2612083 GUARD AS-REAR Caterpillar parts
D6K, D6K LGP, D6K XL, PL61
Rating:
Alternative (cross code) number:
CA2612083
261-2083
2612083
CA2612083
261-2083
2612083
Weight: 20 pounds 9 kg.
PIPELAYER, TRACK-TYPE TRACTOR,
Compare Prices:
As an associate, we earn commssions on qualifying purchases through the links below
Compatible equipment models: 2612083:
Caterpillar parts catalog:
Information:
Air Shutoff
Programming the parameter to "DISABLED" will disable the air shutoff. This parameter should be programmed to "DISABLED" if the function is not being used or installed on this engine. The disabling will prevent air shutoff diagnostics from being logged.
Table 9
Minimum     Default     Maximum    
Disabled     Enabled     Enabled    Fuel Ratio Control
The ECM determines the offset value for the Fuel Ratio Control (FRC). The FRC Offset value is used to adjust the fuel ratio control. The offset minimizes the exhaust smoke when the engine is accelerated.An offset value of 25 kPa ( 4 psi) may be used for adjusting customer preference, fuel quality, or other factors that affect engine performance. The default setting is 0.Note: This parameter may not be available on all applications. This parameter is used in place of the mechanical control for the fuel to air ratio. This parameter improves the engine response with improved emission levels.
Table 10
Minimum     Default     Maximum    
-25     0     25    Ether Control
Programming this parameter to "DISABLED" will disable the Ether functions. This parameter should be programmed to "DISABLED" if the Ether function is not being used or installed on this engine. The disabling will prevent the diagnostic codes for the ether control from being logged.
Table 11
Minimum     Default     Maximum    
Disabled     Disabled     Enabled    "CCM Interface"
The interface will allow you to control the engine from a remote site.
Table 12
Minimum     Default     Maximum    
Engine Control 1     Engine Control 1     Engine Control 8    Engine Cooling System
The engine can use the separate circuit aftercooler system (SCAC). The engine can use the jacket water aftercooler (JWAC).
Table 13
Minimum     Default     Maximum    
SCAC     SCAC     JWAC    Cold Mode Cylinder Cutout
This parameter provides the strategy for the cold mode cylinder cutout.
Table 14
Minimum     Default     Maximum    
Disabled     Enabled     Enabled    Fuel Position Multiplier
This parameter decreases the power output from the engine by reducing the fuel. This parameter is used to control the driven equipment. A decrease in engine power does not require a change in the throttle.
Table 15
Minimum     Default     Maximum    
Disabled     Enabled     Enabled    Engine Acceleration Rate
This parameter limits the rate of change for the desired engine speed. This parameter may also help reduce smoke when you start the engine.
Table 16
Minimum     Default     Maximum    
1 rpm / sec.     250 rpm / sec.     2000 rpm / sec.    Programmable Operator Switch
The "Programmable Operator Switch" parameter is used to determine the input for the ECM terminal J1-61. The parameter can be programmed to "Overspeed Verify" or to "Programmable Torque Limit".Overspeed Verify
The "Overspeed Verify" setpoint is set to 75 percent of rated speed. The "Overspeed Verify" feature can be initiated in the Cat ET "Override" screen. When the engine rpm reaches the setpoint, the normal overspeed strategy is initiated. Fueling is disabled
Programming the parameter to "DISABLED" will disable the air shutoff. This parameter should be programmed to "DISABLED" if the function is not being used or installed on this engine. The disabling will prevent air shutoff diagnostics from being logged.
Table 9
Minimum     Default     Maximum    
Disabled     Enabled     Enabled    Fuel Ratio Control
The ECM determines the offset value for the Fuel Ratio Control (FRC). The FRC Offset value is used to adjust the fuel ratio control. The offset minimizes the exhaust smoke when the engine is accelerated.An offset value of 25 kPa ( 4 psi) may be used for adjusting customer preference, fuel quality, or other factors that affect engine performance. The default setting is 0.Note: This parameter may not be available on all applications. This parameter is used in place of the mechanical control for the fuel to air ratio. This parameter improves the engine response with improved emission levels.
Table 10
Minimum     Default     Maximum    
-25     0     25    Ether Control
Programming this parameter to "DISABLED" will disable the Ether functions. This parameter should be programmed to "DISABLED" if the Ether function is not being used or installed on this engine. The disabling will prevent the diagnostic codes for the ether control from being logged.
Table 11
Minimum     Default     Maximum    
Disabled     Disabled     Enabled    "CCM Interface"
The interface will allow you to control the engine from a remote site.
Table 12
Minimum     Default     Maximum    
Engine Control 1     Engine Control 1     Engine Control 8    Engine Cooling System
The engine can use the separate circuit aftercooler system (SCAC). The engine can use the jacket water aftercooler (JWAC).
