4I4641 GROMMET Caterpillar parts
320 L, 320B, 320C, 320D L, 320D LN, 322, 322 FM L, 322 LN, 322B, 322B L, 322B LN, 323D L, 323D LN, 323D SA
Rating:
Alternative (cross code) number:
CA4I4641
4I-4641
4I4641
CA4I4641
4I-4641
4I4641
Weight: 0.25 pounds 0 kg.
Information:
GROOVE WIDTH
36
mm
ID/WIDTH
87
mm
LARGER OD
115
mm
RADIUSED CHAMFER
Y
SMALLER OD
95
mm
SPLIT
N
THICKNESS
48
mm
EXCAVATOR, MOBILE HYD POWER UNIT,
Compatible equipment models: 4I4641:
Information:
System configuration parameters are parameters that affect emissions, power of the engine, and other features. The parameters are programmed at the factory. In most cases, the parameters do not need to be changed. You must reprogram the system configuration parameters if the Electronic Control Module (ECM) is replaced and/or if you reprogram the engine rating. You do not need to reprogram the system configuration parameters if you replace the flash file. Proper values for these parameters are available on Caterpillar Electronic Technician (ET). Certain system configuration parameters are also stamped on the engine information plate.The following functions will be performed with an engine that has EMCP II:
Automatic Start/Stop
Air shutoff
CooldownNote: Changing the parameters that are protected by factory passwords may cause your Caterpillar warranty to be voided.
Engine Serial Number
Program the engine serial number to match the engine information plate. The serial number is not programmed on a new ECM.Rated Fuel Position
This parameter is used to set engine power. A factory password is required to change this setting.
Table 1
Minimum Default Maximum
Minimum Rack Engine Dependent Engine Dependent Acceleration Delay
When the engine is started, the ECM will limit the engine to low idle. The ECM will no longer limit the engine rpm when the following conditions exist:
The engine oil pressure is above 70 kPa (10 psi).
The acceleration delay is reached.Programming this parameter to 0 will disable this function.Note: If the engine is configured to operate in direct fuel control mode, this parameter is disabled.
Table 2
Minimum Default Maximum
0 seconds 0 seconds 60 seconds Acceleration Ramp Rate
The acceleration ramp rate is the maximum ramp rate of the engine rpm. The desired engine rpm will be set to low idle until the engine rpm reaches 400 rpm. When the engine rpm becomes greater than 400 rpm, desired engine rpm will start increasing until the required desired engine rpm is reached.Note: If the engine is configured to operate in "Direct Fuel Control Mode", this parameter is disabled.
Table 3
Minimum rpm per second Default rpm per second Maximum rpm per second
1 rpm/sec 250 rpm/sec 750 rpm/sec Low Idle
The parameter defines the low idle rpm.Note: If the engine is configured to operate in direct fuel control mode, this parameter is disabled.
Table 4
Minimum Default Maximum
810 rpm 1000 rpm 1000 rpm Cooldown Speed
This parameter defines the engine rpm during the cooldown period.
Table 5
Minimum Default Maximum
810 rpm 1000 rpm 1800 rpm Cooldown Period
This parameter defines the duration of engine operation at the cooldown speed. Programming this parameter to 0 will disable this function.Note:
Automatic Start/Stop
Air shutoff
CooldownNote: Changing the parameters that are protected by factory passwords may cause your Caterpillar warranty to be voided.
Engine Serial Number
Program the engine serial number to match the engine information plate. The serial number is not programmed on a new ECM.Rated Fuel Position
This parameter is used to set engine power. A factory password is required to change this setting.
Table 1
Minimum Default Maximum
Minimum Rack Engine Dependent Engine Dependent Acceleration Delay
When the engine is started, the ECM will limit the engine to low idle. The ECM will no longer limit the engine rpm when the following conditions exist:
The engine oil pressure is above 70 kPa (10 psi).
The acceleration delay is reached.Programming this parameter to 0 will disable this function.Note: If the engine is configured to operate in direct fuel control mode, this parameter is disabled.
