4W9986 GEAR-FP DRIVE Caterpillar parts
Rating:
Alternative (cross code) number:
CA4W9986
4W-9986
4W9986
CA4W9986
4W-9986
4W9986
Weight: 11 pounds 5 kg.
Information:
Illustration 3 g01015404
Connect Tool (B) to tee (4).
Illustration 4 g01015407
(D) 152-2023 Nitrogen Charging Fitting Gp
Connect Tool (C) to Tool (D).
Illustration 5 g01015408
Connect Tool (B) to Tool (C).
Release the pressure from the service brake system. Refer to "Pressure Test".
Illustration 6 g03531780
(15) Rear service brake accumulator
(16) Front service brake accumulator
(29) Transmission ECM
(T3) Front service brake pressure test port
(T4) Rear service brake pressure test port
Illustration 7 g03510782
(T3) Front service brake pressure test port
(T4) Rear service brake pressure test port
(15) Rear brake accumulator
(16) Front brake accumulator
Illustration 8 g06036412
Brake charge control solenoid (7).
(7) Brake charge control solenoid
(11) Park brake control solenoid
(24) Main combination valve
(T1) Brake pump discharge pressure test port
(T2) Brake accumulator charge pressure test port
Illustration 9 g00804537
Accumulator
(5) Protective cover
(6) Seal for the gas valve
(7) Gas valve
Unscrew protective cover (5) and remove seal (6) from gas valve (7).
Illustration 10 g00805885
Disconnect hose (11) from valve (10) at point (15). Ensure that the valve is closed.
Illustration 11 g00804539
(8) Pressure gauge
(16) Hose
(17) Valve body
(18) Gas valve key drive
(19) Purge valve
(20) Adapter
(21) Gas valve key
Ensure that purge valve (19) is closed. Install adapter (20) on the accumulator. Ensure that gas valve key (21) engages the accumulator gas valve. Fully tighten the adapter.
Use a half inch ratchet wrench to turn gas valve key drive (18). Turn the gas valve key drive counterclockwise to open gas valve (7) on the accumulator.
Table 3
Model Precharge Pressure
725 8000 200 kPa (1160 30 psi) at 21 °C (70 °F)
730 8000 200 kPa (1160 30 psi) at 21 °C (70 °F)
Pressure in the accumulator will be displayed on pressure gauges (8) and (9). Refer to table 3 for the required precharge pressure.If the pressure is correct, turn gas valve key drive (18) clockwise to close gas valve (7). Open valve (10) to release the pressure from the Tooling. Proceed to Step 13.
If the pressure is above the required precharge pressure, then the pressure must be decreased.
Slowly open valve (10) to reduce the pressure in the accumulator to the required precharge pressure. Close the valve when the required pressure is reached.
Turn gas valve key drive (18) clockwise to close gas valve (7). Open valve (10) to release the pressure from the Tooling.
If the pressure is below the required precharge pressure, then the pressure must be increased.
Reconnect hose (11) to valve (10) at point (15).
Attach regulator (14) to a nitrogen cylinder. Ensure that adjustment screw for the regulator is backed out completely to close the regulator.
Turn gas valve key drive (18) clockwise to close gas valve (7).
Open the shutoff valve on the nitrogen cylinder. The pressure in the nitrogen cylinder will be displayed on gauge (13).
Open the adjustment
Parts gear Caterpillar catalog:
4W9983
GEAR
Caterpillar
Caterpillar
4W9982
GEAR
Caterpillar
Caterpillar
4W9981
GEAR
Caterpillar
Caterpillar
4W9980
GEAR
Caterpillar
Caterpillar
4W9951
GEAR-IDLER
Caterpillar
Caterpillar
4W9772
GEAR
Caterpillar
Caterpillar
5004560
GEAR-HELICAL
Caterpillar
Caterpillar
5002419
GEAR
Caterpillar
Caterpillar
5002404
GEAR AS
Caterpillar
Caterpillar
4Y2945
GEAR
Caterpillar
Caterpillar
4Y2942
GEAR
Caterpillar
Caterpillar
4Y0298
GEAR & PINION
Caterpillar
Caterpillar