5K7141 GUARD ASSEM. Caterpillar parts
D4D
Rating:
Alternative (cross code) number:
CA5K7141
5K-7141
5K7141
CA5K7141
5K-7141
5K7141
Weight: 20 pounds 9 kg.
TRACK-TYPE TRACTOR,
Compare Prices: .
As an associate, we earn commssions on qualifying purchases through the links below
$70.76
30 Oct 2021
Amazon.com
CTP 5K7141 Guard for Model D4D for Heavy Equipment
CTP For Model D4D || Sold in each || Easy in-and-out fit
CTP For Model D4D || Sold in each || Easy in-and-out fit
Compatible equipment models: 5K7141:
Information:
The "Digital Input Configurations" should be verified. Once verified, the "Digital Input Configurations" should be changed if required. These values are used to configure the digital sensors "#1", "#2", "#3", and "#4" of the Product Link system. Refer to Systems Operation, Troubleshooting, Testing and Adjusting, "Spare Inputs" for an example of types of switches. Refer to the Systems Operation, Troubleshooting, Testing and Adjusting, "System Schematic" for an example of a wiring diagram for the inputs.Note: The following information is applicable to all four of the digital inputs."Digital Input Configuration"
Illustration 1 g01361917
"Digital Input Configuration" Screen
Table 1
Digital Input 1, 2, 3, or 4
Sensor Definition Configuration Notes
"Digital Sensor Input 1, 2, 3, or 4 Configuration Type" The "Digital Sensor Input 1, 2, 3, or 4 Configuration Type" parameter defines whether a sensor is attached and, if attached, the state of the switch contacts under normal operating conditions (Normally Open or Normally Closed). "Not Installed": The user cannot set the sensor to "Not Installed". No sensor attached to the input.
The user can set the type of sensor by the following methods:
"Not Configured": Sensor may be attached to the input but not in use.
"Normally Closed": Sensor is at a closed (or low) state under normal operating conditions.
"Normally Open": Sensor is at an open (or high) state under normal operating conditions. The user cannot set the sensor to "Not Installed". "Not Installed" is the factory default.
"Digital Input 1, 2, 3, or 4 Monitoring Condition" Defines the monitoring condition for the digital input. If the digital input is in the alarm state (opposite the normal state) as specified in "Digital Sensor Input 1, 2, 3, or 4 Type Configuration", for the delay time specified in "Digital Sensor Input 1, 2, 3, or 4 Delay Time", while the "Digital Input 1, 2, 3, or 4 Monitoring Condition" is true, an event is recorded and sent to the Equipmentmanager application. Set for the desired monitoring condition as follows:
All Conditions: Will monitor input without regard to key position or engine status.
Key Off/Engine Off. Will monitor the digital input when key is OFF and engine is not running.
Key On/Engine OFF: Will monitor the digital input when key is ON and engine is not running.
Key On/Engine On: Will monitor input when key is ON and engine is running. "All Conditions" is the factory default.
With key Off/Engine Off, status changes will only be monitored when the PL300 wakes up for scheduled reports. An Input on these switches will not trigger the PL300 to “wake up”.
"Digital Sensor Input 1, 2, 3, or 4 Description" The "Digital Sensor Input 1, 2, 3, or 4 Description" parameter is a 24 character field used to describe what the sensor is monitoring. This value is used in the office software to display the sensor status. Enter a maximum of 24 characters for the description of the digital sensor input, for example "TRACK TENSION SENSOR". The default is "DIGITAL INPUT 1, 2, 3, or 4".
"Digital Sensor Input 1, 2, 3, or 4 Delay Time" Defines the delay time
Illustration 1 g01361917
"Digital Input Configuration" Screen
Table 1
Digital Input 1, 2, 3, or 4
Sensor Definition Configuration Notes
"Digital Sensor Input 1, 2, 3, or 4 Configuration Type" The "Digital Sensor Input 1, 2, 3, or 4 Configuration Type" parameter defines whether a sensor is attached and, if attached, the state of the switch contacts under normal operating conditions (Normally Open or Normally Closed). "Not Installed": The user cannot set the sensor to "Not Installed". No sensor attached to the input.
