Table 1
Alarms and Default Conditions for Arming of the Alarms    
Alarm     Condition    
"CYL DEV"     The circuit for the input for engine rotation is open.
The temperature for arming of the parameters is achieved.
The start-up timer has expired.    
"CYL HI 1"    
"CYL HI 2"    
"TO HI 1"     The circuit for the input for engine rotation is open.    
"TO HI 2"    
"TI HI"    Note: Any alarm can be configured to be armed by the input for engine rotation only. Any alarm can also be configured to be armed by all of the conditions. However, custom wiring, a computer, and the proper software are required. For more information, consult the appropriate Caterpillar Engine Customer Service.Input for Engine Rotation - It is important for the circuit of this input to be open during normal engine operation. When the circuit is open, the scanner can activate alarms.When the circuit is grounded, all the alarms are deactivated and the engine is not protected against problems with exhaust temperatures.It is not necessary to connect the circuit for input of engine rotation. The circuit is left open by the factory.Note: The arming temperature and the start-up timer are adjusted with the "SETPTS" menu. Refer to Systems Operation, "System Configuration Parameters".Average MET - The average MET is the setpoint value that the value for "Average Cylinder Temperature" must meet in order for the start-up sequence to be enabled.Arming Temperature - Arming temperature is an adjustable temperature value that is used in the arming sequence. When the arming temperature is reached, the start-up timer is initiated. To arm the alarms, the average cylinder temperature must rise above the arming temperature. This temperature can be reprogrammed with the keypad. A typical arming temperature would be 400 °C (752 °F).The average cylinder temperature must stay above the arming temperature during normal operation. If the average cylinder temperature becomes less than the arming temperature, the alarms that depend on the arming temperature are deactivated.Start-up Timer - The start-up timer starts when the arming temperature is achieved. When the start-up timer is running, the display shows the time in minutes and in seconds until the timer expires. The display shows "TIMER", "xxm", and "xxs".If no alarms are configured to use the timer, the screen for the start-up timer is not displayed during start-up of the scanner.For arming of the selected alarms, the average cylinder temperature must stay above the arming temperature until the timer expires. Otherwise, the timer restarts.
"ENTER/ACK" key To cancel the start-up timer, press the "ENTER/ACK" key.
"RESET" key To reset the timer to the full amount of programmed time, press the "RESET" key.
"ESC" key
Up Arrow and Down Arrow keys To display the normal screen during operation of the timer, press the "ESC" key or press one of the arrow keys. To return to the screen for the start-up timer, press the "ESC" key again.
Caterpillar parts catalog:
Parts glass Caterpillar catalog:
5259446
GLASS
Caterpillar
Caterpillar
5259445
GLASS
Caterpillar
Caterpillar
5259444
GLASS
Caterpillar
Caterpillar
5259443
GLASS
Caterpillar
Caterpillar
5259440
GLASS-FRONT
Caterpillar
Caterpillar
4670994
GLASS AS-DOOR
Caterpillar
Caterpillar
3705470
GLASS
Caterpillar
Caterpillar
3575249
GLASS
Caterpillar
Caterpillar
5125139
GLASS AS-SIGHT
Caterpillar
Caterpillar
5481523
GLASS
Caterpillar
Caterpillar
5481522
GLASS
Caterpillar
Caterpillar
5389868
GLASS AS
Caterpillar
Caterpillar