GUARD GP-BELT 4935296 - Caterpillar



4935296 GUARD GP-BELT Caterpillar parts
Rating:
56
Alternative (cross code) number:
CA4935296
493-5296
4935296
Caterpillar 4935296 GUARD GP-BELT

Buy GUARD GP-BELT 4935296 Caterpillar genuine, new aftermarket tractor parts with delivery

Compare Prices:

As an associate, we earn commssions on qualifying purchases through the links below
$35.91
 

05 Oct 2023

US: Crip Warehouse✅
177-VH550 Master Industrial Tool 4935296#1 Tors Power Bit 6" 10 Pack
Generic GenuineBranded Like on photo. Premium Quality. Usefull and rare
Number on catalog scheme:
  For full view, you need register

Caterpillar SIS machinery equipment:

Caterpillar SIS
3512B Generator Set 9G500001-UP » 493-5296 GUARD GP-BELT
3512B Generator Set 9G800001-UP » 493-5296 GUARD GP-BELT
3512C Generator Set 9H200001-UP » 493-5296 GUARD GP-BELT
3516E Generator Set JH800001-UP » 493-5296 GUARD GP-BELT
3512 Generator Set PLA00001-UP » 493-5296 GUARD GP-BELT
3512 Generator Set PLJ00001-UP » 493-5296 GUARD GP-BELT
3512B Generator Set PK200001-UP » 493-5296 GUARD GP-BELT
3512B Generator Set 7TN00001-UP » 493-5296 GUARD GP-BELT
3512C Generator Set PFP00001-UP » 493-5296 GUARD GP-BELT
3512C Generator Set PNN00001-UP » 493-5296 GUARD GP-BELT
3512B Generator Set PPA00001-UP » 493-5296 GUARD GP-BELT
3512B Generator Set PPE00001-UP » 493-5296 GUARD GP-BELT
3512C Generator Set PPL00001-UP » 493-5296 GUARD GP-BELT
3516B Generator Set PYL00001-UP » 493-5296 GUARD GP-BELT
3516B Generator Set PWL00001-UP » 493-5296 GUARD GP-BELT
3512C Generator Set LYP00001-UP » 493-5296 GUARD GP-BELT
3516B Generator Set LNW00001-UP » 493-5296 GUARD GP-BELT
3516B Generator Set LNZ00001-UP » 493-5296 GUARD GP-BELT
3512 Generator Set LNF00001-UP » 493-5296 GUARD GP-BELT
3512B Generator Set LNM00001-UP » 493-5296 GUARD GP-BELT
3516C Generator Set LY500001-UP » 493-5296 GUARD GP-BELT
3516C Generator Set LYM00001-UP » 493-5296 GUARD GP-BELT
3516E Generator Set GWZ00001-UP » 493-5296 GUARD GP-BELT
3512B Generator Set LY800001-UP » 493-5296 GUARD GP-BELT
3516C Generator Set GBZ00001-UP » 493-5296 GUARD GP-BELT
3512 Generator Set LY700001-UP » 493-5296 GUARD GP-BELT
3512B Flex Fuel Engine PPH00001-UP » 493-5296 GUARD GP-BELT
3512B Generator Set LY900001-UP » 493-5296 GUARD GP-BELT
3516B Generator Set FF200001-UP » 493-5296 GUARD GP-BELT
3516B Generator Set F4H00001-UP » 493-5296 GUARD GP-BELT
3516B Petroleum Offshore Electric Drilling Engine 9F200001-UP » 493-5296 GUARD GP-BELT
3516C Generator Set PXY00001-UP » 493-5296 GUARD GP-BELT
3516 Industrial Engine 27Z00650-00791 » 493-5296 GUARD GP-BELT
3508 Industrial Engine 95Y01065-UP » 493-5296 GUARD GP-BELT
3508 Industrial Engine 68Z01093-UP » 493-5296 GUARD GP-BELT
3512 Industrial Engine 65Z00887-UP » 493-5296 GUARD GP-BELT
3516 Industrial Engine 27Z00792-UP » 493-5296 GUARD GP-BELT
3512 Generator Set LDB00001-UP » 493-5296 GUARD GP-BELT
3512C Industrial Engine PE400001-UP » 493-5296 GUARD GP-BELT
3512B Marine Auxiliary Engine ED300001-UP » 493-5296 GUARD GP-BELT
3512B Generator Set ED500001-UP » 493-5296 GUARD GP-BELT
3512C Marine Auxiliary Engine ED400001-UP » 493-5296 GUARD GP-BELT
3512 Petroleum Engine LN200001-UP » 493-5296 GUARD GP-BELT
3512 Petroleum Engine LN300001-UP » 493-5296 GUARD GP-BELT
3512B Petroleum Engine LN400001-UP » 493-5296 GUARD GP-BELT
3512C Petroleum Engine LN500001-UP » 493-5296 GUARD GP-BELT
3516B Petroleum Engine EDJ00001-UP » 493-5296 GUARD GP-BELT
3516 Generator Set LD500001-UP » 493-5296 GUARD GP-BELT
3508B Industrial Engine LD700001-UP » 493-5296 GUARD GP-BELT
3508 Industrial Engine LDP00001-UP » 493-5296 GUARD GP-BELT
3508 Industrial Engine LDW00001-UP » 493-5296 GUARD GP-BELT
3512 Industrial Petroleum PE200001-UP » 493-5296 GUARD GP-BELT
3512 Industrial Petroleum PE300001-UP » 493-5296 GUARD GP-BELT
3512C Petroleum Engine LD900001-UP » 493-5296 GUARD GP-BELT
3512B Petroleum Generator Set FFS00001-UP » 493-5296 GUARD GP-BELT
3516 Generator Set JCG00001-UP » 493-5296 GUARD GP-BELT
3516B Generator Set JCH00001-UP » 493-5296 GUARD GP-BELT
3516B Generator Set JCN00001-UP » 493-5296 GUARD GP-BELT
3512 Generator Set JM200001-UP » 493-5296 GUARD GP-BELT
3512B Generator Set JM300001-UP » 493-5296 GUARD GP-BELT
3512B Generator Set JM400001-UP » 493-5296 GUARD GP-BELT
3512C Petroleum Generator Set 9G900001-UP » 493-5296 GUARD GP-BELT
3512B Petroleum Generator Set FFY00001-UP » 493-5296 GUARD GP-BELT
3512C Petroleum Generator Set LM900001-UP » 493-5296 GUARD GP-BELT