The user can set the type of sensor by the following methods:
"Not Configured": Sensor may be attached to the input but not in use.
"Normally Closed": Sensor is at a closed (or low) state under normal operating conditions.
"Normally Open": Sensor is at an open (or high) state under normal operating conditions. The user cannot set the sensor to "Not Installed". "Not Installed" is the factory default.
"Digital Input 1, 2, 3, or 4 Monitoring Condition" Defines the monitoring condition for the digital input. If the digital input is in the alarm state (opposite the normal state) as specified in "Digital Sensor Input 1, 2, 3, or 4 Type Configuration", for the delay time specified in "Digital Sensor Input 1, 2, 3, or 4 Delay Time", while the "Digital Input 1, 2, 3, or 4 Monitoring Condition" is true, an event is recorded and sent to the Equipmentmanager application. Set for the desired monitoring condition as follows:
All Conditions: Will monitor input without regard to key position or engine status.
Key Off/Engine Off. Will monitor the digital input when key is OFF and engine is not running.
Key On/Engine OFF: Will monitor the digital input when key is ON and engine is not running.
Key On/Engine On: Will monitor input when key is ON and engine is running. "All Conditions" is the factory default.
With key Off/Engine Off, status changes will only be monitored when the PL300 wakes up for scheduled reports. An Input on these switches will not trigger the PL300 to “wake up”.
"Digital Sensor Input 1, 2, 3, or 4 Description" The "Digital Sensor Input 1, 2, 3, or 4 Description" parameter is a 24 character field used to describe what the sensor is monitoring. This value is used in the office software to display the sensor status. Enter a maximum of 24 characters for the description of the digital sensor input, for example "TRACK TENSION SENSOR". The default is "DIGITAL INPUT 1, 2, 3, or 4".
"Digital Sensor Input 1, 2, 3, or 4 Delay Time" Defines the delay time
Caterpillar parts catalog:
Parts guard Caterpillar catalog:
2P4331
GUARD AS-FAN
D4D, D4E, D4E SR
D4D, D4E, D4E SR
3F1530
GUARD
941, 951B, 955C, D4D, D4E, D4E SR
941, 951B, 955C, D4D, D4E, D4E SR
4F8396
GUARD
941, 951B, 955C, D4D, D4E, D4E SR
941, 951B, 955C, D4D, D4E, D4E SR
4F6029
GUARD
941, 951B, 955C, D4D, D4E, D4E SR
941, 951B, 955C, D4D, D4E, D4E SR
7K3005
GUARD-TRACK GUIDE
941, D4D, D4E, D4E SR
941, D4D, D4E, D4E SR
3K3420
GUARD AS
941, 951B, 955H, D4D, D4E, D4E SR
941, 951B, 955H, D4D, D4E, D4E SR
3K9249
GUARD
941, D4D, D4E, D4E SR
941, D4D, D4E, D4E SR
5K3419
GUARD AS-SCREW
D4D, D4E, D4E SR
D4D, D4E, D4E SR
5K3420
GUARD AS-SCREW
D4D, D4E, D4E SR
D4D, D4E, D4E SR
4K5549
GUARD
D4D, D4E, D4E SR
D4D, D4E, D4E SR
7K2944
GUARD ASSEM. (Front-L.H.)
941, D4D, D4E, D4E SR
941, D4D, D4E, D4E SR
1M9097
GUARD ASSEM. (Right Hand)
594, D9E, D9G, D9H
594, D9E, D9G, D9H
1M9098
GUARD ASSEM. (Left Hand)
594, D9E, D9G, D9H
594, D9E, D9G, D9H
7K2980
GUARD ASSEM.
977K
977K
5M8620
GUARD
571G
571G
5M5649
GUARD ASSEM.
571G
571G