Information:
Equipment Ground Connection
Illustration 1 g03368914
Unit ground bar shall be connected in accordance with National Electrical Code, ANSI/NFPA 70, Article 250. Installer shall use UL Listed terminal connectors and install in accordance with terminal connector manufacturer instructions. Terminal connectors shall be used within UL rating limit and suitable for the application. A field wiring ground terminal shall be sized for the connection based on the minimum ground conductor size required by UL as shown in the corresponding column of Table 1.Over-current protection devices
For units without installed circuit breaker over-current protection option, installer shall use off package mounted UL Listed circuit breaker within 7.6 m (25 feet) of generator set.
Table 1
    Minimum Ground Conductor Size    
AWG or kcmil (mm2)
(Amps)     Copper     Aluminum or copper-clad aluminum    
400     1/0     (53.5)     3/0     (85.0)    
500     2/0     (67.4)     4/0     (107.2)    
600     2/0     (67.4)     4/0     (107.2)    
800     3/0     (85.0)     250     (127)    
1000     3/0     (85.0)     250     (127)    
1200     3/0     (85.0)     250     (127)    
1600     3/0     (85.0)     250     (127)    
2000     3/0     (85.0)     250     (127)    
2500     3/0     (85.0)     250     (127)    Field Wiring – EMCP Controller Interface
Installer shall use Class 1 wiring methods for all controller (customer) connections with following exception. Class 2 wiring methods shall be allowed for Class 2 controller interface wiring when Class 2 conductors are shielded with UL Listed/recognized insulation sleeve or conduit rated to 600V for each individual circuit.Batteries
Servicing of batteries is to be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.When replacing batteries, use the same number and the following type batteries:Cat Premium High Output (PHO) Batteries
Standard battery (wet) BCI Group 31, Calcium Lead Alloy Grid Design, 1000 CCA,Oversize battery (wet) BCI Group 4D, Calcium Lead Alloy Grid Design, 1400 CCA,Standard battery (dry) BCI Group 31, Calcium Lead Alloy Grid Design, 950 CCA,Standard battery (dry) BCI Group 4D, Low Maintenance, Hybrid Construction, 1300 CCA,
Do not dispose of battery or batteries in a fire. The battery is capable of exploding.
Do not open or mutilate the battery or batteries. Released electrolyte has been know to be harmful to the skin and eyes and to be toxic.
A battery presents a risk of electrical shock and high short circuit current.
Remove watches, rings, or other metal objects, 2) Use tools with insulated handles
The electrolyte is a dilute sulfuric acid that is harmful to the skin and eyes. It is electrically conductive and corrosive.
It is electrically conductive and corrosive. The following procedures are to be observed:
Wear full eye protection and protective clothing,
Where electrolyte contacts the skin, wash it off immediately with water,
Where electrolyte contacts the eyes, flush thoroughly and immediately with water and seek medical attention, and
Spilled electrolyte is to be washed down with an acid neutralizing agent. A common practice is to
Illustration 1 g03368914
Unit ground bar shall be connected in accordance with National Electrical Code, ANSI/NFPA 70, Article 250. Installer shall use UL Listed terminal connectors and install in accordance with terminal connector manufacturer instructions. Terminal connectors shall be used within UL rating limit and suitable for the application. A field wiring ground terminal shall be sized for the connection based on the minimum ground conductor size required by UL as shown in the corresponding column of Table 1.Over-current protection devices
For units without installed circuit breaker over-current protection option, installer shall use off package mounted UL Listed circuit breaker within 7.6 m (25 feet) of generator set.