Information:


Illustration 1 g00387727
Schematic of the Detent Coil (Lift Lever Raise)
This diagnostic code is associated with the Detent Coil (Lift Lever Raise). The FMI 03 means that the ECM has determined that the voltage of the solenoid circuit is above normal. The possible causes of the diagnostic code are listed:
The solenoid has failed.
The energize circuit of the solenoid is shorted to the +battery circuit.
The ECM has failed. This is unlikely.Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected. Ensure that the diagnostic code of CID 0359 FMI 03 is active before performing this procedure.Note: Use the 146-4080 Digital Multimeter for the measurements in this procedure.System Response:The lift lever will not release from the RAISE detent position. After the lift kickout is completed, the lift lever must be recentered in order to allow the lift linkage to move.Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT TO THE +BATTERY CIRCUIT.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness connectors from the solenoid and the ECM.
At the machine harness connector for the ECM, measure the resistance from contact J1-18 (wire H719-OR(Orange)) to all contacts that are used in the machine harness connectors for the ECM. Expected Result:Each resistance measurement is greater than 5000 ohms. Results:
OK - Each resistance measurement is greater than 5000 ohms. The machine harness is correct. Proceed to Test Step 2.
NOT OK - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness. The short is between J1-18 (H719-OR(Orange)) and the circuit that has a low resistance measurement. Repair: Repair the machine harness or replace the machine harness.STOPTest Step 2. CHECK IF THE DIAGNOSTIC CODE IS STILL ACTIVE.
Inspect the contacts and clean the contacts of the harness connectors.
Reconnect all harness connectors.
Turn the disconnect switch and the key start switch to the ON position.
Operate the machine.
Determine if the CID 0359 FMI 03 is active. Expected Result:The CID 0359 FMI 03 is active.Results:
YES - The CID 0359 FMI 03 is active. The problem has not been corrected. The ECM may have failed.Repair: It is unlikely that the ECM has failed. Exit this procedure and perform this procedure again. If the cause of the diagnostic code is not found, replace the ECM. See Testing and Adjusting, "Electronic Control Module (ECM) - Replace".STOP
NO - The CID 0359 FMI 03 is not active. The problem does not exist at this time.Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP