Table 1
Method of determining flow loss:    
    Pump flow at
690 kPa (100 psi)    
-     Pump flow at
6900 kPa (1000 psi)    
    Flow loss    
Table 2
Example of determining flow loss:    
   
217.6 L/min (57.5 US gpm)    
-    
196.8 L/min (52.0 US gpm)    
   
20.8 L/min (5.5 US gpm)    Flow loss that is expressed as a percentage of pump flow is used as a measure of pump performance.
Table 3
Method of determining percent of flow loss:    
Flow loss (L/min or US gpm)     ×     100     =     Percent of flow loss    
Pump flow at
690 kPa (100 psi)    
Table 4
Example of determining percent of flow loss:    
20.8 L (5.5 US gal)     ×     100     =     9.5%    
217.6 L/min (57.5 US gpm)    If the percent of flow loss is greater than 10%, the pump performance is inadequate.Note: The values in the examples are not set values for any specific pump or for any specific pump condition. See the Specification for your machine for the pump flow of a new pump at 690 kPa (100 psi) and at 6900 kPa (1000 psi).Machine Test
Install a flow meter. Run the engine at high idle. Measure the pump flow at 690 kPa (100 psi) and at 6900 kPa (1000 psi). Use these values in the following formula.
Table 5
    Pump flow at
690 kPa (100 psi)        
-     Pump flow at
6900 kPa (1000 psi)     ×     100     =     Percent of flow loss    
    Pump flow at
690 kPa (100 psi)    Bench Test
If the bench test can be performed at 6900 kPa (1000 psi) and at full pump rpm, determine the percent of flow loss by using the above formula.If the bench test cannot be performed at 6900 kPa (1000 psi) or at full pump rpm, run the pump shaft at 1000 rpm. Measure the pump flow at 690 kPa (100 psi) and at 6900 kPa (1000 psi). Use these values in the top portion of the following formula. For the bottom part of the formula, run the pump shaft at 2000 rpm. Measure the pump flow at 690 kPa (100 psi).
Table 6
    Pump flow at
690 kPa (100 psi)        
-     Pump flow at
6900 kPa (1000 psi)     ×     100     =     Percent of flow loss    
    Pump flow at
690 kPa (100 psi) and at 2000 rpm    


Parts generator Caterpillar catalog:

1441825 GENERATOR GP
3512B, 3512C, 3516, 3516B, 3516C, G3512E, G3516B, G3516C, G3516E, SR4B
1479455 GENERATOR GP
3512, 3512B, 3516, G3516, G3516B, PM3512, SR4B
1441819 GENERATOR GP
3512, 3512B, 3516, 3516B, G3516, G3516B, PM3516, PMG3516, SR4B
3185156 GENERATOR AR
3512B, G3520B, PM3512, SR4B
Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.