Information:
Implement Lockout Switch
Illustration 8 g03447706The implement lockout switch is designed to de-energize the implement lockout solenoid. The ECM will provide power to the solenoid through the implement lockout switch. The circuit is open and the implement lockout solenoid is de-energized, when the switch is placed in the LOCKED position. The switch should be in the LOCKED position before any of the following conditions occur:
The operator exits the machine.
The machine is serviced.
The machine is left unattended.The switch affects the system in the following manner:LOCKED - The implement lockout solenoid is de-energized. The implement system is no longer operable.UNLOCKED - The implement lockout solenoid is energized. The implement system is enabled.The switch is a single-pole rocker switch. The switch has a normally closed contact and a normally open contact. One contact connects to the switch input of the ECM. The other contact connects to the feedback input of the ECM and to the lockout solenoid. The pole of the switch connects to the output of the ECM for the implement lockout solenoid. The ECM can always determine whether the switch is in the LOCKED position or the UNLOCKED position. The two input circuits are used for diagnostic purposes. The ECM will detect a failure in the circuit if the two circuits of the switch are ever in the same state. The ECM will also record a diagnostic code. The diagnostic code that is associated with the implement lockout switch is CID 0490.Winch On/Start Switch
Illustration 9 g03376439The winch on/start switch is a single pole switch. The switch has a normally connected and normally open contact. When the pushbutton on the winch control handle is not depressed, the normally connected contact is connected to the return and the normally open contact floats to a high-voltage state. When the pushbutton is depressed, the normally open contact is connected to the return and the normally connected contact floats to a high-voltage state. Based on the voltage state of the two ECM contacts, the ECM determines if the on/start switch pushbutton has been depressed. The button engages the on/start feature for the winch.Outputs
The ECM responds to decisions by sending electrical signals to the outputs. The outputs can create an action or the outputs can provide information to the operator or the service technician.Proportional Solenoids
Illustration 10 g03347475
Blade Raise/Lower Solenoids
Blade Tilt Solenoids
All proportional solenoids in the implement system are
Illustration 8 g03447706The implement lockout switch is designed to de-energize the implement lockout solenoid. The ECM will provide power to the solenoid through the implement lockout switch. The circuit is open and the implement lockout solenoid is de-energized, when the switch is placed in the LOCKED position. The switch should be in the LOCKED position before any of the following conditions occur:
The operator exits the machine.
The machine is serviced.
The machine is left unattended.The switch affects the system in the following manner:LOCKED - The implement lockout solenoid is de-energized. The implement system is no longer operable.UNLOCKED - The implement lockout solenoid is energized. The implement system is enabled.The switch is a single-pole rocker switch. The switch has a normally closed contact and a normally open contact. One contact connects to the switch input of the ECM. The other contact connects to the feedback input of the ECM and to the lockout solenoid. The pole of the switch connects to the output of the ECM for the implement lockout solenoid. The ECM can always determine whether the switch is in the LOCKED position or the UNLOCKED position. The two input circuits are used for diagnostic purposes. The ECM will detect a failure in the circuit if the two circuits of the switch are ever in the same state. The ECM will also record a diagnostic code. The diagnostic code that is associated with the implement lockout switch is CID 0490.Winch On/Start Switch
Illustration 9 g03376439The winch on/start switch is a single pole switch. The switch has a normally connected and normally open contact. When the pushbutton on the winch control handle is not depressed, the normally connected contact is connected to the return and the normally open contact floats to a high-voltage state. When the pushbutton is depressed, the normally open contact is connected to the return and the normally connected contact floats to a high-voltage state. Based on the voltage state of the two ECM contacts, the ECM determines if the on/start switch pushbutton has been depressed. The button engages the on/start feature for the winch.Outputs
The ECM responds to decisions by sending electrical signals to the outputs. The outputs can create an action or the outputs can provide information to the operator or the service technician.Proportional Solenoids
Illustration 10 g03347475
Blade Raise/Lower Solenoids
Blade Tilt Solenoids
All proportional solenoids in the implement system are
Parts grapple Caterpillar catalog:
2508142
GRAPPLE AR-OR
Caterpillar
Caterpillar
2508141
GRAPPLE AR-OR
Caterpillar
Caterpillar
2508140
GRAPPLE AR-OR
Caterpillar
Caterpillar
2508139
GRAPPLE AR-OR
Caterpillar
Caterpillar
2508138
GRAPPLE AR-OR
Caterpillar
Caterpillar
2508137
GRAPPLE AR-OR
Caterpillar
Caterpillar
2508144
GRAPPLE AR-OR
Caterpillar
Caterpillar
2508145
GRAPPLE AR-OR
Caterpillar
Caterpillar
2508146
GRAPPLE AR-OR
Caterpillar
Caterpillar
2508147
GRAPPLE AR-OR
Caterpillar
Caterpillar
2508148
GRAPPLE AR-OR
Caterpillar
Caterpillar
2508149
GRAPPLE AR-OR
Caterpillar
Caterpillar