6N2337 GOV & FUEL INJ PUMP GP Caterpillar parts
225, 3208, 613B
Rating:
Alternative (cross code) number:
CA6N2337
6N-2337
6N2337
CA6N2337
6N-2337
6N2337
Weight: 0.40 pounds 0 kg.
EXCAVATOR, WHEEL TRACTOR,
Compatible equipment models: 6N2337:
Information:
A low reading is an indication that the battery needs to be charged. But for a very low reading, a more thorough test is needed. Test the voltage again and the specific gravity of the electrolyte in the separate cells. Use the 5P957 or 5P3514 Coolant and Battery Tester to check the specific gravity. Follow the recommendations below when voltage and specific gravity are used to check the condition of the battery or batteries:
Use the circuit voltage test to check for normal operation of an electrical system. The lamps of the tester will be activated when a complete circuit is made. The lamps are for a 24 Volt system and are not visible (activated but not seen) in the range of 10 Volts or less.
In this voltage range, a meter can be used for the Circuit Voltage Test to check for complete circuits. The meter can also be used to check the voltage decrease in a circuit. Normally, there is a 1.0 to 1.5 Volt decrease when a solenoid is activated. This is caused by a current flow through the solenoid back to the battery.
Use the Circuit Continuity Test-Ground Seeking to find a damaged (frayed) or broken harness. This is a common problem which causes a short circuit. If a continuity test lamp becomes visible as the serviceman turns the selector switch, this is an indication of a ground on the circuit respective to the selector switch position. This same test can also be used to check for open circuits. The opposite end of the harness is grounded. If there is an open circuit, the continuity test lamp will not become visible at the selector switch position.
Use the Circuit Continuity Test-Short Seeking to find internal continuities. Turn the selector switch of the tester. If any of the lamps other than the one respective to the selector position becomes visible, there is continuity between the selector position and the one or more circuits respective to the other lamps which have become visible.
To check a solenoid for its minimum rate of voltage, use the Solenoid Test on the Special Instruction. When the tester is given a full 24 Volts, the voltage decrease over the resistance that is built into the tester will give an indication of the voltage rate of the solenoid.
All of these circuit tests are in schematic form on Special Instruction SEHS7153. There is also a schematic of the 5P6590 Wiring Harness Tester.
Special Instruction Form SEHS7153 is to be used with the 5P6590 Wiring Harness Tester Group.
Use the circuit voltage test to check for normal operation of an electrical system. The lamps of the tester will be activated when a complete circuit is made. The lamps are for a 24 Volt system and are not visible (activated but not seen) in the range of 10 Volts or less.
In this voltage range, a meter can be used for the Circuit Voltage Test to check for complete circuits. The meter can also be used to check the voltage decrease in a circuit. Normally, there is a 1.0 to 1.5 Volt decrease when a solenoid is activated. This is caused by a current flow through the solenoid back to the battery.
Use the Circuit Continuity Test-Ground Seeking to find a damaged (frayed) or broken harness. This is a common problem which causes a short circuit. If a continuity test lamp becomes visible as the serviceman turns the selector switch, this is an indication of a ground on the circuit respective to the selector switch position. This same test can also be used to check for open circuits. The opposite end of the harness is grounded. If there is an open circuit, the continuity test lamp will not become visible at the selector switch position.
Use the Circuit Continuity Test-Short Seeking to find internal continuities. Turn the selector switch of the tester. If any of the lamps other than the one respective to the selector position becomes visible, there is continuity between the selector position and the one or more circuits respective to the other lamps which have become visible.
To check a solenoid for its minimum rate of voltage, use the Solenoid Test on the Special Instruction. When the tester is given a full 24 Volts, the voltage decrease over the resistance that is built into the tester will give an indication of the voltage rate of the solenoid.
All of these circuit tests are in schematic form on Special Instruction SEHS7153. There is also a schematic of the 5P6590 Wiring Harness Tester.
Special Instruction Form SEHS7153 is to be used with the 5P6590 Wiring Harness Tester Group.