Table 1
    Minimum Ground Conductor Size    
AWG or kcmil (mm2)
(Amps)     Copper     Aluminum or copper-clad aluminum    
400     1/0     (53.5)     3/0     (85.0)    
500     2/0     (67.4)     4/0     (107.2)    
600     2/0     (67.4)     4/0     (107.2)    
800     3/0     (85.0)     250     (127)    
1000     3/0     (85.0)     250     (127)    
1200     3/0     (85.0)     250     (127)    
1600     3/0     (85.0)     250     (127)    
2000     3/0     (85.0)     250     (127)    
2500     3/0     (85.0)     250     (127)    Field Wiring – EMCP Controller Interface
Installer shall use Class 1 wiring methods for all controller (customer) connections with following exception. Class 2 wiring methods shall be allowed for Class 2 controller interface wiring when Class 2 conductors are shielded with UL Listed/recognized insulation sleeve or conduit rated to 600V for each individual circuit.Batteries
Servicing of batteries is to be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.When replacing batteries, use the same number and the following type batteries:Cat Premium High Output (PHO) Batteries
Standard battery (wet) BCI Group 31, Calcium Lead Alloy Grid Design, 1000 CCA,Oversize battery (wet) BCI Group 4D, Calcium Lead Alloy Grid Design, 1400 CCA,Standard battery (dry) BCI Group 31, Calcium Lead Alloy Grid Design, 950 CCA,Standard battery (dry) BCI Group 4D, Low Maintenance, Hybrid Construction, 1300 CCA,
Do not dispose of battery or batteries in a fire. The battery is capable of exploding.
Do not open or mutilate the battery or batteries. Released electrolyte has been know to be harmful to the skin and eyes and to be toxic.
A battery presents a risk of electrical shock and high short circuit current.
Remove watches, rings, or other metal objects, 2) Use tools with insulated handles
The electrolyte is a dilute sulfuric acid that is harmful to the skin and eyes. It is electrically conductive and corrosive.
It is electrically conductive and corrosive. The following procedures are to be observed:
Wear full eye protection and protective clothing,
Where electrolyte contacts the skin, wash it off immediately with water,
Where electrolyte contacts the eyes, flush thoroughly and immediately with water and seek medical attention, and
Spilled electrolyte is to be washed down with an acid neutralizing agent. A common practice is to
Caterpillar parts catalog:
Parts gear Caterpillar catalog:
3P4855
GEAR PUMP GROUP
583K, 594, D8H, D8K, D9G
583K, 594, D8H, D8K, D9G
8S4368
GEAR (Idler-10 Teeth)
1673C, 1674, 1693, 245, 3306, 3406, 518, 621, 621B, 627B, 631C, 824B, 941, 950, 951B, 966C, 980C, D343, D4D, D5, D6C, D6D, D7F, D7G, D8H, D8K
1673C, 1674, 1693, 245, 3306, 3406, 518, 621, 621B, 627B, 631C, 824B, 941, 950, 951B, 966C, 980C, D343, D4D, D5, D6C, D6D, D7F, D7G, D8H, D8K
2P1078
GEAR
30/30, D8K, D9H, DEUCE
30/30, D8K, D9H, DEUCE
1S4282
GEAR ASSEM.
D342C, D8K
D342C, D8K
1M4156
GEAR (138 & 89 T.)
594, 594H, D8H, D8K, D9G, D9H
594, 594H, D8H, D8K, D9G, D9H
5M3996
GEAR (138 & 81 T.)
594, 594H, D8H, D8K, D9G, D9H
594, 594H, D8H, D8K, D9G, D9H
5M0549
GEAR (27 T.)
594, 594H, D8H, D8K, D9G, D9H
594, 594H, D8H, D8K, D9G, D9H
5M4427
GEAR (50 T.)
594, 594H, D8H, D8K, D9G, D9H
594, 594H, D8H, D8K, D9G, D9H
5M8007
GEAR (96 Teeth)
594H, D8H, D8K, D9G, D9H
594H, D8H, D8K, D9G, D9H
2P1076
GEAR (10 Teeth-Drive)
D8K, D9H
D8K, D9H
2P1079
GEAR (10 Teeth-Idler)
D8K, D9H
D8K, D9H
6P2776
GEAR (55 teeth)
583K, D8H, D8K
583K, D8H, D8K
1M0598
GEAR (53T. & 28T.)
983, D7F
983, D7F
4M7100
GEAR (108T.&94T.)
983, D7F
983, D7F
3K2230
GEAR (20T.)
955H, 983, 988B, D7F
955H, 983, 988B, D7F
3P4629
GEAR ASSEM. (10 teeth)
518C, 528, 528B, 530B, 54, D4E, D6D
518C, 528, 528B, 530B, 54, D4E, D6D
3P1657
GEAR (36 teeth)
518C, 528, 528B, 530B, 54
518C, 528, 528B, 530B, 54
3P4096
GEAR ASSEM.
594H, D9H
594H, D9H
3P4089
GEAR ASSEM.
594H, D9H
594H, D9H