Table 13
Minimum     Default     Maximum    
SCAC     SCAC     JWAC    Cold Mode Cylinder Cutout
This parameter provides the strategy for the cold mode cylinder cutout.
Table 14
Minimum     Default     Maximum    
Disabled     Enabled     Enabled    Fuel Position Multiplier
This parameter decreases the power output from the engine by reducing the fuel. This parameter is used to control the driven equipment. A decrease in engine power does not require a change in the throttle.
Table 15
Minimum     Default     Maximum    
Disabled     Enabled     Enabled    Engine Acceleration Rate
This parameter limits the rate of change for the desired engine speed. This parameter may also help reduce smoke when you start the engine.
Table 16
Minimum     Default     Maximum    
1 rpm / sec.     250 rpm / sec.     2000 rpm / sec.    Programmable Operator Switch
The "Programmable Operator Switch" parameter is used to determine the input for the ECM terminal J1-61. The parameter can be programmed to "Overspeed Verify" or to "Programmable Torque Limit".Overspeed Verify
The "Overspeed Verify" setpoint is set to 75 percent of rated speed. The "Overspeed Verify" feature can be initiated in the Cat ET "Override" screen. When the engine rpm reaches the setpoint, the normal overspeed strategy is initiated. Fueling is disabled
Parts guard Caterpillar catalog:
2493191
GUARD GP-FUEL TANK
D6K LGP, PL61
D6K LGP, PL61
3486866
GUARD AR-BOTTOM
D6K LGP
D6K LGP
2898302
GUARD GP-LINES
D6K LGP
D6K LGP
3486853
GUARD GP-RADIATOR
D6K LGP, PL61
D6K LGP, PL61
2398217
GUARD GP-SPROCKET
D6K, D6K LGP, PL61
D6K, D6K LGP, PL61
3416562
GUARD GP-RADIATOR
D6K XL
D6K XL
2464311
GUARD
120M, 12M, 140M, 14M, 160M, 16M, 24M, 572R II, 583T, 587T, 613G, 621G, 621H, 621K, 623G, 623H, 623K, 623K LRC, 627G, 627H, 627K, 627K LRC, 631G, 637G, 657G, 966H, C9, CX31-C18I, CX35-C18I, D10T, D10T2...
120M, 12M, 140M, 14M, 160M, 16M, 24M, 572R II, 583T, 587T, 613G, 621G, 621H, 621K, 623G, 623H, 623K, 623K LRC, 627G, 627H, 627K, 627K LRC, 631G, 637G, 657G, 966H, C9, CX31-C18I, CX35-C18I, D10T, D10T2...
2622925
GUARD AS
D3K XL, D4K XL, D5K LGP, D6K LGP
D3K XL, D4K XL, D5K LGP, D6K LGP
2637360
GUARD AS
D3K XL, D4K XL, D5K LGP, D6K LGP
D3K XL, D4K XL, D5K LGP, D6K LGP
2612082
GUARD AS-REAR
D6K, D6K LGP, D6K XL, PL61
D6K, D6K LGP, D6K XL, PL61
2151574
GUARD AS
D6K, D6K LGP, D6K XL, PL61
D6K, D6K LGP, D6K XL, PL61
3826544
GUARD AS
D6K LGP, D6K2, D6K2 LGP
D6K LGP, D6K2, D6K2 LGP
3847359
GUARD AS
D6K LGP
D6K LGP
3847360
GUARD AS
D6K LGP
D6K LGP
2678655
GUARD AS-FRONT
D3K XL, D4K XL, D5K LGP, D6K LGP
D3K XL, D4K XL, D5K LGP, D6K LGP
3486852
GUARD AS
D6K LGP, PL61
D6K LGP, PL61
2863433
GUARD AS
D6K, D6K LGP, PL61
D6K, D6K LGP, PL61
2902457
GUARD AS
D6K LGP
D6K LGP
3847393
GUARD AS
D6K LGP, D6K2, D6K2 LGP
D6K LGP, D6K2, D6K2 LGP
3847392
GUARD AS
D6K LGP, D6K2, D6K2 LGP
D6K LGP, D6K2, D6K2 LGP
3826506
GUARD AS
D6K LGP, D6K2, D6K2 LGP, PL61
D6K LGP, D6K2, D6K2 LGP, PL61
3826505
GUARD AS
D6K LGP, D6K2, D6K2 LGP, PL61
D6K LGP, D6K2, D6K2 LGP, PL61
2151574
GUARD AS
D6K, D6K LGP, D6K XL, PL61
D6K, D6K LGP, D6K XL, PL61
2612082
GUARD AS-REAR
D6K, D6K LGP, D6K XL, PL61
D6K, D6K LGP, D6K XL, PL61