AVSPARE.COM
parts catalog

GUARD-TRACK GUIDE 7K3005 - Caterpillar


7K3005 GUARD-TRACK GUIDE Caterpillar parts 941, D4D, D4E, D4E SR
Rating:
65
Alternative (cross code) number:
CA7K3005
7K-3005
7K3005
Caterpillar 7K3005 GUARD-TRACK GUIDE
Weight: 9 pounds 4 kg.

Buy GUARD-TRACK GUIDE 7K3005 Caterpillar genuine, new aftermarket tractor parts with delivery
TRACK LOADER, TRACK-TYPE TRACTOR,

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
$63.14

17 Mar 2025

Amazon.com
CTP 7K3005 Guard for Model 941/D4D/D4E/D4E SR
CTP For Model 941/D4D/D4E/D4E SR || Sold in each || Easy in-and-out fit || Country of origin: United States
$65.34

03 Feb 2025

Amazon.com
CTP 7K3005 Guard for Model 941/D4D/D4E/D4E SR
CTP For Model 941/D4D/D4E/D4E SR || Sold in each || Easy in-and-out fit || Country of origin: United States
$59.55

11 Jul 2024

Amazon.com
CTP 7K3005 Guard for Model 941/D4D/D4E/D4E SR
CTP For Model 941/D4D/D4E/D4E SR || Sold in each || Easy in-and-out fit || Country of origin: United States
Number on catalog scheme: 5
  For full view, you need register

Compatible equipment models: 7K3005:

TRACK LOADER  941  
TRACK-TYPE TRACTOR  D4D   D4E   D4E SR   Caterpillar

Information:

Conditions Which Generate This Code:
Illustration 1 g01238171
Schematic of the transmission oil temperature sensorThis diagnostic trouble code is recorded when the ECU reads the voltage of the temperature sensor as being below normal. The voltage of the signal wire is below normal and/or shorted to ground. The possible causes of this diagnostic trouble code are listed here:
The signal circuit in the machine harness is shorted to ground.
The sensor has failed.
The ECU has failed. The ECU failing is unlikely.Test Step 1. CHECK THE SENSOR.
Turn the disconnect switch and the key start switch to the ON position.
Observe the status of the diagnostic trouble code. Then disconnect the machine harness from the sensor.Expected Result:If the sensor is not the cause of the diagnostic trouble code, the diagnostic trouble code remains active. If the sensor has failed, the diagnostic trouble code is NO longer active.Results:
OK - The diagnostic trouble code is active. The sensor is not causing the diagnostic trouble code. The machine harness or the ECU may have failed. Proceed to test step 2.
NOT OK - This diagnostic trouble code is NO longer active. The machine harness is correct and the ECU is operating properly. The sensor has failed.Repair: Replace the sensor.STOPTest Step 2. CHECK THE SIGNAL CIRCUIT FOR A SHORT TO GROUND.
The sensor remains disconnected from the machine harness.
Turn the key start switch and the disconnect switch to the OFF position.
Disconnect the machine harness from the ECU.
At the machine harness connector for the ECU, measure the resistance between the signal contact and frame ground.Expected Result:The resistance is greater than 5.0 ohms.Results:
OK - The resistance is greater than 5.0 ohms. The harness circuit resistance is correct. Proceed to test step 3.
NOT OK - Resistance is less than 5.0 ohms. The machine harness has failed.Repair: There is a short between frame ground and the signal circuit in the machine harness. Repair the machine harness or replace the machine harness.STOPTest Step 3. CHECK IF THE DIAGNOSTIC TROUBLE CODE REMAINS.
Inspect the harness connectors. Clean the contacts of the harness connectors and check the wires for damage to the insulation that is caused by excessive heat, battery acid, or chafing.
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.
Reconnect all harness connectors. Make sure that the harness connectors are fully seated and that the clips for each connector are fastened.
Turn the disconnect switch and the key start switch to the ON position.
Operate the vehicle.
Determine if the SPN 177 FMI 4 is active.Expected Result:The diagnostic trouble code is no longer active.Results:
YES - The SPN 177 FMI 4 is not active. The diagnostic trouble code does not exist at this time. The initial diagnostic trouble code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.STOP
NO - The SPN 177 FMI 4 is active. The diagnostic trouble code has not been corrected.Repair: Check the circuit again. If the Caterpillar Electronic Technician (ET) is available,

Caterpillar parts catalog:

Caterpillar parts catalog
D4E SR Track-Type Tractor Direct Drive 2DJ01400-UP (MACHINE) POWERED BY 3304 Engine


Parts guard Caterpillar catalog:

3K3420 GUARD AS
941, 951B, 955H, D4D, D4E, D4E SR
3K9249 GUARD
941, D4D, D4E, D4E SR
3V3552 GUARD AS
D4D, D4E, D4E SR
3V3484 GUARD AS
D4D, D4E, D4E SR
5K3419 GUARD AS-SCREW
D4D, D4E, D4E SR
5K3420 GUARD AS-SCREW
D4D, D4E, D4E SR
4K5549 GUARD
D4D, D4E, D4E SR
4F6029 GUARD
941, 951B, 955C, D4D, D4E, D4E SR
4F8396 GUARD
941, 951B, 955C, D4D, D4E, D4E SR
3K9249 GUARD
941, D4D, D4E, D4E SR
3K3420 GUARD AS
941, 951B, 955H, D4D, D4E, D4E SR
Back to top
The names Cat, Caterpillar, John Deere, Komatsu, Volvo, Hitachi, Doosan, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
AVSpare.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only. Cat® and Caterpillar® are registered trademarks of Caterpillar, Inc.