Operation Description:This procedure is for the parameter that has the alert indicator which is FLASHING constantly. This condition is caused by an undesired open circuit or a failed main display module.The main display module is unable to identify system errors in simple circuits. No service code is available in order to assist the operator with troubleshooting. A possible problem exists when the operation of an alert indicator does not correspond to a known condition of the machine. For example, the alert indicator always FLASHES regardless of the actual pressure of the engine oil. Before you start troubleshooting, ensure that a diagnostic code exists. For a description of normal conditions that cause these events, see the Operation and Maintenance Manual for the machine that is being serviced. Perform the following procedures only if a fault is suspected.Note: The indicator reflects the open or grounded condition of the switch inputs. When a switch input is open, the corresponding alert indicator FLASHES. When a switch input is grounded, the corresponding alert indicator is OFF. Therefore, in order to check a circuit, the service person opens the switch. Then, the service person grounds the switch. This action is done while the service person is watching for the correct result on the alert indicator. Test Step 1. LOCATE THE SWITCH.
Locate the switch which corresponds to the parameter that always FLASHES the alert indicator. (If necessary, use the Electrical System Schematic in order to assist in locating the switch.)Expected Result:The appropriate switch is located.Results:
OK - The appropriate switch is located. Proceed to test step 2.Test Step 2. CHECK THE SWITCH.
Disconnect the signal wire from the switch.
Place a jumper wire from the signal wire to the ground wire. (If a ground wire is not present, connect the signal wire to frame ground.)Expected Result:The alert indicator continues FLASHING.Results:
YES - The alert indicator continues FLASHING. The machine harness is open or the main display module has failed. Proceed to test step 3.
NO - The alert indicator stops FLASHING. The circuit is operating correctly. The switch has failed.Repair: Check or replace the switch.STOPTest Step 3. CHECK FOR AN OPEN HARNESS.
Turn the disconnect switch and the key start switch to the OFF position.
On the Electrical System Schematic, trace the signal wire from the switch to the main display module.
Determine the signal contact (connector contact) of the machine harness at the main display module.
Disconnect the machine harness from the main display module.
The jumper is in place from the previous test step.
At the machine harness connector for the main display, perform one of the following continuity checks:
Between the signal contact and contact 2
Between the signal contact and Frame ground (if a ground wire is not present at contact 2)Expected Result:The resistance is less than 5 ohms.Results:
YES - The resistance is less than 5 ohms. The harness is not causing the problem. The main display module has failed.Repair: It is unlikely that the main display module has failed. Exit this procedure and perform this procedure again. Also, recheck if the diagnostic code
Locate the switch which corresponds to the parameter that always FLASHES the alert indicator. (If necessary, use the Electrical System Schematic in order to assist in locating the switch.)Expected Result:The appropriate switch is located.Results:
OK - The appropriate switch is located. Proceed to test step 2.Test Step 2. CHECK THE SWITCH.
Disconnect the signal wire from the switch.
Place a jumper wire from the signal wire to the ground wire. (If a ground wire is not present, connect the signal wire to frame ground.)Expected Result:The alert indicator continues FLASHING.Results:
YES - The alert indicator continues FLASHING. The machine harness is open or the main display module has failed. Proceed to test step 3.
NO - The alert indicator stops FLASHING. The circuit is operating correctly. The switch has failed.Repair: Check or replace the switch.STOPTest Step 3. CHECK FOR AN OPEN HARNESS.
Turn the disconnect switch and the key start switch to the OFF position.
On the Electrical System Schematic, trace the signal wire from the switch to the main display module.
Determine the signal contact (connector contact) of the machine harness at the main display module.
Disconnect the machine harness from the main display module.
The jumper is in place from the previous test step.
At the machine harness connector for the main display, perform one of the following continuity checks:
Between the signal contact and contact 2
Between the signal contact and Frame ground (if a ground wire is not present at contact 2)Expected Result:The resistance is less than 5 ohms.Results:
YES - The resistance is less than 5 ohms. The harness is not causing the problem. The main display module has failed.Repair: It is unlikely that the main display module has failed. Exit this procedure and perform this procedure again. Also, recheck if the diagnostic code
Parts glass Caterpillar catalog:
3822263
GLASS
Caterpillar
Caterpillar
3822261
GLASS
Caterpillar
Caterpillar
3822250
GLASS
Caterpillar
Caterpillar
3822249
GLASS
Caterpillar
Caterpillar
5080792
GLASS-FRONT
Caterpillar
Caterpillar
5080791
GLASS
Caterpillar
Caterpillar
4783804
GLASS
Caterpillar
Caterpillar
4414184
GLASS
Caterpillar
Caterpillar
4386984
GLASS AS
Caterpillar
Caterpillar
3822344
GLASS
Caterpillar
Caterpillar
3822343
GLASS
Caterpillar
Caterpillar
3822311
GLASS
Caterpillar
Caterpillar