1440468 GENERATOR AR Caterpillar parts
3406C
Rating:
Alternative (cross code) number:
CA1440468
144-0468
1440468
CA1440468
144-0468
1440468
GEN SET ENGINE, GENERATOR SET,
Compatible equipment models: 1440468:
Information:
Illustration 1 g00779068
Dimensions of the VR6 Voltage Regulator (A) 212.75 mm (8.376 inch) (B) 190.50 mm (7.500 inch) (C) 161.95 mm (6.376 inch) (D) 139.70 mm (5.500 inch) (E) 87.4 mm (3.441 inch)Description of Terminals
Note: When the voltage regulator is used with a permanent magnet generator, ensure that the jumpers are removed between the following terminals: 20 - 28, 22 - 30 and 24 - 26. For regulators that were manufactured before June 2003, ensure that a jumper is installed between terminals 28 and "GND".
Table 1
Number of the Terminal    Description    
GND     Ground    
2     Auxiliary input from VAR/PF Controller    
3     Auxiliary input from VAR/PF Controller    
4     This terminal is used in conjunction with terminal 7 for selecting internal voltage adjustment. Place the jumper between terminals 4 and 7 for using internal voltage adjustment. Remote voltage adjustment requires a remote voltage adjust potentiometer between terminals 6A and 7.    
5     1 Ampere Current Transformer (CT)    
5A     5 Ampere Current Transformer (CT)    
6     Common for the Current Transformer    
6A     Common connection for selectable features    
7     This terminal is used in conjunction with terminal 4 for selecting external voltage adjustment. Place the jumper between terminals 4 and 7 for using internal voltage adjustment. Remote voltage adjustment requires a remote voltage adjust potentiometer between terminals 6A and 7.    
8     Connect terminal 8 to terminal 6A in order to select a 1 V/Hz underfrequency slope.    
9     Connect terminal 9 to terminal 6A in order to select three-phase sensing.    
20     Sensing input on phase C    
22     Sensing input on phase A    
24     Sensing input on phase B    
26     Three-phase power input    
28     Single-phase power input or three-phase power input    
30     Single-phase power input or three-phase power input    
F1     Positive field lead    
F2     Negative field lead    
Terminals 26, 28, and 30 are designed to be connected directly to a power source that is NOT switched. Either a permanent magnet or the generator's output is preferred so the voltage will gradually build. Connecting the terminals directly to a switched power source may cause damage to the regulator unless an inrush current reduction device is utilized.
Internal Adjustments
Table 2
Adjustment    Description    
"DRP"     Adjustment of the Voltage Droop    
"FAC CAL"     This is the factory calibration of the voltage adjustment range. Adjustment by the customer is not required.    
"VLT ADJ"     Voltage Adjustment    
"UF"     Underfrequency Knee Adjustment    
"STB"     Stability Adjustment    
Caterpillar SIS machinery equipment:
Parts generator Caterpillar catalog:
1415526
GENERATOR AR
3406C
3406C
1415527
GENERATOR AR
3406C
3406C
1415530
GENERATOR AR
3406C
3406C
1415531
GENERATOR AR
3406C
3406C
1440566
GENERATOR AR
3406C
3406C
1586552
GENERATOR AR
3406C
3406C
1415541
GENERATOR GP
3406C
3406C
1415542
GENERATOR GP
3406C
3406C
1415543
GENERATOR GP
3406C
3406C
1440469
GENERATOR GP
3406C
3406C
1440578
GENERATOR GP
3406C
3406C
1440579
GENERATOR GP
3406C
3406C
2035755
GENERATOR GP
3512, 3512B, 3512C, 3516, SR4B
3512, 3512B, 3512C, 3516, SR4B
3382018
GENERATOR GP
3406C, 3456, C13, C15, C15 I6, C18, C18 I6, C9
3406C, 3456, C13, C15, C15 I6, C18, C18 I6, C9
3382009
GENERATOR AR
3406C, 3456, C13, C15, C15 I6, C18, C18 I6, C9
3406C, 3456, C13, C15, C15 I6, C18, C18 I6, C9
1287423
GENERATOR GP
3516, SR4
3516, SR4
7M0149
GENERATOR ASSEMBLY
583H, D8H, D9E
583H, D8H, D9E
5N8251
GENERATOR AR
3512, 3516
3512, 3516
1291499
GENERATOR AR
3306B
3306B
7W3117
GENERATOR GP
3512, 3516, SR4
3512, 3516, SR4
3247674
GENERATOR GP
3406C, 3456, C6.6, C9
3406C, 3456, C6.6, C9
3471824
GENERATOR AR
3512C, 3516, 3516B, G3520C, SR4B
3512C, 3516, 3516B, G3520C, SR4B
5N0063
GENERATOR GP
3306, G3306
3306, G3306
2947497
GENERATOR GP
3512B, 3516, 3516B, 3516C, PM3516, PMG3516