3237108 GUARD GP Caterpillar parts
C2.2
Rating:
Alternative (cross code) number:
CA3237108
323-7108
3237108
CA3237108
323-7108
3237108
GENERATOR SET,
Compatible equipment models: 3237108:
Information:
Illustration 1 g01984955
Schematic of the Solenoid Valve (Pump Control)This diagnostic code is associated with the Solenoid Valve (Pump Control). The FMI 03 diagnostic code means that the Implement ECM has determined that the voltage of the solenoid circuit is above normal. The possible causes of the diagnostic code are listed below:
The solenoid has failed.
The energize circuit of the solenoid is shorted to the +battery circuit.
The ECM has failed. This failure is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0499 FMI 03 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:The Implement pump will produce maximum flow. The implements may be jerky. Fuel economy will be reduced. Oil temperatures may be higher.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the ECM.
At the machine harness connector for the ECM, measure the resistance from contact J1-65 (wire H707-YL) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J1-65 (H707-YL) and the circuit that has a low resistance measurement. Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 0499 FMI 03 diagnostic code is active.Expected Result:The CID 0499 FMI 03 diagnostic code is active.Results:
YES - The CID 0499 FMI 03 diagnostic code is active. The problem has not been corrected. The ECM may have failed.Repair: Failure of the ECM is unlikely. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the Implement ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOP
NO - The CID 0499 FMI 03 diagnostic code is not active. The problem does not exist at this time.Repair: The initial diagnostic code was likely caused by a poor electrical connection or a short at one of the harness connectors that was disconnected. Resume normal machine operation.STOP
Caterpillar SIS machinery equipment:
Parts guard Caterpillar catalog:
2626540
GUARD GP
C2.2
C2.2
2626541
GUARD GP-RADIATOR
C1.5, C2.2
C1.5, C2.2
2630315
GUARD GP
C2.2, C3.3
C2.2, C3.3
3144793
GUARD GP-EXHAUST
C1.5, C2.2
C1.5, C2.2
2626538
GUARD-RADIATOR
C1.5, C2.2
C1.5, C2.2
3347304
GUARD-FAN
C1.5, C2.2
C1.5, C2.2
2921988
GUARD
3011C, 3013C, 3024C, C1.1, C1.5, C2.2
3011C, 3013C, 3024C, C1.1, C1.5, C2.2
3662656
GUARD AS-FAN
C1.5, C2.2
C1.5, C2.2
3424368
GUARD-FAN
C2.2
C2.2
3039145
GUARD GP-TRACK GUIDE
320D, 320D FM, 320D FM RR
320D, 320D FM, 320D FM RR
3826034
GUARD GP-BELT
3508C
3508C
1185099
GUARD AR
307, 307B
307, 307B
3783791
GUARD GP-TRACK ROLLER
D6T LGP, D6T LGPPAT, D6T XL
D6T LGP, D6T LGPPAT, D6T XL
2Q7053
GUARD AS
836
836
9D4150
GUARD GP-DRIVE SHAFT
776, 777
776, 777
1165516
GUARD GP-BELT
3406B, 3406C, G3406
3406B, 3406C, G3406