1662698 GENERATOR AR Caterpillar parts
3512B, SR4B
Rating:
Alternative (cross code) number:
CA1662698
166-2698
1662698
CA1662698
166-2698
1662698
GENERATOR, GENERATOR SET,
Information:
Table 1
Method of determining flow loss:    
    Pump flow at
690 kPa (100 psi)    
-     Pump flow at
6900 kPa (1000 psi)    
    Flow loss    
Table 2
Example of determining flow loss:    
   
217.6 L/min (57.5 US gpm)    
-    
196.8 L/min (52.0 US gpm)    
   
20.8 L/min (5.5 US gpm)    Flow loss that is expressed as a percentage of pump flow is used as a measure of pump performance.
Table 3
Method of determining percent of flow loss:    
Flow loss (L/min or US gpm)     ×     100     =     Percent of flow loss    
Pump flow at
690 kPa (100 psi)    
Table 4
Example of determining percent of flow loss:    
20.8 L (5.5 US gal)     ×     100     =     9.5%    
217.6 L/min (57.5 US gpm)    If the percent of flow loss is greater than 10%, the pump performance is inadequate.Note: The values in the examples are not set values for any specific pump or for any specific pump condition. See the Specification for your machine for the pump flow of a new pump at 690 kPa (100 psi) and at 6900 kPa (1000 psi).Machine Test
Install a flow meter. Run the engine at high idle. Measure the pump flow at 690 kPa (100 psi) and at 6900 kPa (1000 psi). Use these values in the following formula.
Table 5
    Pump flow at
690 kPa (100 psi)        
-     Pump flow at
6900 kPa (1000 psi)     ×     100     =     Percent of flow loss    
    Pump flow at
690 kPa (100 psi)    Bench Test
If the bench test can be performed at 6900 kPa (1000 psi) and at full pump rpm, determine the percent of flow loss by using the above formula.If the bench test cannot be performed at 6900 kPa (1000 psi) or at full pump rpm, run the pump shaft at 1000 rpm. Measure the pump flow at 690 kPa (100 psi) and at 6900 kPa (1000 psi). Use these values in the top portion of the following formula. For the bottom part of the formula, run the pump shaft at 2000 rpm. Measure the pump flow at 690 kPa (100 psi).
Table 6
    Pump flow at
690 kPa (100 psi)        
-     Pump flow at
6900 kPa (1000 psi)     ×     100     =     Percent of flow loss    
    Pump flow at
690 kPa (100 psi) and at 2000 rpm    
Caterpillar SIS machinery equipment:
Parts generator Caterpillar catalog:
1441825
GENERATOR GP
3512B, 3512C, 3516, 3516B, 3516C, G3512E, G3516B, G3516C, G3516E, SR4B
3512B, 3512C, 3516, 3516B, 3516C, G3512E, G3516B, G3516C, G3516E, SR4B
1479455
GENERATOR GP
3512, 3512B, 3516, G3516, G3516B, PM3512, SR4B
3512, 3512B, 3516, G3516, G3516B, PM3512, SR4B
1441819
GENERATOR GP
3512, 3512B, 3516, 3516B, G3516, G3516B, PM3516, PMG3516, SR4B
3512, 3512B, 3516, 3516B, G3516, G3516B, PM3516, PMG3516, SR4B
1441745
GENERATOR GP
3508, 3508B, SR4B
3508, 3508B, SR4B
1662703
GENERATOR GP
3512B, 3516, SR4B
3512B, 3516, SR4B
3185156
GENERATOR AR
3512B, G3520B, PM3512, SR4B
3512B, G3520B, PM3512, SR4B
1662674
GENERATOR AR
3508B, 3512, SR4B
3508B, 3512, SR4B
1442024
GENERATOR AR
3508, 3508B, SR4B
3508, 3508B, SR4B
1662693
GENERATOR GP
3512, 3512B, SR4B
3512, 3512B, SR4B
1662696
GENERATOR AR
3512, 3512B, SR4B
3512, 3512B, SR4B
1662694
GENERATOR AR
3512, 3512B, SR4B
3512, 3512B, SR4B
1662692
GENERATOR AR
3512, 3512B, SR4B
3512, 3512B, SR4B
1662690
GENERATOR AR
3512, SR4B
3512, SR4B
1662688
GENERATOR AR
3512, SR4B
3512, SR4B
1662686
GENERATOR AR
3512, SR4B
3512, SR4B
1662712
GENERATOR AR
3516, 3516B, SR4B
3516, 3516B, SR4B
1662710
GENERATOR AR
3516, 3516B, SR4B
3516, 3516B, SR4B
1662706
GENERATOR AR
3512B, 3516, SR4B
3512B, 3516, SR4B
1662704
GENERATOR AR
3512B, 3516, SR4B
3512B, 3516, SR4B
1662702
GENERATOR AR
3512B, SR4B
3512B, SR4B
1662700
GENERATOR AR
3512B, SR4B
3512B, SR4B