1) is released, a solenoid allows ether to flow to the engine. The metered shot starting aid system deactivates when any of the following events occur:
The contacts of the crank termination relay (CTR) open at an engine speed of approximately 400 rpm.
The engine coolant temperature is sufficient to open the start aid temperature switch (SATS).
The SAS (1) is released to the OFF position.
Crank the engine before activating (keep SAS in OFF position) the metered shot start aid system. Damage to the engine is possible by activating the system when the engine is not turning.
On automatic starting aid
Caterpillar parts catalog:
Parts gauge Caterpillar catalog:
2P6494
GAUGE GP-OIL LEVEL (DIPSTICK)
941, 950, 951B, 955K, 955L, D4D
941, 950, 951B, 955K, 955L, D4D
8M7892
GAUGE AS-AMMETER
120, 120B, 120G, 12G, 130G, 140B, 140G, 1676, 16G, 215, 225, 235, 245, 3126, 3160, 3176B, 3208, 3304, 3304B, 3306, 3306B, 3306C, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412...
120, 120B, 120G, 12G, 130G, 140B, 140G, 1676, 16G, 215, 225, 235, 245, 3126, 3160, 3176B, 3208, 3304, 3304B, 3306, 3306B, 3306C, 3406, 3406B, 3406C, 3406E, 3408, 3408B, 3408C, 3408E, 3412, 3412C, 3412...
1V0943
GAUGE AND DASH GROUP
955K, 955L
955K, 955L
1F7307
GAUGE AS-AMMETER
225, 235, 3208, 3306, 3406, 3406B, 3408, 3412, 3508, 3512, 3516, 561B, 561C, 571G, 572G, 583H, 583K, 594, 594H, 613, 613B, 941, 951B, 955H, 955K, 955L, 977H, 977K, 983, D315, D320A, D326F, D330A, D333...
225, 235, 3208, 3306, 3406, 3406B, 3408, 3412, 3508, 3512, 3516, 561B, 561C, 571G, 572G, 583H, 583K, 594, 594H, 613, 613B, 941, 951B, 955H, 955K, 955L, 977H, 977K, 983, D315, D320A, D326F, D330A, D333...
1B9660
GAUGE (VALVE CLEARANCE)
12E, 16, 561B, 583H, 594, 631C, 651, 657, 824, 834, 941, 950, 955C, 955H, 955K, 966C, 977D, 977H, 980, 988, D315, D326F, D337, D337F, D342, D353C, D364, D375D, D397D, D4D, D5, D6C, D8H, D9E, D9G
12E, 16, 561B, 583H, 594, 631C, 651, 657, 824, 834, 941, 950, 955C, 955H, 955K, 966C, 977D, 977H, 980, 988, D315, D326F, D337, D337F, D342, D353C, D364, D375D, D397D, D4D, D5, D6C, D8H, D9E, D9G
5S2898
GAUGE ASSEM.
941, 951B, 955K, 955L
941, 951B, 955K, 955L
7K0672
GAUGE ASSEM.
955K, 955L
955K, 955L
4N2234
GAUGE (Fuel Pressure)
12G, 130G, 140G, 627B, 814, 815, 920, 930, 941, 950, 955K, 955L, 966C, D4D
12G, 130G, 140G, 627B, 814, 815, 920, 930, 941, 950, 955K, 955L, 966C, D4D
2S1989
GAUGE (Water Pressure)
571G, 572G, 583K, 594, 594H, 955K, 955L, 977H, D7F, D7G, D8H, D8K, D9G, D9H
571G, 572G, 583K, 594, 594H, 955K, 955L, 977H, D7F, D7G, D8H, D8K, D9G, D9H
5H4578
GAUGE
583H, 955H, 977H, D8H, D9E
583H, 955H, 977H, D8H, D9E
8M4888
GAUGE
651, 657, 955H, 977H, D8H, D9G
651, 657, 955H, 977H, D8H, D9G
2S1989
GAUGE (Water Pressure)
571G, 572G, 583K, 594, 594H, 955K, 955L, 977H, D7F, D7G, D8H, D8K, D9G, D9H
571G, 572G, 583K, 594, 594H, 955K, 955L, 977H, D7F, D7G, D8H, D8K, D9G, D9H
7S3139
GAUGE ASSEM.
951B
951B
4N0234
GAUGE ASSEM.
931B, D3
931B, D3
9S6518
GAUGE ASSEM.
D8H, D8K
D8H, D8K