Caterpillar SIS machinery equipment:
Caterpillar SIS
3208 INDUSTRIAL ENGINES 90N06121-37284 »
6N-2337
GOV & FUEL INJ PUMP GP
3208 VEHICULAR ENGINE 51U01043-01043 (MACHINE) »
6N-2337
GOV & FUEL INJ PUMP GP
613B TRACTOR 38W00001-UP (MACHINE) POWERED BY 3208 ENGINE »
6N-2337
GOV & FUEL INJ PUMP GP
225 EXCAVATOR 51U02034-02831 (MACHINE) POWERED BY 3208 ENGINE »
6N-2337
GOV & FUEL INJ PUMP GP
3208 TRUCK ENGINE COVERING ENGINE ARRANGEMENTS FOR FORD MOTO 40S00001-UP »
6N-2337
GOV & FUEL INJ PUMP GP
3208 TRUCK ENGINE- COVERING ENGINE ARRANGEMENTS FOR INTERNAT 40S00001-UP »
6N-2337
GOV & FUEL INJ PUMP GP
3208 TRUCK ENGINE- COVERING ENGINE ARRANGEMENTS FOR GENERAL 40S00001-UP »
6N-2337
GOV & FUEL INJ PUMP GP
3208 TRUCK ENGINE- COVERING ENGINE ARRANGEMENTS FOR WHITE MO 40S00001-UP »
6N-2337
GOV & FUEL INJ PUMP GP
225 EXCAVATOR 51U02832-UP (MACHINE) POWERED BY 3208 ENGINE »
6N-2337
GOV & FUEL INJ PUMP GP
3208 INDUSTRIAL ENGINE 90N37285-52892 »
6N-2337
GOVERNOR AND FUEL INJECTION PUMP GROUP
3208 MARINE ENGINE 75V00001-UP »
6N-2337
PUMP GP-GOV & FUEL INJ
3208 INDUSTRIAL ENGINE 90N00001-06120 »
6N-2337
GOV & FUEL INJ PUMP GP
3208 TRUCK ENGINE COVERING ENGINE ARRANGEMENTS 9L6082 9L6260 40S00001-UP »
6N-2337
GOV & FUEL INJ PUMP GP
Caterpillar parts catalog:
Parts gov Caterpillar catalog:
6N1085
GOV & FUEL INJ PUMP GP
225, 3160, 3208
225, 3160, 3208
9N3757
GOV & FUEL INJ PUMP GP
3208, D4D
3208, D4D
4W5615
GOV & FUEL INJ PUMP GP
225, 227
225, 227
4N2128
GOV & FUEL INJ PUMP GP
225, 3160, 613B
225, 3160, 613B
8N8592
GOV & FUEL INJ PUMP GP
225, 3208, 613B
225, 3208, 613B
8N8595
GOV & FUEL INJ PUMP GP
225, 227, 3208
225, 227, 3208
8N1045
GOV & FUEL INJ PUMP GP
225, 3208
225, 3208
6N5356
GOV & FUEL INJ PUMP GP
120G, 130G, 215, 225, 3304, 518, 920, 930, 941, 950, 951B, 955K, 955L, D4D, D4E
120G, 130G, 215, 225, 3304, 518, 920, 930, 941, 950, 951B, 955K, 955L, D4D, D4E
6N3472
GOV & FUEL INJ PUMP GP
561C, 561D, D5, D5B, D6C
561C, 561D, D5, D5B, D6C
6N0260
GOV & FUEL INJ PUMP GP
627B, D6C
627B, D6C
4N8295
GOV & FUEL INJ PUMP GP
776, 777
776, 777
4N1834
GOV & FUEL INJ PUMP GP
120G, 130G, 215, 225, 3304, 518, 920, 930, 930R, 941, 950, 951B, 955K, 955L, D4D, D4E
120G, 130G, 215, 225, 3304, 518, 920, 930, 930R, 941, 950, 951B, 955K, 955L, D4D, D4E
6N0247
GOV & FUEL INJ PUMP GP
950, D4D
950, D4D
6N0243
GOV & FUEL INJ PUMP GP
920, 930, 941, 950, 951B, D4D, D4E
920, 930, 941, 950, 951B, D4D, D4E
6N2840
GOV & FUEL INJ PUMP GP
140B, 977K, 977L, D5, D6C
140B, 977K, 977L, D5, D6C
4W7795
GOV & FUEL INJ PUMP GP
561D, D5B
561D, D5B
8N4123
GOV & FUEL INJ PUMP GP
936, 950B, 950B/950E, 963, CS-643
936, 950B, 950B/950E, 963, CS-643