3P4283 GEAR (57 teeth) Caterpillar parts
54
Rating:
Alternative (cross code) number:
CA3P4283
3P-4283
3P4283
CA3P4283
3P-4283
3P4283
Weight: 17 pounds 7 kg.
WINCH,
Compatible equipment models: 3P4283:
Information:
Illustration 7 g03515942
Single-phase, two-wire, L2-L3, zig-zag configuration
Transformer Connections
In order to monitor the generator output voltages greater than 600V, potential transformers (PTs) must be used.Note: The EMCP 4 must be programmed when connecting external PTs. Reference: Systems Operation, "Setpoint Programming" and Testing and Adjusting, "Electronic Control Module (Generator Set) - Configure".Note: The wye configuration of external PTs is preferred for 4-wire wye generators because of the greater accuracy when loads are unbalanced. With the open delta configuration, some power parameters cannot be determined. These parameters are real power phase A, B, C, and power factor phase A, B, C. For maximum accuracy, the open delta configuration of external PTs should be used only for 3-wire delta generators.
Illustration 8 g02286873
Four-wire Wye (Star) configuration
Illustration 8 is a typical example of a Wye configuration of an external potential transformer for the four wire Wye generator.This configuration allows the accurate measurement of all power parameters by the EMCP 4 including when the loads are unbalanced and neutral current is present. All power parameters are shown on the display of the EMCP 4. The EMCP 4 configuration parameter " Generator Connection Configuration" should be set to WYE (or STAR).
Illustration 9 g02286876
Three-phase, three-wire, delta configuration
Open delta configuration of external potential transformers on the 3-wire delta generatorThis configuration allows the accurate measurement of power parameters by the EMCP 4 including when the loads are unbalanced and circulating current is present. The real power phase A, B, and C cannot be determined. The power factor phase A, B, and C cannot be determined. The phases are not shown on the EMCP 4 display. The EMCP 4 configuration parameter "Generator Connection Configuration" should be set to DELTA (3 WIRE).
Illustration 10 g02286877
Three-phase, four-wire, delta configuration
The three phase four-wire is also referred to as the open delta configuration for external potential transformers on the 4-wire wye generator.The three phase four wire configuration results in less accurate measurement of all power parameters by the EMCP 4. Less accurate measurement occurs when the loads are unbalanced and neutral current is present. Real power phase A, B, C and power factor phase A, B, C cannot be determined and are not shown on the EMCP 4 display. The EMCP 4 configuration parameter "Generator Connection Configuration" should be set to DELTA (3 WIRE).On 4-wire wye generators, three separate PTs are required for accurate power metering unless the loads are completely and continually balanced. Even if the loads are balanced, some power parameters cannot be determined. Real power phase A, B, C, and power factor phase A, B, C are not shown on the EMCP 4 display.On 3-wire delta generators, two PTs allow maximum accuracy for all load conditions. Real power phase A, B, C and power factor phase A, B, C cannot be determined and are not shown on the EMCP 4 display.
Table 1
Transformer Connections
Parameter Star 3-WIRE DELTA 4-WIRE DELTA 2-WIRE 1-PHASE 3-WIRE 1-PHASE
Generator Freq OK OK OK OK OK
VL-L AVG OK OK OK OK OK
VA-B OK OK OK OK OK
VB-C OK OK OK Invalid Invalid
VC-A OK OK
Caterpillar parts catalog:
Parts gear Caterpillar catalog:
3P4579
GEAR (18 teeth)
528, 54
528, 54
3P4289
GEAR (57 teeth)
528, 54
528, 54
8S5052
GEAR (27 teeth)
D9G, D9H
D9G, D9H
7M1212
GEAR ASSEM. (57 teeth)
D8H, D9G, D9H
D8H, D9G, D9H
2V6584
GEAR (34 teeth)
955K, 955L
955K, 955L
2P6287
GEAR (24 teeth)
D5, D5B
D5, D5B
1K3421
GEAR AND SHAFT ASSEM. (23 teeth)
561B, 561C, 561D
561B, 561C, 561D
6K2907
GEAR (29 TEETH)
D4D, D4E
D4D, D4E
6K2904
GEAR
D4D, D4E
D4D, D4E
6K2942
GEAR
D4D, D4E
D4D, D4E