4240801 GUARD AS Caterpillar parts
D6R II, D6R III, D6T
Rating:
Alternative (cross code) number:
CA4240801
424-0801
4240801
CA4240801
424-0801
4240801
Weight: 9 pounds 4 kg.
TRACK-TYPE TRACTOR,
Information:
new Cat products are now using maintenance-free batteries. These batteries require different test procedures from conventional batteries. Since there are no vent plugs on maintenance-free batteries, there is no way to check the specific gravity of the electrolyte. A hydrometer cannot be used. Instead, the voltage of the battery must be checked to determine the state of charge.
Measure the open circuit voltage of the battery. Use a digital volt meter such as 6V7070 Multimeter Group. Set the meter on the 20 volt DC scale and touch the probes to the battery terminals. If the battery voltage is 12.40 or above, the battery is ready for use. If below 12.40 volts, it must be recharged for satisfactory performance.
If a maintenance-free battery is being considered for warranty, the same voltage check must be done before performing a load test. Maintenance-free batteries below 12.40 volts will fail a load test, but still may be good, serviceable batteries when recharged.
When maintenance-free batteries are deeply discharged, they may not recharge if you just jump-start the engine. Cat alternators produce 13.8 volts on 12 volt products and 27.5 volts on 24 volt products. But 16 volts (32 volts on 24 volt systems) may be required for charging to begin. Recharge with a battery charger capable of supplying 16 volts so that the batteries will accept a charge. Once they accept charging current, indicated by an increase in the charger ammeter reading, the voltage must then be reduced. It is important not to let the charging voltage exceed 16.0 volts, especially as the battery becomes fully charged.
The Cat maintenance-free battery used in original equipment (3T5760) is designed and built to rigid Cat specifications. It can be deeply discharged, such as by leaving the lights on over a weekend, and still be a good serviceable battery when fully recharged. For complete testing and charging information, refer to Special Instruction, Form SEHS7633, "Battery Test Procedure."
Measure the open circuit voltage of the battery. Use a digital volt meter such as 6V7070 Multimeter Group. Set the meter on the 20 volt DC scale and touch the probes to the battery terminals. If the battery voltage is 12.40 or above, the battery is ready for use. If below 12.40 volts, it must be recharged for satisfactory performance.
If a maintenance-free battery is being considered for warranty, the same voltage check must be done before performing a load test. Maintenance-free batteries below 12.40 volts will fail a load test, but still may be good, serviceable batteries when recharged.
When maintenance-free batteries are deeply discharged, they may not recharge if you just jump-start the engine. Cat alternators produce 13.8 volts on 12 volt products and 27.5 volts on 24 volt products. But 16 volts (32 volts on 24 volt systems) may be required for charging to begin. Recharge with a battery charger capable of supplying 16 volts so that the batteries will accept a charge. Once they accept charging current, indicated by an increase in the charger ammeter reading, the voltage must then be reduced. It is important not to let the charging voltage exceed 16.0 volts, especially as the battery becomes fully charged.
The Cat maintenance-free battery used in original equipment (3T5760) is designed and built to rigid Cat specifications. It can be deeply discharged, such as by leaving the lights on over a weekend, and still be a good serviceable battery when fully recharged. For complete testing and charging information, refer to Special Instruction, Form SEHS7633, "Battery Test Procedure."
Caterpillar parts catalog:
Parts guard Caterpillar catalog:
3497409
GUARD
D6T
D6T
2881759
GUARD
D6T
D6T
2881760
GUARD
D6T
D6T
3497410
GUARD
D6T
D6T
2901398
GUARD AS
D6T
D6T
2901400
GUARD AS
D6T
D6T
2804160
GUARD AS
D6T, D6T LGP, D6T XL
D6T, D6T LGP, D6T XL
3W1357
GUARD AS
D6H, D6H XR, D6R, D6R II, D6T
D6H, D6H XR, D6R, D6R II, D6T
2406267
GUARD
D5N, D6T
D5N, D6T
2406268
GUARD
D5N, D6T
D5N, D6T
1690162
GUARD
572R, 572R II, D7R, D7R II, D7R XR
572R, 572R II, D7R, D7R II, D7R XR
1690161
GUARD
572R, 572R II, D7R, D7R II, D7R XR
572R, 572R II, D7R, D7R II, D7R XR
1110446
GUARD AS
572R, D7H, D7R
572R, D7H, D7R
1638686
GUARD
572R, 572R II, D7R, D7R II, D7R XR
572R, 572R II, D7R, D7R II, D7R XR
1110423
GUARD AS
572R, D7H, D7R, D7R XR
572R, D7H, D7R, D7R XR
1110416
GUARD AS
572R, D7H, D7R
572R, D7H, D7R
1834503
GUARD AS
D6R II, D8R, D8R II
D6R II, D8R, D8R II
2134504
GUARD AS
D6R, D6R II, D6R III, D6T, D7E, D7E LGP, D7R II, D8R, D8R II, D8T
D6R, D6R II, D6R III, D6T, D7E, D7E LGP, D7R II, D8R, D8R II, D8T
1149363
GUARD AS
572R II, D10R, D10T, D11R, D6R II, D6R III, D6T, D7R, D7R II, D8N, D8R, D8R II, D8T, D9R, D9T
572R II, D10R, D10T, D11R, D6R II, D6R III, D6T, D7R, D7R II, D8N, D8R, D8R II, D8T, D9R, D9T
2504046
GUARD GP-ALTERNATOR
D6R II, D7R II, D8R II
D6R II, D7R II, D8R II
2151490
GUARD AS
D6R II, D6R III, D6T
D6R II, D6R III, D6T
4240802
GUARD AS
D6R II, D6R III, D6T
D6R II, D6R III, D6T