Table 2
Minimum Default Maximum
0 seconds 0 seconds 60 seconds Acceleration Ramp Rate
The acceleration ramp rate is the maximum ramp rate of the engine rpm. The desired engine rpm will be set to low idle until the engine rpm reaches 400 rpm. When the engine rpm becomes greater than 400 rpm, desired engine rpm will start increasing until the required desired engine rpm is reached.Note: If the engine is configured to operate in "Direct Fuel Control Mode", this parameter is disabled.
Table 3
Minimum rpm per second Default rpm per second Maximum rpm per second
1 rpm/sec 250 rpm/sec 750 rpm/sec Low Idle
The parameter defines the low idle rpm.Note: If the engine is configured to operate in direct fuel control mode, this parameter is disabled.
Table 4
Minimum Default Maximum
810 rpm 1000 rpm 1000 rpm Cooldown Speed
This parameter defines the engine rpm during the cooldown period.
Table 5
Minimum Default Maximum
810 rpm 1000 rpm 1800 rpm Cooldown Period
This parameter defines the duration of engine operation at the cooldown speed. Programming this parameter to 0 will disable this function.Note:
Caterpillar parts catalog:
Parts grommet Caterpillar catalog:
9K8878
GROMMET
528, 528B, 530B
528, 528B, 530B
8Y6838
GROMMET
518C
518C
4B6049
GROMMET
518, 518C
518, 518C
1158728
GROMMET
320C, 320D FM, 320D FM RR, 322B, 322B L, 322B LN, 322C, 322C FM, 324D FM, 324D FM LL, 325C, 325D FM, 325D FM LL, 328D LCR, 330B, 330B L, 330C, 330C FM, 330C L, 330C MH, 330D FM, 330D L, 330D LN, 330D ...
320C, 320D FM, 320D FM RR, 322B, 322B L, 322B LN, 322C, 322C FM, 324D FM, 324D FM LL, 325C, 325D FM, 325D FM LL, 328D LCR, 330B, 330B L, 330C, 330C FM, 330C L, 330C MH, 330D FM, 330D L, 330D LN, 330D ...
2510464
GROMMET
324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325D, 325D FM, 325D FM LL, 325D L, 325D MH, 326D L, 329D, 329D L, 329D LN, M325D L MH, M325D MH
324D, 324D FM, 324D FM LL, 324D L, 324D LN, 325D, 325D FM, 325D FM LL, 325D L, 325D MH, 326D L, 329D, 329D L, 329D LN, M325D L MH, M325D MH
1461228
GROMMET
320B FM LL, 320C FM, 320D FM, 322C, 322C FM, 325C FM, 330C FM
320B FM LL, 320C FM, 320D FM, 322C, 322C FM, 325C FM, 330C FM
7Y5579
GROMMET
320 L, 320B, 320C, 320N
320 L, 320B, 320C, 320N
1691490
GROMMET
550, 550B, 560B, 570, 570B, 580, 580B
550, 550B, 560B, 570, 570B, 580, 580B
1751292
GROMMET
320B, 322B LN, 325B L, 330B L, 345B II, 345B L
320B, 322B LN, 325B L, 330B L, 345B II, 345B L
1425535
GROMMET
1390, 2590, 320B, 320B FM LL, 322B LN, 325B, 325B L, 330B, 330B L, 336F L, 541, 541 2, 551, M325B, W330B
1390, 2590, 320B, 320B FM LL, 322B LN, 325B, 325B L, 330B, 330B L, 336F L, 541, 541 2, 551, M325B, W330B
4I4653
GROMMET
320 L, 320B, 320C, 320D L, 320D LN, 320E LN, 320N, 322, 322 FM L, 322 LN, 322B, 322B L, 322B LN, 322C, 323D L, 323D LN, 323D SA, 323E L, 325C, 345B, 345B II, 345B II MH, 345B L, W345B II
320 L, 320B, 320C, 320D L, 320D LN, 320E LN, 320N, 322, 322 FM L, 322 LN, 322B, 322B L, 322B LN, 322C, 323D L, 323D LN, 323D SA, 323E L, 325C, 345B, 345B II, 345B II MH, 345B L, W345B II
1597731
GROMMET
322B, 322B L, 322B LN
322B, 322B L, 322B LN