Illustration 1 g01445763
PMPE Generator Wiring Diagram (1) Voltage regulator and/or related components (CR1-CR6) Diodes (CR7) Varistor (L1) Exciter field (stator) (L2) Exciter armature (rotor) (L3) Main field (rotor) (L4) Main armature (stator) (L5) Pilot exciter armature (PM) Permanent magnet (RFA) Rotating field assembly (CST) Customer supplied transformer
Table 1
Tools Needed    
Part Number     Part (1)     Quantity    
6V-7070     Digital Multimeter     1    
146-4080     Digital Multimeter (RS232)     1    
( 1 ) Only one multimeter is necessary for this test. Either of the multimeters that are shown will work.
The high voltage that is produced by an operating generator set can cause severe injury or death. Before performing any maintenance or repairs, ensure that the generator will not start.Place the engine control switch in the "OFF" position. Attach "DO NOT OPERATE" tags to all starting controls. Disconnect the batteries or disable the starting system. Lock out all switchgear and automatic transfer switches that are associated with the generator.
Measure the resistance of the following windings: (L1), (L2), (L3), (L4) and (L5). The winding that is being tested must be disconnected from the other components before the resistance can be measured. The following resistance measurements are approximations. If the measured value is not near the listed approximation, the winding is probably damaged. For a more precise resistance value, consult the Technical Marketing Information (TMI). Refer to the generator arrangement that is in question.Note: The winding temperature affects the resistance. When the winding temperature increases, the winding resistance also increases. When the winding temperature decreases, the winding resistance also decreases. Therefore, a correct measurement can be performed only when the winding is at room temperature.The following armature windings have little resistance: (L2), (L4) and (L5). The resistance of these windings will measure near 0 ohms. Use a milliohmmeter to measure the resistance of the armature windings.Exciter Armature (Rotor) (L2) - less than 0.1 ohmMain armature (Stator) (L4) - less than 0.1 ohmPilot Exciter Armature (L5) - less than 0.1 ohmUse a multimeter in order to measure the resistance of field windings (L1) and (L3) .E
Caterpillar parts catalog:
Parts guard Caterpillar catalog:
3K3420
GUARD AS
941, 951B, 955H, D4D, D4E, D4E SR
941, 951B, 955H, D4D, D4E, D4E SR
3K9249
GUARD
941, D4D, D4E, D4E SR
941, D4D, D4E, D4E SR
3V3552
GUARD AS
D4D, D4E, D4E SR
D4D, D4E, D4E SR
3V3484
GUARD AS
D4D, D4E, D4E SR
D4D, D4E, D4E SR
5K3419
GUARD AS-SCREW
D4D, D4E, D4E SR
D4D, D4E, D4E SR
5K3420
GUARD AS-SCREW
D4D, D4E, D4E SR
D4D, D4E, D4E SR
4K5549
GUARD
D4D, D4E, D4E SR
D4D, D4E, D4E SR
7K3711
GUARD ASSEM. (Front-Outer)
951B, 955K, 955L
951B, 955K, 955L
7K2944
GUARD ASSEM. (Front-L.H.)
941, D4D, D4E, D4E SR
941, D4D, D4E, D4E SR
7K2943
GUARD ASSEM. (Front-R.H.)
941, D4D, D4E, D4E SR
941, D4D, D4E, D4E SR
4F8396
GUARD
941, 951B, 955C, D4D, D4E, D4E SR
941, 951B, 955C, D4D, D4E, D4E SR
3F1530
GUARD
941, 951B, 955C, D4D, D4E, D4E SR
941, 951B, 955C, D4D, D4E, D4E SR
1137885
GUARD
D4E SR
D4E SR
1137886
GUARD
D4E SR
D4E SR
2P4333
GUARD AS-FAN-LH
D4D, D4E, D4E SR
D4D, D4E, D4E SR
2P4332
GUARD AS-FAN-RH
D4D, D4E, D4E SR
D4D, D4E, D4E SR
2Y8210
GUARD AS
D4E, D4E SR
D4E, D4E SR
7K3005
GUARD-TRACK GUIDE
941, D4D, D4E, D4E SR
941, D4D, D4E, D4E SR
1109161
GUARD AS-RADIATOR
D4E SR
D4E SR
1108298
GUARD AS-PULLEY
D4E SR
D4E SR
7V6577
GUARD AS
D4E, D4E SR
D4E, D4E SR
1108293
GUARD AS-FRONT
D4E SR
D4E SR