2192499 GUARD GP-BOTTOM Caterpillar parts
M322C
Rating:
Alternative (cross code) number:
CA2192499
219-2499
2192499
CA2192499
219-2499
2192499
WHEELED EXCAVATOR,
Compatible equipment models: 2192499:
Information:
portion of the memory within the GSC stores the setpoints of important conditions of the genset. The setpoints are found in the following service modes: "Engine/Generator Programming" (OP5), "Spare Input/Output Programming" (OP6) and "Voltmeter/Ammeter Programming" (OP8). The GSC detects a CID 268 when the data for the setpoint is invalid or out of range. After detecting a CID 268, the GSC sets the affected setpoints to the default value. For more information regarding setpoints and default values, see the following topics:
Systems Operation, "Engine/Generator Programming OP5"
Systems Operation, "Spare Input/Output Programming OP6"
Systems Operation, "Voltmeter/Ammeter Programming OP8"ProcedureElectrical interference is a possible cause of a CID 268 FMI 2.This procedure is for a CID 268 that is active or inactive. Clear the diagnostic code from the fault log after troubleshooting is complete.The GSC treats a CID 268 as an alarm fault or a shutdown fault. This will depend on the particular setpoint with the incorrect data. The setpoint for the ring gear teeth (P09) and the setpoint for the engine overspeed (P10) are treated as shutdown faults when the particular data is corrupted. All other setpoints are treated as alarm faults when the particular data is corrupted.Note: If the fault shutdown indicator is FLASHING and the 6 to 9 jumper is NOT installed on the ECS, then the jumper must be temporarily installed. The GSC setpoints must be programmed in OFF/RESET when a fault shutdown is active. If the fault alarm indicator is FLASHING the GSC can be programmed with the ECS in any position.
Check the setpoints.
View the setpoints that are stored in the memory of the GSC. See Systems Operation, "Engine/Generator Setpoint Viewing OP2".
Also check the spare input/output programming (OP6) and the voltmeter/ammeter programming (OP8).
Compare the stored setpoints to the specified setpoints of the particular genset. Expected Result: The stored setpoints and specified setpoints should match. Results:
OK - All the setpoints match. Start the engine. Verify that the CID 268 FMI 2 is active. If the fault remains active, replace the GSC. See Testing And Adjusting, "EMCP Electronic Control (Generator Set) - Replace". If the fault was inactive prior to performing this procedure, then these steps should have corrected the fault. STOP.
NOT OK - One or more of the setpoints do not match. Program the setpoints. See Systems Operation, "Engine/Generator Programming OP5", Systems Operation, "Spare Input/Output Programming OP6", and Systems Operation, "Voltmeter/Ammeter Programming OP8". STOP.
Systems Operation, "Engine/Generator Programming OP5"
Systems Operation, "Spare Input/Output Programming OP6"
Systems Operation, "Voltmeter/Ammeter Programming OP8"ProcedureElectrical interference is a possible cause of a CID 268 FMI 2.This procedure is for a CID 268 that is active or inactive. Clear the diagnostic code from the fault log after troubleshooting is complete.The GSC treats a CID 268 as an alarm fault or a shutdown fault. This will depend on the particular setpoint with the incorrect data. The setpoint for the ring gear teeth (P09) and the setpoint for the engine overspeed (P10) are treated as shutdown faults when the particular data is corrupted. All other setpoints are treated as alarm faults when the particular data is corrupted.Note: If the fault shutdown indicator is FLASHING and the 6 to 9 jumper is NOT installed on the ECS, then the jumper must be temporarily installed. The GSC setpoints must be programmed in OFF/RESET when a fault shutdown is active. If the fault alarm indicator is FLASHING the GSC can be programmed with the ECS in any position.
Check the setpoints.
View the setpoints that are stored in the memory of the GSC. See Systems Operation, "Engine/Generator Setpoint Viewing OP2".
Also check the spare input/output programming (OP6) and the voltmeter/ammeter programming (OP8).
Compare the stored setpoints to the specified setpoints of the particular genset. Expected Result: The stored setpoints and specified setpoints should match. Results:
OK - All the setpoints match. Start the engine. Verify that the CID 268 FMI 2 is active. If the fault remains active, replace the GSC. See Testing And Adjusting, "EMCP Electronic Control (Generator Set) - Replace". If the fault was inactive prior to performing this procedure, then these steps should have corrected the fault. STOP.
NOT OK - One or more of the setpoints do not match. Program the setpoints. See Systems Operation, "Engine/Generator Programming OP5", Systems Operation, "Spare Input/Output Programming OP6", and Systems Operation, "Voltmeter/Ammeter Programming OP8". STOP.
Caterpillar SIS machinery equipment:
Caterpillar parts catalog:
Parts guard Caterpillar catalog:
1884940
GUARD GP-VANDALISM
M313C, M313D, M315C, M315D, M316C, M316D, M318C, M318C MH, M318D, M318D MH, M322C, M322D, M322D MH, M325D L MH, M325D MH
M313C, M313D, M315C, M315D, M316C, M316D, M318C, M318C MH, M318D, M318D MH, M322C, M322D, M322D MH, M325D L MH, M325D MH
2387016
GUARD GP-FAN
M315C, M316C, M318C, M318C MH, M322C
M315C, M316C, M318C, M318C MH, M322C
2134640
GUARD GP-WINDOW
M313C, M313D, M315C, M315D, M316C, M316D, M318C, M318C MH, M318D, M318D MH, M322C, M322D, M322D MH, M325C MH, M325D L MH, M325D MH, M330D
M313C, M313D, M315C, M315D, M316C, M316D, M318C, M318C MH, M318D, M318D MH, M322C, M322D, M322D MH, M325C MH, M325D L MH, M325D MH, M330D
1884938
GUARD AR-OVERHEAD
M313C, M315C, M316C, M318C, M318C MH, M322C, M325C MH
M313C, M315C, M316C, M318C, M318C MH, M322C, M325C MH
2413621
GUARD GP-FAN
M315C, M316C, M318C, M318C MH, M322C
M315C, M316C, M318C, M318C MH, M322C
1882813
GUARD GP-FAN
M313C, M315C, M316C, M318C, M318C MH, M322C
M313C, M315C, M316C, M318C, M318C MH, M322C
2537126
GUARD GP-FAN
M318C, M322C
M318C, M322C
2239606
GUARD GP-BELT
M316C, M318C, M318C MH, M322C
M316C, M318C, M318C MH, M322C
1984648
GUARD GP-BOTTOM
M322C
M322C
2567452
GUARD GP-FAN
M318C, M322C
M318C, M322C
1932153
GUARD AS
312C, 312D, 315C, 315D L, 318C, 319C, 319D, 320C, 322C, 323D L, 323D LN, 324D, 324D LN, 325C, 325D, 325D L, 329D L, 330C, 330C L, 330D, 330D L, 330D LN, 330D MH, 336D L, 336D LN, 345C, 345C L, 345D, 3...
312C, 312D, 315C, 315D L, 318C, 319C, 319D, 320C, 322C, 323D L, 323D LN, 324D, 324D LN, 325C, 325D, 325D L, 329D L, 330C, 330C L, 330D, 330D L, 330D LN, 330D MH, 336D L, 336D LN, 345C, 345C L, 345D, 3...
2162180
GUARD AS
M313C, M313D, M315C, M315D, M315D 2, M316C, M316D, M317D 2, M318C, M318C MH, M318D, M318D MH, M322C, M322D, M322D MH, M325D L MH, M325D MH
M313C, M313D, M315C, M315D, M315D 2, M316C, M316D, M317D 2, M318C, M318C MH, M318D, M318D MH, M322C, M322D, M322D MH, M325D L MH, M325D MH
3802609
GUARD GP-DAMPER
G3516H
G3516H
2142043
GUARD AR
330C FM
330C FM
3157601
GUARD GP-BUCKET
924H, 928HZ
924H, 928HZ
2773556
GUARD GP-FUEL TANK
D6K, D6K LGP
D6K, D6K LGP
1756760
GUARD GP-WINDOW
914G, 924G, 924GZ, 924H, 924HZ, 928G, 928HZ, 930G, 938G II, IT14G, IT28G, IT38G II
914G, 924G, 924GZ, 924H, 924HZ, 928G, 928HZ, 930G, 938G II, IT14G, IT28G, IT38G II
1753831
GUARD GP-TRACK GUIDE
572R II, D7R II
572R II, D7R II
1914957
GUARD GP-LINES
TK1051
TK1051
6I9172
GUARD GP
572R, D7H, D7R
572R, D7H, D7R
1564557
GUARD GP-LINES
924G, 924GZ, 924H
924G, 924GZ, 924H
2134562
GUARD GP-WINDOW
TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
TH220B, TH330B, TH340B, TH350B, TH355B, TH460B, TH560B, TH580B
2403015
GUARD AR-VANDALISM
320C, 320C L
320C, 320C L